==Operation ==
 
==Operation ==
*Press a dedicated "Group Configursation" [[DAK]] key. The red led in key starts flashing, and the Dynamic Group is emptied.
+
For best performance it is recommended to use [[CRM_V_-_Control_Room_Master|CRM V station]] or [[ECPIR-3P|ECPIR-3P panel]], as these devices have buttons with LEDs showing status.
 +
 
 +
*Press a dedicated "Group Configuration" [[DAK]] key. The red led in key starts flashing, and the Dynamic Group is emptied.
 
*Select stations or local groups to be included by pressing the associated [[DAK]] keys. A steady green led in the keys indicates that the stations/groups are included  
 
*Select stations or local groups to be included by pressing the associated [[DAK]] keys. A steady green led in the keys indicates that the stations/groups are included  
 
*Press the "Group Configuration" button again, and the group call is activated (the ding-dong chime is played). Pressing the `M`-key opens the microphone.
 
*Press the "Group Configuration" button again, and the group call is activated (the ding-dong chime is played). Pressing the `M`-key opens the microphone.
Line 7: Line 9:
 
*Cancel the [[Groups#Group_Call.2FAnnouncements|group call]] by pressing the `C`-key. The green LEDs are turned off.
 
*Cancel the [[Groups#Group_Call.2FAnnouncements|group call]] by pressing the `C`-key. The green LEDs are turned off.
  
For best performance it is recommended to use [[CRM_V_-_Control_Room_Master|CRM V station]] or [[ECPIR-3P|ECPIR-3P panel]], as these devices have buttons with LEDs showing status.
+
{{note|One can only include, not remove, stations/groups into the dynamic group. If a wrong selection is made, press the C-key, and start the selection over again.}}
  
 
== Software requirements==
 
== Software requirements==
Line 19: Line 21:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
*Each operator station is assigned its own Dynamic Group Call by entering the Dynamic Group Call number in the User Defined Parameter (%1.EXP) field of the operator.
+
*Each operator station is assigned its own Dynamic Group Call by entering the directory number of the Dynamic Group Call in the User Defined Parameter (%1.EXP) field of the operator.
 
*Include operator stations in [[UDP]] group 1. Name the [[UDP]] group e.g. "Operators".
 
*Include operator stations in [[UDP]] group 1. Name the [[UDP]] group e.g. "Operators".
  
DynGrp UDP.PNG
+
[[File:DynGrp UDP.PNG|thumb|left|500px|Include the operator station in UDP Group 1, and enter the directory number of the Dynamic Group used by this operator (Here: 899)]]
 +
<br style="clear:both;" />
 +
 
  
 
===Event Handler configuration===
 
===Event Handler configuration===
  
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following events:
+
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press '''Insert''' and create the following events (Simply '''copy/paste''' the action strings below into AlphaPro):
  
DynGrp Event1.PNG
+
'''Event 1: Start/stop Group Configuration'''
 +
*When the "Group Configuration" button is pressed, empty the Dynamic Group and turn on red LED in the button.
 +
*When leaving the Group Configuration mode, start a 1 sec timer. If the Dynamic Group is not activated within this time, the LEDs will be cleared.
  
IF %chg(1,0)
+
[[File:DynGrp Event1.PNG|thumb|left|500px|Start/stop Group Configuration]]
IND %1.phy 0 0 0 OFF
+
<br style="clear:both;" />
$GRM LV L%1.exp U3
 
IND %1.phy %1.dak(I%2.dir) 1 3 ON
 
ENDIF
 
  
IF %chg(0,1)
+
{{Code2|
IND %1.phy %1.dak(I%2.dir) 1 3 ON
+
IF %chg(1,0)
$ST L%1.dir W10 L%1.exp
+
$GRM LV L%1.exp U3
ENDIF
+
IND %1.phy %1.dak(I%2.dir) 1 3 ON
 +
stop
 +
ENDIF
 +
$ST L%1.dir W10 L%1.exp
 +
}}
  
DynGrp Event2.PNG
+
'''Event 2: Include members'''
 +
*When DAK keys are pressed during Group Configuration mode, turn on the green LED, and include the station or local group to the dynamic group
 +
*If the DAK key pressed is the "Group Configuration" button (9535), disconnect the station from configuration mode, turn off the red LED, and dispatch the dynamic group call
  
IND %1.phy %1.dak(I%2.dir) 2 1 ON
+
[[File:DynGrp Event2.PNG|thumb|left|500px|Include members]]
$GRM L%2.dir L%1.exp U1
+
<br style="clear:both;" />
IF %op(%2.dir,=,9535)
 
$DISCON_ST L%1.dir 0
 
IND %1.phy %1.dak(I%2.dir) 2 1 OFF
 
PAUSE
 
PAUSE
 
PAUSE
 
$DD L%1.dir L%1.exp
 
  
 +
{{Code2|
 +
IND %1.phy %1.dak(I%2.dir) 2 1 ON
 +
$GRM L%2.dir L%1.exp U1
 +
IF %op(%2.dir,<nowiki>=</nowiki>,9535)
 +
$DISCON_ST L%1.dir 0
 +
IND %1.phy %1.dak(I%2.dir) 1 3 OFF
 +
PAUSE
 +
PAUSE
 +
PAUSE
 +
$DD L%1.dir L%1.exp
 +
}}
  
 +
'''Event 3: Reset LEDs when Dynamic Group Call ends'''
 +
*When the operator calls the dynamic group, stop the timer that resets all LEDs
 +
*When the call to the dynamic group call ends, reset all LEDs
  
DynGrp Event3.PNG
+
[[File:DynGrp Event3.PNG|thumb|left|500px|Reset LEDs]]
 +
<br style="clear:both;" />
  
IF %op(%2.dir,=,%1.exp)
+
{{Code2|
IF %chg(1,0)
+
IF %op(%2.dir,<nowiki>=</nowiki>,%1.exp)
$ST L%1.dir W0 L%1.exp
+
IF %chg(1,0)
stop
+
$ST L%1.dir W0 L%1.exp
ENDIF
+
stop
IND %1.phy 0 0 0 OFF
+
ENDIF
ENDIF
+
IND %1.phy 0 0 0 OFF
 +
ENDIF
 +
}}
  
  
DynGrp Event4.PNG
+
'''Event 4: Reset LEDs on timeout'''
 +
*If the operator exit the "Group Configuration" mode without starting the dynamic group call within set time, resets all LEDs
 +
 
 +
[[File:DynGrp Event4.PNG|thumb|left|500px|"Group Configuration" button]]
 +
<br style="clear:both;" />
  
IF %op(%2.dir,=,%1.exp)
+
{{Code2|
IND %1.phy 0 0 0 OFF
+
IF %op(%2.dir,<nowiki>=</nowiki>,%1.exp)
ENDIF
+
IND %1.phy 0 0 0 OFF
 +
ENDIF
 +
}}
  
[[Category: Applications]]
+
[[Category:AlphaCom Applications]]
 +
[[Category:ICX-AlphaCom Applications]]
 
[[Category: Control Room Applications]]
 
[[Category: Control Room Applications]]
 +
[[Category:Applications using Event Handler]]

Latest revision as of 11:13, 8 July 2022

AI.png

Operation

For best performance it is recommended to use CRM V station or ECPIR-3P panel, as these devices have buttons with LEDs showing status.

  • Press a dedicated "Group Configuration" DAK key. The red led in key starts flashing, and the Dynamic Group is emptied.
  • Select stations or local groups to be included by pressing the associated DAK keys. A steady green led in the keys indicates that the stations/groups are included
  • Press the "Group Configuration" button again, and the group call is activated (the ding-dong chime is played). Pressing the `M`-key opens the microphone.
  • The green leds continue to be lit during the group call
  • Cancel the group call by pressing the `C`-key. The green LEDs are turned off.
Note icon One can only include, not remove, stations/groups into the dynamic group. If a wrong selection is made, press the C-key, and start the selection over again.


Software requirements

  • ICX: Any version
  • AlphaCom: 13.0.3.0 or later

Configuration

  • Assign directory number 9535 to DAK 1 of the operator station. This is the Group Configuration button. Directory number 9535 is included in a default database.
"Group Configuration" button


  • Each operator station is assigned its own Dynamic Group Call by entering the directory number of the Dynamic Group Call in the User Defined Parameter (%1.EXP) field of the operator.
  • Include operator stations in UDP group 1. Name the UDP group e.g. "Operators".
Include the operator station in UDP Group 1, and enter the directory number of the Dynamic Group used by this operator (Here: 899)



Event Handler configuration

In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events (Simply copy/paste the action strings below into AlphaPro):

Event 1: Start/stop Group Configuration

  • When the "Group Configuration" button is pressed, empty the Dynamic Group and turn on red LED in the button.
  • When leaving the Group Configuration mode, start a 1 sec timer. If the Dynamic Group is not activated within this time, the LEDs will be cleared.
Start/stop Group Configuration


Action commands:

IF %chg(1,0)
$GRM LV L%1.exp U3
IND %1.phy %1.dak(I%2.dir) 1 3 ON
stop
ENDIF
$ST L%1.dir W10 L%1.exp


Event 2: Include members

  • When DAK keys are pressed during Group Configuration mode, turn on the green LED, and include the station or local group to the dynamic group
  • If the DAK key pressed is the "Group Configuration" button (9535), disconnect the station from configuration mode, turn off the red LED, and dispatch the dynamic group call
Include members


Action commands:

IND %1.phy %1.dak(I%2.dir) 2 1 ON 
$GRM L%2.dir L%1.exp U1
IF %op(%2.dir,=,9535)
$DISCON_ST L%1.dir 0
IND %1.phy %1.dak(I%2.dir) 1 3 OFF
PAUSE
PAUSE
PAUSE
$DD L%1.dir L%1.exp


Event 3: Reset LEDs when Dynamic Group Call ends

  • When the operator calls the dynamic group, stop the timer that resets all LEDs
  • When the call to the dynamic group call ends, reset all LEDs
Reset LEDs


Action commands:

IF %op(%2.dir,=,%1.exp)
IF %chg(1,0)
$ST L%1.dir W0 L%1.exp
stop
ENDIF
IND %1.phy 0 0 0 OFF
ENDIF



Event 4: Reset LEDs on timeout

  • If the operator exit the "Group Configuration" mode without starting the dynamic group call within set time, resets all LEDs
"Group Configuration" button


Action commands:

IF %op(%2.dir,=,%1.exp)
IND %1.phy 0 0 0 OFF
ENDIF