Actions

Turbine 6.2 - Release notes

From Zenitel Wiki

Previous Release - Turbine 6.1 - Release notes

Next Release - Turbine 6.4 - Release notes

This document provides the release notes for VSF-Turbine 6.2 with incremental bug fix releases. The release notes for VSF-Turbine 6.2 describe new features, improvements and issues fixed after VSF-Turbine 6.1.

Contents

Release info

Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices: TCIS-x, TCIV-x, TKIS-2, TMIS-x, TFIE-x, TKIE-x, TFIX-x, IP-LCM, ECPIR-3P, Exigo IP speakers. Exigo Network Amplifiers (only SIP mode and ICX- AlphaCom mode), and ENA-2060 (only in SIP mode) The firmware is delivered in a ZIP archive:.
Version:

  • vsft-6.2.x.x - Used for standard in-field upgrades

Date: 09.08.2021
Status: General Availability Compatibility: Pulse to IC-EDGE System
You can upgrade from Pulse (VS-IS 4.x) to IC-EDGE, but the whole system needs to run with the same Turbine software (VS-IS 5/6).
In an IC-EDGE System, INCA intercoms cannot be used as the Edge Controller.
TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices.
IMT 1.5 or newer can be used for station discovery and upgrade but must not be used to configure IC-EDGE.
Pulse to IC-EDGE Licenses
Pulse licenses will be honored in an IC-EGDE System. This means that when you upgrade firmware from VS-IS 4.x to 5.x/6.x your Pulse licenses will work for IC-EDGE.

Note icon The number of free VS station licenses has been increased from 16 to 32 in IC-EDGE. This means that you get an additional 16 VS stations to connect to in IC-EDGE


Note icon Both Multisite Trunking and VS-Client are free of charge in IC-EDGE


VSF-TURBINE 6.2.3.1

Fixed Issues - Turbine Intercom

MTN-3255 Calls going through 3CX SBC hangs up after 30 seconds

The record-route handling for strict routing did not work properly. This is now fixed.


VSF-TURBINE 6.2.3.0

Fixed Issues - Turbine Intercom

MTN-3359 Audio routing from Line-in to Speaker out not working

Fixed audio routing on devices supporting line in (TKIE and TFIE). This have been an issue on on all previous 6.x releases.

MTN-3339 Relays now return states without need to be triggered first

MTN-3334 TLS 1.1. support over https is removed from devices

MTN-3319 Offhook does no longer trigger factory reset count.


Known Issues

MTN-3299 TLS Private Keys not restored on Turbine stations

In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.

MTN-2692 Turbine stations won't register to ICX500 or Alphacom if the dash symbol is not removed from the Directory Number field.

In an unconfigured Turbine station there is a dash character in the Directory Number field in the "Main Settings menu. This dash symbol must be removed when the directory number is entered, else the station will fail to register.

MTN-2686 Outputs not working for Exigo amplifiers in SIP mode

GPO's does not work when exigo amplifiers are in SIP mode.

MTN-2363 Factory reset does not delete uploaded Script

All uploaded scripts should also be removed on Factory reset

MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream

H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.

MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR

RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream

MTN-2360 Client side forwarding does not work in SIP mode

Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.

MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer

Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert

MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.

When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.

MTN-2356 SNMP not working properly on TCIV under high CPU load

SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.

MTN-2339 Group call chime is not played on 3rd party SIP stations

Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.

MTN-2220 Default SNMP settings issue with firmware downgrade to 4.9

When downgrading from VSFT 4.11+ to 4.9 a factory reset is necessary if user wants to use default SNMP configuration. For custom snmp.conf file, re-upload with a custom snmp.conf file will fix the problem.

MTN-1073 Group call fails if system previously configured with ZAP

If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.