Revision as of 11:42, 12 April 2018
Event description
Event Owner: | Station reporting the fault. |
Event type: | 43 - Station Fault Report |
Subevent: | Fault type, see list below |
When change to ON: | When fault is active. |
When change to OFF: | When fault is gone |
When related to: | Fault description text returned in %2.nam |
If Subevent is set to 255, all fault types will be reported. One can use %sev to read the subevent number.
Fault types
0. Any amplifier fault
1. Any fault, Channel 1
2. Any fault, Channel 2
3. LET fault, Channel 1
4. LET fault, Channel 2
5. Amplifier shutdown, Channel 1
6. Amplifier shutdown, Channel 2
7. SLM faults, Channel 1
8. SLM faults, Channel 2
9. Over temperature, Channel 1
10. Over temperature, Channel 2
11. Cooling fan fault
12. Eth1 fault
13. Eth2 fault
14. Software fault
15. AC power fault
16. DC power fault
17. EMBDR-8 missing
18. MIC fault
19. RCO Fault
20. RCI Fault
Applications