Actions

Difference between revisions of "ENA Amplifier - Report faults to Display Station"

From Zenitel Wiki

Line 18: Line 18:
  
 
<br><br>
 
<br><br>
The Event string will send a station-mail ([[$STM]]) to station 164 for all new fault codes. When a fault is reported "OFF" the mail message is automatically deleted. ([[$CANM]])
+
The event string will send a station-mail ([[$STM]]) to station 164 for all new fault codes. When a fault is reported "OFF" the mail message is automatically deleted. ([[$CANM]]). If you want the fault report to remain in the station also after the fault is gone, simply change "When Change To" = ON (not ON or OFF).
  
 
The priority of the mail will be the fault type + 70. The mail text will contain the directory number of the amplifier and the default fault text. Customized fault text can be used instead of the default text.
 
The priority of the mail will be the fault type + 70. The mail text will contain the directory number of the amplifier and the default fault text. Customized fault text can be used instead of the default text.
  
 
[[Category: Public Address]]
 
[[Category: Public Address]]

Revision as of 13:18, 12 April 2018

AlphaCom icon 300px.png
Amplifier faults, such as Speaker Line errors, can be reported to display stations

Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station. This is achieved by using event 43 - Station Fault Report, which is triggered whenever the ENA amplifier reports a fault.

In order to have one common event for all ENA amplifiers, include the amplifiers in an UDP Group. Here UDP Group 3 is used as an example.

In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:

Event 43 is used to report amplifer errors


Action Command:

IF %chg(1,0)
$STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam'
STOP
ENDIF
$CANM %1.ref L164 NM253 U%op(70,+,%sev)



The event string will send a station-mail ($STM) to station 164 for all new fault codes. When a fault is reported "OFF" the mail message is automatically deleted. ($CANM). If you want the fault report to remain in the station also after the fault is gone, simply change "When Change To" = ON (not ON or OFF).

The priority of the mail will be the fault type + 70. The mail text will contain the directory number of the amplifier and the default fault text. Customized fault text can be used instead of the default text.