Line 22: Line 22:
 
*Include operator stations in [[UDP]] group 1. Name the [[UDP]] group e.g. "Operators".
 
*Include operator stations in [[UDP]] group 1. Name the [[UDP]] group e.g. "Operators".
  
DynGrp UDP.PNG
+
[[File:DynGrp UDP.PNG|thumb|left|500px|Include the operator station in UDP Group 1, and enter the directory number of the Dynamic Group used by this operator]]
 +
<br style="clear:both;" />
 +
 
  
 
===Event Handler configuration===
 
===Event Handler configuration===

Revision as of 13:07, 27 May 2021

AlphaCom icon 300px.png

Operation

  • Press a dedicated "Group Configursation" DAK key. The red led in key starts flashing, and the Dynamic Group is emptied.
  • Select stations or local groups to be included by pressing the associated DAK keys. A steady green led in the keys indicates that the stations/groups are included
  • Press the "Group Configuration" button again, and the group call is activated (the ding-dong chime is played). Pressing the `M`-key opens the microphone.
  • The green leds continue to be lit during the group call
  • Cancel the group call by pressing the `C`-key. The green LEDs are turned off.

For best performance it is recommended to use CRM V station or ECPIR-3P panel, as these devices have buttons with LEDs showing status.

Software requirements

  • ICX: Any version
  • AlphaCom: 13.0.3.0 or later

Configuration

  • Assign directory number 9535 to DAK 1 of the operator station. This is the Group Configuration button. Directory number 9535 is included in a default database.
"Group Configuration" button


  • Each operator station is assigned its own Dynamic Group Call by entering the Dynamic Group Call number in the User Defined Parameter (%1.EXP) field of the operator.
  • Include operator stations in UDP group 1. Name the UDP group e.g. "Operators".
Include the operator station in UDP Group 1, and enter the directory number of the Dynamic Group used by this operator



Event Handler configuration

In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events:

DynGrp Event1.PNG

IF %chg(1,0) IND %1.phy 0 0 0 OFF $GRM LV L%1.exp U3 IND %1.phy %1.dak(I%2.dir) 1 3 ON ENDIF

IF %chg(0,1) IND %1.phy %1.dak(I%2.dir) 1 3 ON $ST L%1.dir W10 L%1.exp ENDIF

DynGrp Event2.PNG

IND %1.phy %1.dak(I%2.dir) 2 1 ON $GRM L%2.dir L%1.exp U1 IF %op(%2.dir,=,9535) $DISCON_ST L%1.dir 0 IND %1.phy %1.dak(I%2.dir) 2 1 OFF PAUSE PAUSE PAUSE $DD L%1.dir L%1.exp


DynGrp Event3.PNG

IF %op(%2.dir,=,%1.exp) IF %chg(1,0) $ST L%1.dir W0 L%1.exp stop ENDIF IND %1.phy 0 0 0 OFF ENDIF


DynGrp Event4.PNG

IF %op(%2.dir,=,%1.exp) IND %1.phy 0 0 0 OFF ENDIF