Highlights
- System master clock (two-phase - 16.384 Mhz) and module reset
- Circuitry for 6 audio program feed channels
- Can be fed by any analog source
- Galvanic isolated input via 600 ohm transformer to avoid noise problems
- Adjustable sensitivity (gain)
- 6 alarm inputs
- 2 internal alarms
- Fan control
- Coded connector to ensure correct positioning in the module
- Power connector (6-pin socket source) for hot plug-in cable
- Reset button in front
Installation
The APC board is used in the AlphaCom XE20 and XE26 servers. The board plugs into board position 26
Filter Board
In the AlphaCom XE20 and XE26 exchanges a filter and connection board must be inserted from the rear side of the cabinet in the same card position as the AMC-IP card.