Actions

Difference between revisions of "AlphaCom XE7"

From Zenitel Wiki

Line 6: Line 6:
 
* SIM card based software configuration and disaster recovery
 
* SIM card based software configuration and disaster recovery
 
* Fully compatible with any AlphaCom system
 
* Fully compatible with any AlphaCom system
 
===<u>[http://www.zenitel.com/product/alphacom-xe7 Additional Documentation on Zenitel.com]</u>===
 
  
 
=Board positions=
 
=Board positions=
Line 59: Line 57:
 
===Hardware Upgrade===
 
===Hardware Upgrade===
 
See [[AlphaCom Exchange Upgrade]]
 
See [[AlphaCom Exchange Upgrade]]
 +
 +
=[http://www.zenitel.com/product/alphacom-xe7 Additional Documentation on Zenitel.com]=
  
 
=Related article=
 
=Related article=

Revision as of 15:19, 4 November 2016

AlphaCom XE7 Audio Server with HD Voice

Highlights

  • Made to provide critical communication in any environment
  • Supports 552 IP stations and 36 analog intercom stations
  • SIM card based software configuration and disaster recovery
  • Fully compatible with any AlphaCom system

Board positions

Board positions and physical numbers in AlphaCom XE7


Connections

XE7 backplane1.png


  • The server is normally powered from the mains via a 24 VAC transformer. Battery backup power can be connected to the 24 VDC input plug.
  • Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming
  • All cables are terminated to connectors on the backplane. The two-pair star wired intercom cables and single-pair telephone cables are connected using pluggable screw connectors
  • Connectors 5 and 6 on the first ASLT line board are enabled for program distribution. Additional programs can be connected by substituting line boards with AGA boards with 6 programs per board
  • There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. The 12 RCOs are connected to optional MRBD relay boards and can be programmed to execute functions such as door control
  • The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
XE7 IP and serial connections


Serial Ports

Serial Port 0 - 9-Pin D-sub (RS232 Only)

No additional settings necessary

Serial Port 1 - RJ45 (RS232/422/485)

Additional settings:
RS232:
RS422:
  • Switch 8 on S601 on the AMC-IP board must be set to ON.
  • Set the two jumpers on the backplane in to the correct position.
RS422/485 selector for Serial Port 1 on the XE7 backplane


Remote Control Inputs (RCI)

  • There are two inputs for clean contacts on the RCI connectors which can execute programmable functions.
RCI inputs in an AlphaCom XE7


Remote Control Outputs (RCO)

Mounting

Factory Reset (coldstart)

Upgrade

Software upgrade

See AMC-IP software upgrade

Hardware Upgrade

See AlphaCom Exchange Upgrade

Additional Documentation on Zenitel.com

Related article