Actions

Difference between revisions of "Turbine Software Upgrade"

From Zenitel Wiki

(Upgrade procedure)
(Devices with Recovery OS)
 
(261 intermediate revisions by 6 users not shown)
Line 1: Line 1:
This article describes how to upgrade the software of the Turbine series of intercom devices from version 3.0.x.x to version 4.2.3.0.
+
{{AEIPS}}
 +
This article describes how to upgrade the software of the [[:Category:Stations#Turbine_stations|Turbine series of intercom devices]] via the '''web interface''' of the station.  
  
There are two ways of upgrading the software on the Turbine station:  
+
{{Note|
* Using the VS-IMT Intercom Management Tool
+
* ''The procedure described in this article is applicable to the following devices: '''TCIS-x''', '''TCIV-x''', '''TKIS-2''', '''TMIS-x''', '''TFIE-x''', '''TKIE-x''', '''TFIX-x''', '''IP-LCM''', '''ECPIR-3P''', '''Exigo IP speakers'''. '''Exigo Network Amplifiers''', and '''ENA-2060DC1'''''
* Using the web interface of the station it self
+
* ''For mass upgrade of stations it is recommended to use the [[IMT|VS-IMT]] tool, see the article [[IMT - Discover & Upgrade]].''
 +
* ''Using Turbine version 4.7.3.2 or higher, you can downgrade to VSF-Turbine version 4.2.3.17, but not to any older version.''
 +
* ''There is a separate Upgrade procedure for [[INCA Station Software upgrade|INCA IP stations.]]''
 +
* ''If the station is used in SIP mode, also [[Automatic Software Upgrade|Automatic Updates]] can be defined.'' }}
 +
<div style="float:right;"> <youtube width="300" height="180">WS-ysJCOYcI</youtube> </div>
  
The VS-IMT tool allows mass upgrade of stations.
+
There are two ways of updating the software of these devices from the web interface:
 +
* By using an [[#Upgrade by using an external TFTP server|external TFTP server]], or
 +
* By uploading an image file (or drag and drop the image file) to the "Software Upgrade" page of the station. '''Note:''' This option is available only to [[#Devices with Recovery OS|stations with Recovery OS]].
  
* ....
+
== Upgrade using the IMT-tool==
* ....
+
Upgrade of station can be done from the Windows PC tool [[IMT|VS-IMT]], see the article [[IMT - Discover & Upgrade]].
  
==Using the Web Interface of the station ==
+
<br>
  
 +
== Upgrade by using an external TFTP server ==
 
===Prerequisites===
 
===Prerequisites===
# A TFTP Server must be available. A TFTP server can be downloaded from here: http://tftpd32.jounin.net/tftpd32_download.html.
+
# Current version '''must be 4.7.3.2 or higher'''. To upgrade from older versions, [[Upgrading Turbine Devices running firmware between 3.0.x.x and 4.2.x.x|see this article]].
# Download the software package '''tsi-3.0.3.5.zip''', and unzip the files to a folder on your PC.
+
# A TFTP Server must be available on your laptop. A TFTP server can be downloaded from here: http://tftpd32.jounin.net/tftpd32_download.html.
# Download the software package '''sti-prod-4.2.3.0.zip''', and unzip the files to a different folder on your PC.
+
# Download the software package '''[[Downloads#Stations_and_Devices|vsft-8.x.x.x.zip]]''', and '''unzip the package''' and store the files in a folder on your PC.
 +
# Check if your local firewall is '''not''' blocking incoming ping/ICMP  (Turbine station is pinging TFTP Server during update process)
 +
<br>
  
 
=== Upgrade procedure ===
 
=== Upgrade procedure ===
The upgrade is a two-step process:
+
# Start the TFTP server program and click '''Browse''', and select the folder where the 8.x.x.x software files are located
* First install version 3.0.3.5, then
+
# [[Logging into an IP Station|Log on to the Turbine Station]] web interface. Select '''Station Administration''' > '''Manual Upgrade'''
* Install version 4.2.3.0
+
# Enter the IP address of the '''TFTP server''' (I.e. the IP address of your laptop)
 +
# Enter Image file: '''vsft-8.x.x.x'''
 +
# '''Save Settings'''
 +
# '''Upgrade'''
  
1. Start the TFTP server program and click '''Browse''', and select the folder where the version 3.0.3.5 software files are located
+
[[File:Upgrade to 7.1.3.0.PNG|thumb|left|700px|Example: Upgrade to the latest the firmware from TFTP Server 10.9.9.217]]
 +
<br style="clear:both;" />
  
[[File:TFTP 3035.PNG|thumb|left|500px|TFTP Server - Browse to the folder where the software files are located]]
 
<br style="clear:both;" />
 
  
2.  Log on to the Turbine Station web interface. Default login credentials are '''admin''' and '''alphaadmin'''. Select '''Station Administration''' > '''Manual Upgrade'''
+
The device will restart with the new firmware installed.  
  
3. Enter the IP address of the '''TFTP server''' (I.e. the IP address of your PC)
+
The upgrade procedure takes about 3 minutes. The process can be monitored by clicking the '''Log viewer''' tab in the TFTP server program.
  
4.  Enter the image file: '''tsi-3.0.3.5''', and click '''Save settings'''
+
<br>
  
[[File:TurbineTo 3035.PNG|thumb|left|500px|Load '''tsi-3.0.3.5''' via the station web interface]]
+
== Devices with Recovery OS ==
<br style="clear:both;" />
+
As from firmware version 5.1.3.0 a Recovery Operating System, '''Recovery OS''', has been added in addition to the Main OS.
  
The station will now contact the TFTP server and download the files. The upgrade procedure takes about 3 minutes. The process can be monitored by clicking the '''Log viewer''' tab in the TFTP server program.
+
{{note|
 +
* ''"Recovery OS" is available only on Turbine devices that '''come from factory''' with software version 5.1 or higher preinstalled (approx. from March 2020)'' <br>
 +
* ''When upgrading to firmware 5.1. or later in the field, "Recovery OS" will not be included'' }}
  
 +
The Recovery OS supports:
 +
* Software upgrade in IPv6 network
 +
* Software upgrade when device is using [[IEEE 802.1X|802.1X authentication]]
 +
* Software upgrade via HTTP/HTTPS protocol using '''.swu''' image
  
When the station is up and running again, the next step is to install version 4.2.3.0:
+
Devices with Recovery OS support both the new method for software upgrade (using '''.swu''' file), as well as the original method (using '''.zip''' file and TFTP server).
  
5. In the TFTP server program, '''Browse''' to the folder where the version 4.2.3.0 software files are located
+
[[File:Turbine Upgr Both.PNG|thumb|left|500px|Choose between upgrading using '''.swu''' file, or using TFTP server and '''.zip''' file]]
 +
<br style="clear:both;" />
  
6. In the Turbine web interface enter the image file: '''tsi2sti-4.2.3.0.ipk''', and '''Save settings'''
+
In order to upgrade software using the .swu file:
 +
* Press the ''upper'' '''Start Upgrade''' button
 +
* The station will now reboot, and start in "Recovery OS" mode
  
[[File:TurbineTo 4230.PNG|thumb|left|500px|Installing '''tsi2sti-4.2.3.0.ipk''' via the station web interface]]
+
[[File:Turbine Recovery.PNG|thumb|left|500px|Turbine device in "Recovery OS" mode]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
The station will again contact the TFTP server and download and install the required files.
+
* Now click inside the "Software Update" field and upload the image file (e.g. '''vsft-8.0.3.2.swu'''), or drag and drop the image file onto this field
 +
* The progress of the installation is shown. When finished installation the station will reboot, and start in regular mode.
  
===Troubleshooting===
+
<br>
In the case the upgrade is not successful it may be due to a windows setting.
 
  
For Windows XP: [http://www.sysprobs.com/enable-ping-in-xp http://www.sysprobs.com/enable-ping-in-xp]
+
==Upgrade from versions between 3.0 and 4.2==
 +
To upgrade devices currently running a version between 3.0.x.x and 4.2.x.x, see article: [[Upgrading Turbine Devices running firmware between 3.0.x.x and 4.2.x.x]]
  
For Windows7: [http://www.sysprobs.com/enable-ping-reply-windows-7 http://www.sysprobs.com/enable-ping-reply-windows-7]
+
<br>
  
 +
== Upgrade in 802.1x environment ==
 +
Devices with Recovery OS can be upgraded also when the station uses 801.1x authentication. For more details, see [[IEEE 802.1X]]
  
==Using the IMT tool ==
+
<br>
  
===Prerequisites===
+
==Troubleshooting==
# Download and install the VS-IMT tool
+
In the case the upgrade is not successful it may be due to a windows setting.  
# Download the software package '''tsi-3.0.3.5.zip'''. Unzip the package and store the files in the folder  '''sw_repo''' under '''My Documents''' > '''Intercom Manager Tool'''.
 
# Download the software package '''sti-prod-4.2.3.0.zip'''. Unzip the package and store the files in the folder  '''sw_repo''' under '''My Documents''' > '''Intercom Manager Tool'''.
 
  
[[File:IMT SWrepo.PNG|thumb|left|500px|The software packages must be stored under My Documents > Intercom Manager Tool > sw_repo]]
+
*For Windows XP: [http://www.sysprobs.com/enable-ping-in-xp http://www.sysprobs.com/enable-ping-in-xp]
<br style="clear:both;" />
 
  
=== Upgrade procedure ===
+
*For Windows7: [http://www.sysprobs.com/enable-ping-reply-windows-7 http://www.sysprobs.com/enable-ping-reply-windows-7]
  
* Start the IMT tool
+
*For Windows10: [http://www.sysprobs.com/enable-ping-reply-and-ftp-traffic-in-windows-10-and-server http://www.sysprobs.com/enable-ping-reply-and-ftp-traffic-in-windows-10-and-server]
* Select '''Create project''', and start the wizard that takes you through the discovery and upgrade process, by selecting '''File''' > '''Launch Station Wizard'''
 
* Press '''Next''' to go to Station Discovery. Enter the range of IP addresses (From - To) to search for, and press '''Search'''
 
* When the discovery process is finished, select all stations in the list by checking the '''Select All''' flag
 
 
 
[[File:IMT SelectAll.PNG|thumb|left|500px|Bla bla bla]]
 
<br style="clear:both;" />
 
* Press '''Next''' two times. Now you come to the "Upgrade Stations" window.
 
  
 +
If the upgrade is not successful when using the default static IP, it may be due to a network setting.
 +
* Please check the station's subnet mask. If it is 255.255.0.0, change it to 255.255.255.0 and try again
  
[[Category:Turbine]]
+
[[Category: Turbine - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 11:11, 4 December 2023

AEIPS.png

This article describes how to upgrade the software of the Turbine series of intercom devices via the web interface of the station.

Note icon
  • The procedure described in this article is applicable to the following devices: TCIS-x, TCIV-x, TKIS-2, TMIS-x, TFIE-x, TKIE-x, TFIX-x, IP-LCM, ECPIR-3P, Exigo IP speakers. Exigo Network Amplifiers, and ENA-2060DC1
  • For mass upgrade of stations it is recommended to use the VS-IMT tool, see the article IMT - Discover & Upgrade.
  • Using Turbine version 4.7.3.2 or higher, you can downgrade to VSF-Turbine version 4.2.3.17, but not to any older version.
  • There is a separate Upgrade procedure for INCA IP stations.
  • If the station is used in SIP mode, also Automatic Updates can be defined.


There are two ways of updating the software of these devices from the web interface:

Upgrade using the IMT-tool

Upgrade of station can be done from the Windows PC tool VS-IMT, see the article IMT - Discover & Upgrade.


Upgrade by using an external TFTP server

Prerequisites

  1. Current version must be 4.7.3.2 or higher. To upgrade from older versions, see this article.
  2. A TFTP Server must be available on your laptop. A TFTP server can be downloaded from here: http://tftpd32.jounin.net/tftpd32_download.html.
  3. Download the software package vsft-8.x.x.x.zip, and unzip the package and store the files in a folder on your PC.
  4. Check if your local firewall is not blocking incoming ping/ICMP (Turbine station is pinging TFTP Server during update process)


Upgrade procedure

  1. Start the TFTP server program and click Browse, and select the folder where the 8.x.x.x software files are located
  2. Log on to the Turbine Station web interface. Select Station Administration > Manual Upgrade
  3. Enter the IP address of the TFTP server (I.e. the IP address of your laptop)
  4. Enter Image file: vsft-8.x.x.x
  5. Save Settings
  6. Upgrade
Example: Upgrade to the latest the firmware from TFTP Server 10.9.9.217



The device will restart with the new firmware installed.

The upgrade procedure takes about 3 minutes. The process can be monitored by clicking the Log viewer tab in the TFTP server program.


Devices with Recovery OS

As from firmware version 5.1.3.0 a Recovery Operating System, Recovery OS, has been added in addition to the Main OS.

Note icon
  • "Recovery OS" is available only on Turbine devices that come from factory with software version 5.1 or higher preinstalled (approx. from March 2020)
  • When upgrading to firmware 5.1. or later in the field, "Recovery OS" will not be included


The Recovery OS supports:

  • Software upgrade in IPv6 network
  • Software upgrade when device is using 802.1X authentication
  • Software upgrade via HTTP/HTTPS protocol using .swu image

Devices with Recovery OS support both the new method for software upgrade (using .swu file), as well as the original method (using .zip file and TFTP server).

Choose between upgrading using .swu file, or using TFTP server and .zip file


In order to upgrade software using the .swu file:

  • Press the upper Start Upgrade button
  • The station will now reboot, and start in "Recovery OS" mode
Turbine device in "Recovery OS" mode


  • Now click inside the "Software Update" field and upload the image file (e.g. vsft-8.0.3.2.swu), or drag and drop the image file onto this field
  • The progress of the installation is shown. When finished installation the station will reboot, and start in regular mode.


Upgrade from versions between 3.0 and 4.2

To upgrade devices currently running a version between 3.0.x.x and 4.2.x.x, see article: Upgrading Turbine Devices running firmware between 3.0.x.x and 4.2.x.x


Upgrade in 802.1x environment

Devices with Recovery OS can be upgraded also when the station uses 801.1x authentication. For more details, see IEEE 802.1X


Troubleshooting

In the case the upgrade is not successful it may be due to a windows setting.

If the upgrade is not successful when using the default static IP, it may be due to a network setting.

  • Please check the station's subnet mask. If it is 255.255.0.0, change it to 255.255.255.0 and try again