Line 19: Line 19:
  
 
At the end of the event RCO 6 is chosen as the triggered action caused by the event.
 
At the end of the event RCO 6 is chosen as the triggered action caused by the event.
 +
 +
==RCO==
 +
The actual physical output that is activated is dependant on the station type.
 +
 +
===Analogue stations===
 +
If the door station is analogue the RCO comes from the server its self. On an [XE7]] there are two connectors for RCO1-6 and 7-12 located on the back:
 +
[[File:XE7 RCO Connectors.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 +
On XE20/XE26 there is an RCO output per ASLT connection. These can be fetched either from
 +
* [[Subscriber Connection Board - 1009930200|Subscriber Connection Board]]
 +
[[File:Subscriber Connection Board RCO.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 +
* [[Filter and connection card ASLT and ATLB]]
 +
[[File:RJ45 Connection RCO.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 +
The RCO, which is a logical signal must be connected to a relay. Use the Multi Relay Board for this. See [[MRBD|MRBD article]] for further details.

Revision as of 09:25, 22 May 2015

This is an article explaining in detail how to configure Door Opening.

Door Opening is a standard feature in the AlphaCom. The way it works is that when an operator is in a conversation with a door station, the operator kan dial digit 6 to activate an RCO. The RCO will in turn activate a relay which again releases the door lock. But, for all this to happen we need to assist the server with some details.

Event Handler

We need to define who this event is for, and which output to activate. This is done using the Event Handler. Go to Exhcange&System from the top menu in AlphaPro:

AlphaPro Exchange and System icon.png


From the Exchange&System window choose the Events button:

Exchange System Events.png


In the Event Actions window click the Insert button and create an event like this:

EventHandler Event2.PNG


This event is triggered when the operator dials digit 6 while in covnersation with the door. Physical number 6 (the door station) is the owner of the event. This is where it happens. When Related To can be set to all, meaning whoever in conversation with the door is allowed to dial digit 6 to open the door. In this example we have chosen to limit this acces by selecting a single station; Directory number 120.

At the end of the event RCO 6 is chosen as the triggered action caused by the event.

RCO

The actual physical output that is activated is dependant on the station type.

Analogue stations

If the door station is analogue the RCO comes from the server its self. On an [XE7]] there are two connectors for RCO1-6 and 7-12 located on the back:

XE7 RCO Connectors.png


On XE20/XE26 there is an RCO output per ASLT connection. These can be fetched either from

Subscriber Connection Board RCO.png


RJ45 Connection RCO.png


The RCO, which is a logical signal must be connected to a relay. Use the Multi Relay Board for this. See MRBD article for further details.