Revision as of 11:33, 12 April 2018
Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station.
Amplifier errors are reported by the Event Handler of the AlphaCom, event 43 - Station Fault Report. One can use the "subevent" to filter on specific fault types.
In order to have one common event for all ENA amplifiers, include the amplifiers in an UDP Group. Here UDP Group 3 is used as an example.
In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:
Action Command:
IF %chg(1,0) $STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam' STOP ENDIF $CANM %1.ref L164 NM253 U%op(70,+,%sev)