This article describes how to upgrade from a Pulse system to an IC-EDGE System.

Firmware versions

Pulse System:

  • In a Pulse system the Turbine devices are running firmware 3.x or 4.x.
  • In a Pulse system the INCA devices are running firmware 2.9 or earlier.

IC-EDGE System:

  • In an IC-EDGE system all Turbine devices are running firmware 5.x.
  • In an IC-EDGE system all INCA devices are running firmware 2.10 or newer.

Prerequisites

  • All devices in the system must be upgraded to firmware 5.x (Turbine) and 2.10 (INCA)
  • In an IC-EDGE System, INCA stations cannot be used as the Edge Controller.
  • TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices.
  • VS-IMT can be used for station discovery and upgrade, but should not be used to configure Edge.

Licenses

Pulse licenses will be honored in an IC-EGDE System. This means that when upgrading a Pulse Server to version 5.x, licenses will still be valid.
More information regarding licensing in Edge can be found here.

Select Edge Controller

The Edge Controller must be a Turbine device. If the current Pulse Server is an Inca station, you must select a different device (Turbine) as the Edge Controller.

Upgrade the Stations

In an IC-EDGE System all station must be upgraded to Edge. You cannot mix Edge and Pulse devices.
Make sure all Turbine station runs 5.0.3.0 or newer.
Inca stations must run 02.10.3.0 or newer.
Software can be found here.

Upgrade procedure using VS-IMT can be found here.
Manual upgrade procedure can be found here.

Edge Configuration

Detailed information on how to configure Edge can be found here.