PA Failure State System
From Zenitel Wiki
Contents
PA Failure State System
When used as PA interface some of the IP-ARIO inputs are used for reporting failure state of 1 or 2 amplifiers.
The various IP-ARIO PA faults and states are reported as sub events on the 13-Faulty Station Line.
When a fault state is reported OFF from IP-ARIO, the fault state in AlphaCom will stay active until acknowledged and cleared by the user.
Subevent 10-18 will only be reported once. The error will stay active in the system, even if the error has been removed, until one have performed an ACK/CLEAR sequence.
A NVRAM structure is used for additional configurable elements.
Configurable elements are:
- Default description text intended for use in fault mail to PA panels. The text are sent to event handler as %2.nam
- Default placement of status indication in the "DAK block" related to the PA interface. ( DAK block)
- Default priority used for fault mails. (Unique priority make it easy to remove specific fault from mail queues)
Event Handler IP-ARIO failure states | ||||||
---|---|---|---|---|---|---|
Event text (%2.nam) | SUB event (%sev) | DAK block index (%pai) | Priority (%pap) | Comment | ||
FAULT ACK | 2 | 7 | 50 | Event text for debugging | ||
FAULT CLEAR | 3 | 10 | 50 | Event text for debugging | ||
ZONE BLINK | 4 | 1 | 50 | Event text for debugging | ||
ZONE STEADY | 5 | 1 | 50 | Event text for debugging | ||
IPA DOWN | 10 | 4 | 140 | |||
RELAY 1 | 11 | 2 | 100 | |||
POWER 1 | 12 | 5 | 101 | |||
LINE MON 1 | 13 | 8 | 102 | |||
XLR MON 1 | 14 | 11 | 103 | |||
RELAY 2 | 15 | 3 | 104 | |||
POWER 2 | 16 | 6 | 105 | |||
LINE MON 2 | 17 | 9 | 106 | |||
XLR MON 2 | 18 | 12 | 107 | |||
- | 20 | - | - | "Live" State of Line Mon. 1 | ||
- | 21 | - | - | "Live" State of Line Mon. 2 | ||
- | 22 | - | - | "Live" State of Amp 1 Discon. | ||
- | 23 | - | - | "Live" State of Amp 2 Discon. | ||
- | 24 | - | - | "Live" State of 20KHZ Mon. 1 | ||
- | 25 | - | - | "Live" State of 20KHZ Mon. 2 | ||
- | 26 | - | - | "Live" State of Level Detect. 1 | ||
- | 27 | - | - | "Live" State of Level Detect. 2 |
Updated Event Handler Macros and $DP messages
wudd (Added label and string variables) %udd (Added label and string variables) gind (NEW group version of ind) %paf (NEW, PA fault in UDP group check) %pai (NEW, PA fault indicator in DAK block) %pap (NEW, PA fault mail priority) %prci (NEW, Current Physical RCI state) %prco (NEW, Current Physical RCO state)
$PA_CMD (NEW, PA command, ACK/CLEAR) $SET_IPRCO (NEW, Set physical RCO on IP station/IP-ARIO) $CANCEL_MAIL(Added option for delete mail with specific priority, Mail-id = 253)
Default Grouping of fault state on CRM DAK
The status of faults of one IP-ARIO are grouped to one CRM DAK block of 3 * 4 DAK keys.
Fault Indication On DAK panel | ||||||
---|---|---|---|---|---|---|
ZONE FAULT | RELAY 1 | RELAY 2 | ||||
IPA DOWN | POWER 1 | POWER 2 | ||||
FAULT ACK | LINE MON 1 | LINE MON 2 | ||||
FAULT CLEAR | XLR DISCON 1 | XLR DISCON 2 |
PA fault Example Configuration
Fault Handeling on a CRM with DAK pannels
The status of faults of one IP-ARIO are grouped to one CRM DAK block of 3 * 4 DAK keys.
DAK block
The block number used for each IP-ARIO is configured in AlphaPro->Station-> "used defined parameter" (%EXP).
Block number 1 to 8.
Example system:
- Three IP-ARIO in UDP group 1, DAK block 1,2 and 3 programmed in EXP.
- Two CRM with DAK modules in station group 2 and UDP 2.
- RCO 1 used for fault indication of fault state in UDP group 1 (ON or OFF)
Event for fault indication and fault mail
The following event will do: (in this order)
- Set fault indicators on CRM DAK panels in CRM group 2 in the DAK block position.
- Send Mail and Cancel Mail to CRM group 2, with related fault priority.
- Set Zone fault indicator on CRM DAK blinking/steady/off
- Set fault indicator led on IP-ARIO
- Set global fault indicator (RCO) related to fault in UDP group 1 (Do we need blinking?)
- Control ACK and CLEAR status led for the related DAK Block leds.
Owner: UDP 1 Event Type 13-Faulty station line Sub Event 255 When Change ON/OFF Action: if %op(%sev,>=,10) gind 2 %pai(%1.exp) 1 1 if %chg(1,0) $STM %1.ref L85 U%pap '(%1.dir) %2.nam' stop endif $CANM %1.ref L85 NM253 U%pap stop endif $SLRC W1 U%paf(1) if %op(%sev,=,4) gind 2 %pai(%1.exp) 1 2 ind %1.phy 1 1 2 stop endif gind 2 %pai(%1.exp) 1 1
Fault ACK/CLEAR on DAK keys
- One common ACK event for all CRM stations in UDP 2 for each IP-ARIO.
Owner: UDP 2 Event Type 30-DAK AS RCI Sub Event CRM DAK key used for Ack When Change ON Action: $PA_CMD L(IP-ARIO) U01
- One common Clear event for all CRM stations in UDP 2 for each IP-ARIO.
Owner: UDP 2 Event Type 30-DAK AS RCI Sub Event CRM DAK key used for Clear When Change ON Action: $PA_CMD L(IP-ARIO) U02