Actions

Difference between revisions of "TFIX - Installation Solutions"

From Zenitel Wiki

(Single TFIX with beacon)
(Related articles)
 
(13 intermediate revisions by 2 users not shown)
Line 1: Line 1:
'''ARTICLE UNDER CONSTRUCTION!!!'''
+
== TFIX station with external signal device ==
  
== TFIX station with beacon ==
+
In noisy areas a beacon lamp and/or a signal bell/horn can be used to indicate an incoming call or PA announcement.
  
A beacon lamp can be used to indicate an incoming call or PA announcement.
+
== Single TFIX with external signal device ==
 
+
A single TFIX with external signal device in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field. <br/>
== Single TFIX with beacon ==
 
A single TFIX with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field. <br/>
 
 
The cabinet consist of:
 
The cabinet consist of:
 
* 1 Turbine extended kit; TKIE
 
* 1 Turbine extended kit; TKIE
* 1 IP Station License
 
 
* 1 Turbine Relay board; TA-10
 
* 1 Turbine Relay board; TA-10
* 1 Power supply; 24VDC or 230VAC
+
* 1 24VDC or 230VAC PSU for signal device
* 1 Flowire unit; FCDC
+
* 1 Flowire unit; FCDC2
 
* 1 24VDC Flowire PSU
 
* 1 24VDC Flowire PSU
* 1 Beacon PSU; 24VDC or 230VAC
 
  
 
[[File:TFIX Beacon Single.png|thumb|left|500px]]
 
[[File:TFIX Beacon Single.png|thumb|left|500px]]
Line 22: Line 18:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
== Multiple TFIX'es with beacon ==
+
== Multiple TFIX'es with external signal device ==
Multiple TFIX'es with beacon in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field. <br/>
+
Multiple TFIX'es with external signal device in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field. <br/>
 
Each cabinet consist of:
 
Each cabinet consist of:
 
* 1 Turbine extended kit; TKIE
 
* 1 Turbine extended kit; TKIE
* 1 IP Station License
 
 
* 1 Turbine Relay board; TA-10
 
* 1 Turbine Relay board; TA-10
* 1 Power supply; 24VDC or 230VAC
+
* 1 24VDC or 230VAC PSU for external signal device
* 1 Flowire unit; FCDC
+
* 1 Flowire unit; FCDC2
* 1 24VDC PSU for the Flowire
+
* 1 24VDC Flowire PSU
  
 
[[File:TFIX Beacon Multiple2.png|thumb|left|500px]]
 
[[File:TFIX Beacon Multiple2.png|thumb|left|500px]]
Line 37: Line 32:
 
----
 
----
  
Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room. <br/>
+
Multiple TFIX'es with external signal device in the EX zone, where all controlling equipment is located in the server room. <br/>
 
For every sixth TFIX with beacon you need:
 
For every sixth TFIX with beacon you need:
* 1 Turbine compact Kit; [[TKIS-2 VoIP Intercom Module - 1008131020|TKIS-2]]
+
* 1 Turbine compact Kit; [[TKIS-2]]
* 1 IP Station License
 
 
* 1 Multi-relay board; [[MRBD]]
 
* 1 Multi-relay board; [[MRBD]]
 
* 1 24VDC PSU: for the MRBD
 
* 1 24VDC PSU: for the MRBD
* 1 Flowire unit; FCDC
+
* 1 Flowire unit; FCDC2
* 1 24VDC PSU for the Flowire
+
* 1 24VDC Flowire PSU
 
* 6 Relay boxes; [[IRR-3 Relay unit|IRR-3]]
 
* 6 Relay boxes; [[IRR-3 Relay unit|IRR-3]]
* 6 Beacons; BEX24O or BEX230O
+
* 6 External signal devices; Beacon BEX24O/BEX230O, or Signal bell/horn DHW2-24/DHH1-230
* 6 Powers supplies; 24VDC or 230VAC
+
* 6 24VDC or 230VAC PSU for external signal device
  
 
[[File:TFIX Beacon Multiple1.png|thumb|left|500px]]
 
[[File:TFIX Beacon Multiple1.png|thumb|left|500px]]
Line 55: Line 49:
  
 
== Related articles ==
 
== Related articles ==
* [[Turbine Compact and MRBD]]
+
*[[Adding additional relay(s) to a Zenitel IP Device]]
 
* [[IRR-3 Relay unit]]
 
* [[IRR-3 Relay unit]]

Latest revision as of 16:19, 23 June 2023

TFIX station with external signal device

In noisy areas a beacon lamp and/or a signal bell/horn can be used to indicate an incoming call or PA announcement.

Single TFIX with external signal device

A single TFIX with external signal device in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 Turbine Relay board; TA-10
  • 1 24VDC or 230VAC PSU for signal device
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
TFIX Beacon Single.png


Detailed connection diagram


Multiple TFIX'es with external signal device

Multiple TFIX'es with external signal device in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 Turbine Relay board; TA-10
  • 1 24VDC or 230VAC PSU for external signal device
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
TFIX Beacon Multiple2.png



Multiple TFIX'es with external signal device in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:

  • 1 Turbine compact Kit; TKIS-2
  • 1 Multi-relay board; MRBD
  • 1 24VDC PSU: for the MRBD
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
  • 6 Relay boxes; IRR-3
  • 6 External signal devices; Beacon BEX24O/BEX230O, or Signal bell/horn DHW2-24/DHH1-230
  • 6 24VDC or 230VAC PSU for external signal device
TFIX Beacon Multiple1.png


Detailed connection diagram


Related articles