(Single TFIX with beacon)
(Multiple TFIX'es with beacon)
Line 27: Line 27:
 
* 1 IP Station License
 
* 1 IP Station License
 
* 1 Turbine Relay board; TA-10
 
* 1 Turbine Relay board; TA-10
* 1 Power supply; 24VDC or 230VAC
+
* 1 Beacon PSU; 24VDC or 230VAC
 
* 1 Flowire unit; FCDC
 
* 1 Flowire unit; FCDC
* 1 24VDC PSU for the Flowire
+
* 1 24VDC Flowire PSU
  
 
[[File:TFIX Beacon Multiple2.png|thumb|left|500px]]
 
[[File:TFIX Beacon Multiple2.png|thumb|left|500px]]
Line 43: Line 43:
 
* 1 24VDC PSU: for the MRBD
 
* 1 24VDC PSU: for the MRBD
 
* 1 Flowire unit; FCDC
 
* 1 Flowire unit; FCDC
* 1 24VDC PSU for the Flowire
+
* 1 24VDC Flowire PSU
 
* 6 Relay boxes; [[IRR-3 Relay unit|IRR-3]]
 
* 6 Relay boxes; [[IRR-3 Relay unit|IRR-3]]
 
* 6 Beacons; BEX24O or BEX230O
 
* 6 Beacons; BEX24O or BEX230O
* 6 Powers supplies; 24VDC or 230VAC
+
* 6 Beacon Powers supplies; 24VDC or 230VAC
  
 
[[File:TFIX Beacon Multiple1.png|thumb|left|500px]]
 
[[File:TFIX Beacon Multiple1.png|thumb|left|500px]]

Revision as of 13:18, 2 October 2015

ARTICLE UNDER CONSTRUCTION!!!

TFIX station with beacon

A beacon lamp can be used to indicate an incoming call or PA announcement.

Single TFIX with beacon

A single TFIX with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 IP Station License
  • 1 Turbine Relay board; TA-10
  • 1 Beacon PSU; 24VDC or 230VAC
  • 1 Flowire unit; FCDC
  • 1 24VDC Flowire PSU
TFIX Beacon Single.png


Detailed connection diagram


Multiple TFIX'es with beacon

Multiple TFIX'es with beacon in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 IP Station License
  • 1 Turbine Relay board; TA-10
  • 1 Beacon PSU; 24VDC or 230VAC
  • 1 Flowire unit; FCDC
  • 1 24VDC Flowire PSU
TFIX Beacon Multiple2.png



Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:

  • 1 Turbine compact Kit; TKIS-2
  • 1 IP Station License
  • 1 Multi-relay board; MRBD
  • 1 24VDC PSU: for the MRBD
  • 1 Flowire unit; FCDC
  • 1 24VDC Flowire PSU
  • 6 Relay boxes; IRR-3
  • 6 Beacons; BEX24O or BEX230O
  • 6 Beacon Powers supplies; 24VDC or 230VAC
TFIX Beacon Multiple1.png


Detailed connection diagram