Actions

Difference between revisions of "ENA Amplifier - Report faults to Display Station"

From Zenitel Wiki

Line 10: Line 10:
  
 
[[File:Event ENA Errors.PNG|thumb|500px|left|Event 43 is used to report amplifer errors]]
 
[[File:Event ENA Errors.PNG|thumb|500px|left|Event 43 is used to report amplifer errors]]
 +
<br style="clear:both;" />
  
 
Action Command:
 
Action Command:

Revision as of 11:33, 12 April 2018

AlphaCom icon 300px.png

Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station.

Amplifier errors are reported by the Event Handler of the AlphaCom, event 43 - Station Fault Report. One can use the "subevent" to filter on specific fault types.

In order to have one common event for all ENA amplifiers, include the amplifiers in an UDP Group. Here UDP Group 3 is used as an example.

In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:

Event 43 is used to report amplifer errors


Action Command:

IF %chg(1,0)
$STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam'
STOP
ENDIF
$CANM %1.ref L164 NM253 U%op(70,+,%sev)