Actions

Difference between revisions of "SET TIMER"

From Zenitel Wiki

 
(10 intermediate revisions by 8 users not shown)
Line 1: Line 1:
{| border="1" align=left
+
{{AI}}
 +
{| border="1"
 
|-
 
|-
 
!style="background:#ffdead;" width="90pt" colspan="2"|SET_TIMER
 
!style="background:#ffdead;" width="90pt" colspan="2"|SET_TIMER
 
!style="background:#ffdead;" width="100pt"|0x008F
 
!style="background:#ffdead;" width="100pt"|0x008F
 
!style="background:#ffdead;" width="30pt"|143
 
!style="background:#ffdead;" width="30pt"|143
!style="background:#ffdead;" width="100pt"|AMC 08.20
+
!style="background:#ffdead;" |AMC 08.20
 
|-
 
|-
|colspan="3"|$ST L102 W 50<br\>$ST  L102 <br\> $ST  L102 W 50 L(2)101 ‘my name’ U0<br\>$ST  L102 W 0 L(2)101
+
|colspan="3"|'''$ST L102 W50<br />$ST  L102''' <br /> '''$ST  L102 W50 L101 ‘my name’ U0'''<br />'''$ST  L102 W0 L101'''
|colspan="2" |''Set 5 second timer on station 102''<br\>''Stop all timers on station 102''<br\>''Set 5 sec, on station 102, from 101''<br\>''Stop timer  on station 102, from 101''
+
|colspan="2" |''Set 5 second timer on station 102''<br />''Stop all timers on station 102''<br />''Set 5 sec, on station 102, from 101''<br />''Stop timer  on station 102, from 101''
 
|-
 
|-
|colspan="5"|Start a timer or stop timer. When the timer expires, an [[EVENT_REPORT]] is generated, event type [[EVH_EVENT_TIMEOUT]] = 21. The timer can be stopped before expiry by setting a zero timeout value.  
+
|colspan="5"|Start a timer or stop timer. When the timer expires, an [[EVENT_REPORT]] is generated, event type [[Event Timeout (Event Type)|EVH_EVENT_TIMEOUT]] = 21. The timer can be stopped before expiry by setting a zero timeout value.  
 
A station must be specified as owner of the timer. It is also possible to specify the “related-to” parameters to be used in the timeout [[EVENT_REPORT]].  
 
A station must be specified as owner of the timer. It is also possible to specify the “related-to” parameters to be used in the timeout [[EVENT_REPORT]].  
 
A SET_TIMER will replace an existing running timer if both the owner station and related-to stations are identical. If none of the running timers are matching, a new independent timer is started. Omitting the related-to station has a special meaning for the stop operation: All timers with the specified owner station will be stopped.  
 
A SET_TIMER will replace an existing running timer if both the owner station and related-to stations are identical. If none of the running timers are matching, a new independent timer is started. Omitting the related-to station has a special meaning for the stop operation: All timers with the specified owner station will be stopped.  
Line 15: Line 16:
 
|align=center|1||[[NET_OBJ_REF]] {[[ECL_STATION]]}||colspan="3"|Station to receive timeout event (event owner). ([[NRF_LOCAL_DIRNO]] and [[NRF_LOCAL_ENTITY]] allowed.)
 
|align=center|1||[[NET_OBJ_REF]] {[[ECL_STATION]]}||colspan="3"|Station to receive timeout event (event owner). ([[NRF_LOCAL_DIRNO]] and [[NRF_LOCAL_ENTITY]] allowed.)
 
|-
 
|-
|align=center|2||[[UINT2]] <br\>(optional)||colspan="3"|Timeout value, measured in 100 ms ticks. Default value is zero, which means stop timer. Max value will give a 1 hour 49 minute timeout.
+
|align=center|2||[[UINT2]] <br />(optional)||colspan="3"|Timeout value, measured in 100 ms ticks. Default value is zero, which means stop timer. Max value will give a 1 hour 49 minute timeout.
 
|-
 
|-
|align=center|3||[[NET_OBJ_REF]]<br\> {[[ECL_STATION]]}<br\> (optional)
+
|align=center|3||[[NET_OBJ_REF]]<br /> {[[ECL_STATION]]}<br /> (optional)
 
|colspan="3"|Station to be used as related-to parameter in timeout event. Null value allowed.  (Only [[NRF_LOCAL_DIRNO]] allowed.)
 
|colspan="3"|Station to be used as related-to parameter in timeout event. Null value allowed.  (Only [[NRF_LOCAL_DIRNO]] allowed.)
 
|-
 
|-
|align=center|4||[[TEXT16]]<br\>(optional)||colspan="3"|Name of related-to parameter in timeout event (16 character). <br\>Default value:  Sending station’s name if specified.
+
|align=center|4||[[TEXT16]]<br />(optional)||colspan="3"|Name of related-to parameter in timeout event (16 character). <br />Default value:  Sending station’s name if specified.
 
|-
 
|-
|align=center|5||[[UINT1]]<br\>(optional)||colspan="3"|User Defined Properties ([[UDP]]) of related-to parameter in timeout event.  
+
|align=center|5||[[UINT1]]<br />(optional)||colspan="3"|User Defined Properties ([[UDP]]) of related-to parameter in timeout event.  
 
Default value: 0.  
 
Default value: 0.  
 
|-  
 
|-  
Line 28: Line 29:
 
|-
 
|-
 
|}
 
|}
 +
 +
[[Category: ACDP messages]]
 +
[[Category: DP Commands]]
 +
[[AlphaNet_Data_Protocol#General_Exchange_Control|Back to AlphaNet message list]]

Latest revision as of 13:10, 30 June 2022

AI.png
SET_TIMER 0x008F 143 AMC 08.20
$ST L102 W50
$ST L102

$ST L102 W50 L101 ‘my name’ U0
$ST L102 W0 L101
Set 5 second timer on station 102
Stop all timers on station 102
Set 5 sec, on station 102, from 101
Stop timer on station 102, from 101
Start a timer or stop timer. When the timer expires, an EVENT_REPORT is generated, event type EVH_EVENT_TIMEOUT = 21. The timer can be stopped before expiry by setting a zero timeout value.

A station must be specified as owner of the timer. It is also possible to specify the “related-to” parameters to be used in the timeout EVENT_REPORT. A SET_TIMER will replace an existing running timer if both the owner station and related-to stations are identical. If none of the running timers are matching, a new independent timer is started. Omitting the related-to station has a special meaning for the stop operation: All timers with the specified owner station will be stopped.

1 NET_OBJ_REF {ECL_STATION} Station to receive timeout event (event owner). (NRF_LOCAL_DIRNO and NRF_LOCAL_ENTITY allowed.)
2 UINT2
(optional)
Timeout value, measured in 100 ms ticks. Default value is zero, which means stop timer. Max value will give a 1 hour 49 minute timeout.
3 NET_OBJ_REF
{ECL_STATION}
(optional)
Station to be used as related-to parameter in timeout event. Null value allowed. (Only NRF_LOCAL_DIRNO allowed.)
4 TEXT16
(optional)
Name of related-to parameter in timeout event (16 character).
Default value: Sending station’s name if specified.
5 UINT1
(optional)
User Defined Properties (UDP) of related-to parameter in timeout event.

Default value: 0.

Response: None

Back to AlphaNet message list