By default a station is playing a Notification Tone when receiving a Call Request. If a Call Request is received during a call, the tone will interrupt the call for a few seconds. To disable Notification Tone while in call, set the flag '''CRM Notification Tone''': [[Users_%26_Stations_(AlphaPro)#Station_Type_tab]]
 
By default a station is playing a Notification Tone when receiving a Call Request. If a Call Request is received during a call, the tone will interrupt the call for a few seconds. To disable Notification Tone while in call, set the flag '''CRM Notification Tone''': [[Users_%26_Stations_(AlphaPro)#Station_Type_tab]]
  
The original control room stations CRM III and CRM IV stations had an built in buzzer used for call request notification. Because of this the notification is not done through the loudspeaker when the station type in AlphaPro is set to "CRM".
+
=== Additional information ===
 
+
* Originally a station set to type "CRM" would not play any Notification Tone at all, as this was intended to be handled by an external buzzer.
With the introduction of [[Dual Display Station - 1007007000|Dual Display station]] and [[IP Flush Master - 1008031000|IP Flush master]] with 4 line display, the "CRM" station type is also used for these stations to get CRM functionality, but then no buzzer is available.
+
* From AlphaCom version 10.56 a "flag" was introduced, were the Notification Tone could be enabled. However, by default it was disabled.
 
+
* From AlphaCom version 11.5.3.4 this flag was by default enabled.
A station flag is introduced to allow normal mail notification also even when station type "CRM" is selected.
 
  
 
This flag can be set by this command:
 
This flag can be set by this command:
Line 31: Line 30:
  
 
[[File:CallReqNotif.PNG]]
 
[[File:CallReqNotif.PNG]]
 
See also '''CRM Notification Tone''': [[Users_%26_Stations_(AlphaPro)#Station_Type_tab]]
 
 
This flag was introduced in AMC software 10.56.
 
  
 
[[Category: ICX-AlphaCom features]]
 
[[Category: ICX-AlphaCom features]]
 
[[Category: AlphaCom features]]
 
[[Category: AlphaCom features]]

Revision as of 15:21, 20 May 2022

AI.png

A station has feature reminder activated when the station LED is flashing and a bleep tone is heard in the speaker every minute. "Feature reminder" is automatically activated when the station:


Additional information:

The Feature Reminder can be disabled per station from AlphaPro
  • The "feature reminder" status is cancelled from the station by dialling the station reset code 70.
  • The "feature reminder" status can be remotely cancelled by dialling "station number + 51 + 0" (require AMC 10.50 or later).
  • The "feature reminder" indication is by default enabled for all users, but can be enabled/disabled per station by the flag "Feature Reminder Wanted" in Users & Stations > User Preferences
  • The time between the bleep tone can be modified from the nvram editor in the TST console:
TST>>nvram - ex_profile.timeouts.th_bleep_pause = 600 (0x0258)

See also Urgent feature reminder

Call Request notification when Station type is set to "CRM"

By default a station is playing a Notification Tone when receiving a Call Request. If a Call Request is received during a call, the tone will interrupt the call for a few seconds. To disable Notification Tone while in call, set the flag CRM Notification Tone: Users_&_Stations_(AlphaPro)#Station_Type_tab

Additional information

  • Originally a station set to type "CRM" would not play any Notification Tone at all, as this was intended to be handled by an external buzzer.
  • From AlphaCom version 10.56 a "flag" was introduced, were the Notification Tone could be enabled. However, by default it was disabled.
  • From AlphaCom version 11.5.3.4 this flag was by default enabled.

This flag can be set by this command:

$SNV Q%op(%gnv(5,8,%1.phy,17),|,8192) W5 W8 W%1.phy W17

Where %1.phy must be replaced by the actual physical number of the Control Room station. Event 27/65 - ON can be used to set this flag. Example: Set "Call Request notification" flag for physical number 49: