Actions

Difference between revisions of "VSF-Fortitude8 8.1 Release Notes"

From Zenitel Wiki

(VSF-FORTITUDE8 8.0.3.0)
(Improvements)
Line 21: Line 21:
  
 
==Improvements==
 
==Improvements==
=== MTN-2448 Support for uploading HTTPS certificates===  
+
===MTN-4156 Added option for using Normally Closed switch on I/O Pins configured as input===
A more user friendly approach to allow end-user to generate the CSR, and to upload HTTPS certificate to the devices.
+
The default input configuration is Normally Open and the switch contact needs to close to activate the function. A new option “Input NC” has been added to the I/O Pin configuration, which inverts the default behavior and the function is activated on switch open.
 
 
=== DS-592 OpenSSL upgraded to 3.0===
 
OpenSSL has been upgraded to the latest LTS version.
 
  
 
<br>
 
<br>

Revision as of 14:20, 6 February 2024

This document provides the release notes for VSF-Fortitude8 8.1 with incremental bug fix releases. The release notes for VSF-Fortitude8 8.0 describe new features, improvements and issues fixed after VSF-Fortitude8 8.0.3.2.

Release info

Name: VSF-Fortitude8
Description: VSF-Fortitude8 is a firmware for Turbine Plus Intercoms including the following devices: TCIV-2+, TCIV-3+, TCIV-5+, TCIV-6+, TKIV+, TMIV-1+, TEIV-1+ and TEIV-4+.

The firmware is delivered in two different files:

  • vsff8-8.1.3.x - Used for standard in-field upgrades
  • vsff8-prod-8.1.3.x - Used in production- and recovery upgrades.

Version: 8.1.3.0
Date: 02.02.2024
Status: General Availability

VSF-FORTITUDE8 8.1.3.0

Improvements

MTN-4156 Added option for using Normally Closed switch on I/O Pins configured as input

The default input configuration is Normally Open and the switch contact needs to close to activate the function. A new option “Input NC” has been added to the I/O Pin configuration, which inverts the default behavior and the function is activated on switch open.


Issues fixed

MTN-4229 HD audio for back ground music distribution in ICX-AlphaCom produced noise

Issue with PCM sampling is now fixed.

MTN-4206 SIP H.264 video calls are now working properly with Genetec Sipelia and Cisco

There was an issue with SIP H.264 video calls with Genetec Sipelia and Cisco, this is now fixed.

MTN-4181 Report DAK and Report station call events as Digital Input in ONVIF options are now working for Hanwha VMS

There was an issue with how Report DAK and Report station call events as Digital Input in ONVIF options were behaving in Hanwha VMS, this is now fixed and they work as expected.

MTN-4176 AVC config now shown under Audio Settings

AVC config was missing on 7.5 version. This is fixed, AVC is now visible and configurable.

MTN-4072 JQuery version update to version 3.6.4

Now the Station Web is running newer JQuery version with included JQuery migrate to support some of the older functions.


Known Issues

MTN-4121 Known issue: Asterisk discards alternative profiles

Default setting for ITSV-5 sends 3 types (BP & MP & HP). However, Asterisk discards all but the first profile it receives (HP in this case). Since only the "Baseline profile" is supported on the device the video doesn't load. A workaround to this issue is to select "Baseline profile" as the H.264 profile type on the ITSV-5.

The issue has been reported and documented here: https://issues.asterisk.org/jira/browse/ASTERISK-29182