Actions

Difference between revisions of "APC - AlphaCom Program & Clock Board"

From Zenitel Wiki

(Filter Board)
Line 28: Line 28:
 
<br>
 
<br>
  
===Filter Board===
+
=== APC Connection Kit - 1009503000 ===
In the [[AlphaCom XE20]] and [[AlphaCom XE26|XE26 exchanges]] a [[Filter card AMC-IP|filter and connection board]] must be inserted from the rear side of the cabinet in the same card position as the AMC-IP card.
+
The APC Connection Kit consists of APC filter card and APC connection board. This kit is required to access the '''6 remote control input'''s and '''6 audio program inputs''' of the APC
  
 
<br>
 
<br>
 +
 
==Related Articles==
 
==Related Articles==
 
* [[APC Connection Kit - 1009503000]]
 
* [[APC Connection Kit - 1009503000]]

Revision as of 15:10, 31 August 2018

AlphaCom icon 300px.png
1009301000.PNG

Highlights

  • System master clock (two-phase - 16.384 Mhz) and module reset
  • Circuitry for 6 audio program feed channels
  • Can be fed by any analog source
  • Galvanic isolated input via 600 ohm transformer to avoid noise problems
  • Adjustable sensitivity (gain)
  • 6 alarm inputs
  • 2 internal alarms
  • Fan control
  • Coded connector to ensure correct positioning in the module
  • Power connector (6-pin socket source) for hot plug-in cable
  • Reset button in front


Installation

The APC board is used in the AlphaCom XE20 and XE26 servers. The board plugs into board position 26

OBS icon
  • Turn power off before inserting or removing the APC board


APC board, connection and adjustment



APC Connection Kit - 1009503000

The APC Connection Kit consists of APC filter card and APC connection board. This kit is required to access the 6 remote control inputs and 6 audio program inputs of the APC