Actions

Difference between revisions of "Turbine 4.11 - Release notes"

From Zenitel Wiki

(Technical Preview)
(SNOW-703 Trap support for CI on ENA2060)
 
(46 intermediate revisions by 4 users not shown)
Line 1: Line 1:
== Release info ==
+
Previous Release - [[Turbine 4.9 - Release notes]]
 +
 
 +
Next Release - [[Turbine 5.0 - Release notes]]
 +
 
 +
This document provides the release notes for VSF-Turbine 4.11 with incremental bug fix releases. The release notes for VSF-Turbine 4.11 describe new features, improvements and issues fixed after VSF-Turbine 4.9.
 +
 
 +
==Release info==
 
'''Name:''' VSF-Turbine <br>
 
'''Name:''' VSF-Turbine <br>
'''Description:''' VSF-Turbine is a firmware archive for all [[:Category:Turbine|Turbine Family Intercom stations]] including devices:
+
'''Description:''' VSF-Turbine is a firmware archive for all [[:Category:Stations#Turbine_stations|Turbine Family Intercom stations]] including devices:
'''TCIS-x''', '''TKIS-2''', '''TCIV-x''', '''TMIS-x''', '''TFIE-x''', '''TKIE-x''', '''TFIX-x''', '''ECPIR-3P''', '''ENA-2060AC''' (only in SIP mode), '''Exigo IP speakers''' and '''Exigo Network Amplifiers''' (AlphaCom mode only). <br>
+
'''TCIS-x''', '''TKIS-2''', '''TCIV-x''', '''TMIS-x''', '''TFIE-x''', '''TKIE-x''', '''TFIX-x''', '''ECPIR-3P''', '''IP-LCM unit''', '''ENA-2060DC''', '''Exigo IP speakers''' and '''Exigo Network Amplifiers''' (AlphaCom mode only). <br>
 
'''Version:''' The firmware is delivered in two different ZIP archives:
 
'''Version:''' The firmware is delivered in two different ZIP archives:
* '''vsft-4.11.2.x''' - Used for standard in-field upgrades
 
* '''vsft-prod-4.11.2.x''' - Used in production- and recovery upgrades. <br>
 
'''Version:''' 4.11.2.5 <br>
 
'''Date:''' 15.01.2019 <br>
 
'''Status:''' Limited Availability <br>
 
  
= VSF-TURBINE 4.11.2.5 =
+
*'''vsft-4.11.3.x''' - Used for standard in-field upgrades
==New Features - Turbine Intercom ==
+
*'''vsft-prod-4.11.3.x''' - Used in production- and recovery upgrades. <br>
=== SNOW-496 IP Station support for RFC3891 SIP "Replaces" Header ===  
+
 
 +
'''Version:''' 4.11.3.1 <br>
 +
'''Date:''' November 2019 <br>
 +
'''Status:'''General Availability <br>
 +
 
 +
=VSF-TURBINE 4.11.3.1=
 +
==Bugfixes and Improvements - Turbine Intercom==
 +
===MTN-2634 Factory reset on ENA2060 did not work===
 +
Now factory reset on ENA2060 works using input button 1.
 +
 
 +
===MTN-2389 SIP invite now contains RTP map listing each individual audio codec.===
 +
This will fix interoperability with some SBC's.
 +
 
 +
===MTN-2464 Industrial stations have factory reset over frontboard/gpio working correctly again===
 +
PTT can now be used again to factory reset. Also, resetting via frontboard is more reliable.
 +
 
 +
===MTN-2461 TKIE-3 handset PTT input did not work===
 +
TKIE-3 PTT handling is now fixed.
 +
 
 +
===MTN-2537 In SIP mode the station could crash on short messages===
 +
In SIP mode messages shorter than 4 bytes could crash the station. This has been fixed.
 +
 
 +
===MTN-2605 ENA2060 Continuous monitoring measurement updated first time after 1 hour===
 +
ENA2060 will now update continuous line monitoring measurements 5-15 seconds after successful calibration and then once per hour
 +
 
 +
===MTN-2533 Not possible to save changes on Video and Advanced video pages with HTTPS===
 +
Pressing Save on Video and Advanced video pages if HTTPS was used did not properly save changes. This has now been fixed.
 +
 
 +
===MTN-2594 DAK Call Setup priority not stored in station backup===
 +
Call Setup priority was not preserved during upgrade for inputs. This is now fixed.
 +
 
 +
===MTN-2433 IP-LCM external relays shown on Webcall form===
 +
IP-LCM external relays are now properly shown on Webcall form
 +
 
 +
===MTN-2447 IP-LCM in Pulse mode has wrong number of relays in Advanced Output Handler===
 +
The number of relays in the advanced output handler configuration is now corrected.
 +
 
 +
===MTN-2536 Syslog TCP port===
 +
Syslog suggests a default TCP port, but you had to manually enter it in order to get syslog working. Now you don't need to enter the port anymore.
 +
 
 +
===MTN-2456 Reading IP address on ENA2060 did not work===
 +
Reading IP address on ENA2060 using an input now works.
 +
 
 +
===MTN-2507 Support for updated camera board kernel on TCIV units===
 +
TCIV now supports updated camera board kernel which is applied in production, it's not necessary to update camera board kernel on already produced TCIV stations. TCIV stations with camera board kernel version 3716, can only be used with firmware version 4.11.3.1, 5.1.3.0 and newer. It's not possible to downgrade these stations to older firmware versions.
 +
 
 +
===MTN-2481 TFTP provisioning would sometimes look for wrong filename if SIP domain has not been configured===
 +
TFTP provisioning would sometimes look for wrong file with IPv6 address instead of IPv4 address if the primary SIP domain had not been configured. This has been fixed.
 +
 
 +
===MTN-2312 Turbine devices not booting completely===
 +
If a Turbine device has gotten an IP address from a DHCP server, and then reboots without contact to the DHCP server, the Turbine will go into cyclic reboot until it gets in contact with DHCP server again. This has now been fixed.
 +
 
 +
==Security fixes and improvements==
 +
===MTN-2496 HTTP call and relay API is disabled by default.===
 +
User can enable HTTP API via web call page. This also affect users using Virtual I/O script that leverages this API, they will have to enable it on receiving station.
 +
 
 +
<br>
 +
 
 +
==Known Issues==
 +
===MTN-2363 Factory reset does not delete uploaded Script===
 +
All uploaded scripts should also be removed on Factory reset
 +
 
 +
===MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream===
 +
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
 +
 
 +
===MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR===
 +
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
 +
 
 +
===MTN-2360 Client side forwarding does not work in SIP mode===
 +
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
 +
 
 +
===MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer===
 +
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert
 +
 
 +
===MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.===
 +
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
 +
 
 +
===MTN-2356 SNMP not working properly on TCIV under high CPU load===
 +
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
 +
 
 +
===MTN-2339 Group call chime is not played on 3rd party SIP stations===
 +
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.
 +
 
 +
===MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working===
 +
On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) is not working. Other keys are functional.
 +
 
 +
===MTN-1073 Group call fails if system previously configured with ZAP===
 +
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.
 +
 
 +
<br>
 +
 
 +
=VSF-TURBINE 4.11.3.0=
 +
==New Features - Turbine Intercom==
 +
===SNOW-496 IP Station support for RFC3891 SIP "Replaces" Header===  
 
The IP Station (Turbine and INCA) now support Reinvite / INVITE with replaces, which is quite common function used in SIP environments. The needed function is described in RFC3891.
 
The IP Station (Turbine and INCA) now support Reinvite / INVITE with replaces, which is quite common function used in SIP environments. The needed function is described in RFC3891.
  
=== SNOW-818 Keep-alive for improved VoIP NAT traversal ===  
+
===SNOW-818 Keep-alive for improved VoIP NAT traversal===  
 
NAT keep-alive is a feature that sends very tiny UDP data packets from a VoIP client to the router to show that the port is still in use.  Turbine and INCA are now sending keep-alives every 25 seconds if have enabled "NAT Keep Alive" under Call Settings.  
 
NAT keep-alive is a feature that sends very tiny UDP data packets from a VoIP client to the router to show that the port is still in use.  Turbine and INCA are now sending keep-alives every 25 seconds if have enabled "NAT Keep Alive" under Call Settings.  
  
=== SNOW-330 IP Multicast audio support for Pulse Intercom===  
+
===SNOW-330 IP Multicast audio support for Pulse Intercom===  
 
Turbine and INCA IP intercom stations now support IP multicast audio when configured in Pulse mode. Previously, only SIP mode was supported. Up to 10 multicast IP addresses can be configured.
 
Turbine and INCA IP intercom stations now support IP multicast audio when configured in Pulse mode. Previously, only SIP mode was supported. Up to 10 multicast IP addresses can be configured.
  
=== SNOW-192 Chinese font on Turbine OLED display===  
+
===SNOW-192 Chinese font on Turbine OLED display===  
 
Turbine now supports Chinese language characters with new font package. New vsf-chinese-font_x.x.x.x_armel.ipk package is made, which can be installed on the turbine (download can be found on our Wiki)
 
Turbine now supports Chinese language characters with new font package. New vsf-chinese-font_x.x.x.x_armel.ipk package is made, which can be installed on the turbine (download can be found on our Wiki)
  
=== SNOW-871 TCIV-5 firmware support===  
+
===SNOW-871 TCIV-5 firmware support===  
 
Turbine firmware now supports a new TCIV-5 Turbine IP station model.
 
Turbine firmware now supports a new TCIV-5 Turbine IP station model.
  
=== SNOW-1165 Image quality improvements for TCIV===  
+
===SNOW-1165 Image quality improvements for TCIV===  
 
Low-level optimizations were made for AEWB engine (Automatic Exposure and White Balancing) resulting in following image quality improvements: Better low-light performance, Better overall color accuracy and contrast, Smoother dynamic dark-light transitions.
 
Low-level optimizations were made for AEWB engine (Automatic Exposure and White Balancing) resulting in following image quality improvements: Better low-light performance, Better overall color accuracy and contrast, Smoother dynamic dark-light transitions.
  
=== SNOW-83 ONVIF Profile-S support on TCIV===  
+
===SNOW-83 ONVIF Profile-S support on TCIV===  
 
TCIV now fully supports and is compliant with ONVIF Profile-S specification.  As a standard in the industry, Profile-S can be used to integrate with a variety of VMS and NVR products.  
 
TCIV now fully supports and is compliant with ONVIF Profile-S specification.  As a standard in the industry, Profile-S can be used to integrate with a variety of VMS and NVR products.  
  
=== SNOW-1166 RTSP support for TCIV video stream ===  
+
===SNOW-1166 RTSP support for TCIV video stream===  
 
RTSP is an industry standard network control protocol for establishing and controlling media streams. TCIV now comes with a full support for RTSP video streams.  
 
RTSP is an industry standard network control protocol for establishing and controlling media streams. TCIV now comes with a full support for RTSP video streams.  
  
=== SNOW-1169 Dual stream functionality on TCIV===  
+
===SNOW-1169 Dual stream functionality on TCIV===  
 
TCIV now supports dual-streaming functionality where two independent video streams can be separately initiated and controlled. Streams can be configured with different protocols (SIP, RTSP, ONVIF, HTTP), different codec and resolution, and are both lip-synced if audio and video is being used - using the industry standard RTCP protocol.
 
TCIV now supports dual-streaming functionality where two independent video streams can be separately initiated and controlled. Streams can be configured with different protocols (SIP, RTSP, ONVIF, HTTP), different codec and resolution, and are both lip-synced if audio and video is being used - using the industry standard RTCP protocol.
  
=== SNOW-1167 RTSP audio stream support for all Turbine devices===  
+
===SNOW-1167 RTSP audio stream support for all Turbine devices===  
 
RTSP is an industry standard network control protocol for establishing and controlling media streams. All Turbine intercom devices and kits now fully support RTSP for outgoing audio streams.  
 
RTSP is an industry standard network control protocol for establishing and controlling media streams. All Turbine intercom devices and kits now fully support RTSP for outgoing audio streams.  
  
=== SNOW-1168 Lip-sync of Audio and Video on TCIV===  
+
===SNOW-1168 Lip-sync of Audio and Video on TCIV===  
 
Audio and Video streams initiated using ONVIF or RTSP protocols are lip-synced for both streaming and recording, implemented using the industry standard RTP Control Protocol (RTCP).
 
Audio and Video streams initiated using ONVIF or RTSP protocols are lip-synced for both streaming and recording, implemented using the industry standard RTP Control Protocol (RTCP).
  
==New Features - Technical Preview  ==
+
===SNOW-1013 Pulse systems can now be integrated with Exigo system===
=== SNOW-330 IP Multicast audio support for Pulse Intercom===
+
Using the SIP interface on Exigo systems allows for integration both ways to pulse systems. Exigo 1.4.3.0 or newer required.
Turbine and INCA IP intercom stations now support IP multicast audio when configured in Pulse mode. Previously, only SIP mode was supported. Up to 10 multicast IP addresses can be configured.
+
 
 +
===SNOW-2301 Added "Stop Message" as an audio message option===
 +
"Stop Message" can be used to stop other audio messages. It has the same options as other audio messages.
 +
 
 +
<br>
 +
 
 +
==New Features - Exigo Amplifiers==
 +
===SNOW-1014 Exigo Amplifiers now support distributed automatic volume controllers===  
 +
Distributed Automatic Volume Controllers are TKIS-2 kits which measures background noise in an area and can adjust the volume settings for an amplifier or IP speaker so that the audio is audiable above the noise
 +
 
 +
===SNOW-1012 ENA2100-AC is now supported in Alphacom systems===
 +
 
 +
*Advanced line monitoring and Lets supported
 +
*Hardware audio bypass supported
 +
*2 control outputs with 200mA@24Vdc each
 +
*2 control inputs
 +
*Supported in Exigo mode and Alphacom systems
 +
 
 +
<br>
 +
 
 +
==Bugfixes and Improvements - Turbine Intercom==
 +
===MTN-2257 Audio Input Source option removed for Compact Turbine stations===
 +
Audio Input Source configuration option was removed for Compact Turbine stations because they don't have a physical Line In connector, so this configuration option did not have any effect on them.
 +
 
 +
===MTN-1527 IP Multicast Audio audible interruptions===
 +
It was possible to hear audible effects during IP Multicast audio playback, and with a relatively high interval rate. This is now fixed.
 +
 
 +
===MTN-1930 TFIE-6 does not display AlphaCom status-messages in Idle===
 +
AlphaCom status messages did not work correctly on TFIE-6. For example, it was not possible to see if a TFIE-6 is forwarded(71,72) or marked absent(77x).
 +
 
 +
===MTN-2258 ECPIR-3P M-key does not perform key-release action===
 +
ECPIR-3P M-key would not allow to exit the call if DAK In call was configured to exit on the M-key release
 +
 
 +
===MTN-1974 Sound detection on Turbine is not triggered properly===
 +
Sound Detection is never triggered on, but "DAK off" is reported. Fixed
 +
 
 +
===MTN-1498 Group call fails after Pulse Server reboots and takes ~ 5 min to work again===
 +
The registration information is now properly stored in the Pulse server and Group call shall work immediately after server restart.
 +
 
 +
===MTN-2314 Using overlap dialing started ringing audio message for each digit pressed===
 +
When dialing on keyboard using overlap dialing, the ringing audio message would get executed for each digit pressed instead of only when call actually was ringing.
 +
 
 +
===MTN-2313 Audio message executes twice when ringing===
 +
If you configure an audio message to play during ringing, it will start playing, then shortly after restart again. This is now fixed.
 +
 
 +
===MTN-2259 Configured PTT\M-Key action when using EMMAR-1H===
 +
When using EMMAR-1H the DAK call configuration for M/PPT key couldn't be initialized if the In call button configuration for the M/PTT was End call
 +
 
 +
===MTN-2342 Issue with using "&" character in display text on TCIV-6 and TCIS-6===
 +
Now it is possible to use the "&" symbol as part of the display text on TCIV-6 and TCIS-6.
 +
 
 +
===MTN-2122 In HD Audio mode the station would report missing RTP===
 +
In HD Audio mode the station would incorrectly report missing RTP when it is meant to only send audio. This has been fixed.
 +
 
 +
===MTN-2086 AEC Performance Improvements - Reduced Echo Artifacts===
 +
By tuning the Acoustic Echo Cancellation algorithm options we have reduced the level of produced Echo artifacts on Turbine stations at high-level speaker outputs.
 +
 
 +
===MTN-2274 Using ZAP to set volume did not work===
 +
ZAP can now be used to set volume for amplifiers and Turbine
 +
 
 +
===MTN-2341 Custom frontboard configuration now supports up to 11 DAK keys, from previous 8.===  
 +
All 11 physical DAK keys can now be configured when custom frontobard is used.
 +
 
 +
===MTN-2085 Far-End signal limiter on Turbine===
 +
Far-End signal Limiter filter is designed to avoid powerful Far-End signal bringing the station to PoE shutdown as well as try to avoid Far-End Signal clipping and distortions.
 +
 
 +
===MTN-2019 TCIV displays incorrect default image resolution for MJPEG HTTP===
 +
When opening HTTP MJPEG video stream in a web browser (http://IP-Address:8090) the video is displayed in smaller resolution then a defined default of 480p., this is now fixed by properly applying configured resolution.
 +
 
 +
===SNOW-313 RTSP support for TCIV H.264 stream (AlphaCom)===
 +
Added RTSP H.264 support on ITSV-1 to initiate video stream from TCIV in AlphaCom mode
 +
 
 +
===SNOW-887 Video setup mode "Cisco" removed===
 +
Due to the fixes in video stream FPS stability the "Cisco" video setup mode was made obsolete and therefore removed from StationWeb options
 +
 
 +
<br>
 +
 
 +
 
 +
==Bugfixes and Improvements - Exigo Amplifiers==
 +
===MTN-2246 Suspend monitoring not always working for ENA in AlphaCom===
 +
Certain directory number configurations could previously stop suspend monitoring from working when using Exigo network amplifiers (ENA) in AlphaCom mode. This has been fixed.
 +
 
 +
 
 +
<br>
 +
 
 +
==Security fixes and improvements==
 +
===MTN-2366 Basic MJPEG HTTP authentication should be enabled by default===
 +
Now the option to Enable basic HTTP authentication for HTTP MJPEG is enabled by default.
 +
 
 +
===MTN-2102 Password on Pulse server Directory settings shown as plain text===
 +
Password on Pulse server Directory settings page was displayed as plain text. Now it is displayed as standard HTML password field.
 +
 
 +
<br>
 +
 
 +
==Known Issues==
 +
===MTN-2363 Factory reset does not delete uploaded Script===
 +
All uploaded scripts should also be removed on Factory reset
 +
 
 +
===MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream===
 +
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
 +
 
 +
===MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR===
 +
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
 +
 
 +
===MTN-2360 Client side forwarding does not work in SIP mode===
 +
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
 +
 
 +
===MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer===
 +
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert
 +
 
 +
===MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.===
 +
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
 +
 
 +
===MTN-2356 SNMP not working properly on TCIV under high CPU load===
 +
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
 +
 
 +
===MTN-2339 Group call chime is not played on 3rd party SIP stations===
 +
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.
 +
 
 +
===MTN-2312 Turbine devices not booting completely===
 +
If a Turbine device has gotten a IP address from a DHCP server, and then reboots without contact to the DHCP server, the Turbine will go into cyclic reboot until it gets in contact with DHCP server again.
 +
 
 +
Workaround: Make sure a DHCP server is available or factory reset with static IP address.
 +
 
 +
===MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working===
 +
On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) is not working. Other keys are functional.
 +
 
 +
===MTN-1073 Group call fails if system previously configured with ZAP===
 +
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.
 +
 
 +
<br>
 +
 
 +
=VSF-TURBINE 4.10.3.0=
 +
==New Features - Turbine Intercom==
 +
===SNOW-421 Advanced GPO configuration for Pulse and SIP===
 +
Turbine now has option to use standard Relay configuration or use the new and more Advanced GPO (output) configuration.
 +
 
 +
===SNOW-1011 IP-LCM support in SIP, Pulse and Alphacom===
 +
IP-LCM is now supported in SIP, Pulse and Alphacom systems. This device has:
 +
 
 +
*8 robust high power relays
 +
*8 robust inputs
 +
*Powered via the TKIS-2 kit with PoE, PoE inject or external power supply
 +
*All connections and features from the TKIS-2 kit available
 +
 
 +
==New Features - Exigo Amplifiers==
 +
===SNOW-595 Exigo Network Amplifiers can now fall back to routing line input in cases where servers are unavailable===
 +
 
 +
<br>
 +
 
 +
==Bugfixes and Improvements - Turbine Intercom==
 +
===MTN-1709 Fault led on all Turbine industrial stations, Turbine EX stations and Exigo Access panels can now be configured with custom behavior in Alphacom===
 +
 
 +
===SNOW-319 TKIE-3 support in Turbine firmware===
 +
TKIE-3 is now supported in Turbine firmware
 +
 
 +
===SNOW-321 Implement Distributed AVC in SIP Mode===
 +
All "Turbine Devices" can be AVC Source (Ambient audio listener) or AVC destination.
 +
 
 +
===SNOW-328 Adjust volume using SIP OPTIONS with X-Header===
 +
It is now possible to adjust volume using SIP OPTIONS with x-header by adding x-volume-level-override. The function will override the configured station volume
 +
 
 +
===SNOW-552 Syslog support===
 +
Turbine now supports logging to the syslog server. Up to 3 syslog server destinations are supported
 +
 
 +
===SNOW-592 AGC for line/mic in===
 +
Automatic Gain Control now works for Line/Mic in depending on configured input selection
 +
 
 +
===SNOW-1173 New call functions in SIP===
 +
It is now possible to put call on hold or defer a call using DAK configuration
  
== Bugfixes and Improvements ==
 
  
==Known Issues ==
+
==Bugfixes and Improvements - Exigo Amplifiers==
 +
===SNOW-340 ENA2060 Line Monitoring improved===
 +
Changes made to line monitoring of ENA2060 to make it more robust
  
 +
===SNOW-183 SNMP Traps on Exigo amplifiers===
 +
Device status and fault messages can be sent as SNMP Traps.
  
 +
===SNOW-562 ENA-2060 does not report disabled channel===
 +
ENA2060 will now correctly report channel state when one of the channels are disabled manually
  
 +
===SNOW-111 Detailed channel state in SNMP MIB===
 +
Detailed information about the actual state of the audio channel is now included in the SNMP MIB.
  
 +
===SNOW-703 Trap support for CI on ENA2060===
 +
Control inputs on ENA2060 can now generate a trap for SNMP with a custom message.
  
 
[[Category: Release notes]]
 
[[Category: Release notes]]

Latest revision as of 09:17, 23 June 2022

Previous Release - Turbine 4.9 - Release notes

Next Release - Turbine 5.0 - Release notes

This document provides the release notes for VSF-Turbine 4.11 with incremental bug fix releases. The release notes for VSF-Turbine 4.11 describe new features, improvements and issues fixed after VSF-Turbine 4.9.

Contents

Release info

Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices: TCIS-x, TKIS-2, TCIV-x, TMIS-x, TFIE-x, TKIE-x, TFIX-x, ECPIR-3P, IP-LCM unit, ENA-2060DC, Exigo IP speakers and Exigo Network Amplifiers (AlphaCom mode only).
Version: The firmware is delivered in two different ZIP archives:

  • vsft-4.11.3.x - Used for standard in-field upgrades
  • vsft-prod-4.11.3.x - Used in production- and recovery upgrades.

Version: 4.11.3.1
Date: November 2019
Status:General Availability

VSF-TURBINE 4.11.3.1

Bugfixes and Improvements - Turbine Intercom

MTN-2634 Factory reset on ENA2060 did not work

Now factory reset on ENA2060 works using input button 1.

MTN-2389 SIP invite now contains RTP map listing each individual audio codec.

This will fix interoperability with some SBC's.

MTN-2464 Industrial stations have factory reset over frontboard/gpio working correctly again

PTT can now be used again to factory reset. Also, resetting via frontboard is more reliable.

MTN-2461 TKIE-3 handset PTT input did not work

TKIE-3 PTT handling is now fixed.

MTN-2537 In SIP mode the station could crash on short messages

In SIP mode messages shorter than 4 bytes could crash the station. This has been fixed.

MTN-2605 ENA2060 Continuous monitoring measurement updated first time after 1 hour

ENA2060 will now update continuous line monitoring measurements 5-15 seconds after successful calibration and then once per hour

MTN-2533 Not possible to save changes on Video and Advanced video pages with HTTPS

Pressing Save on Video and Advanced video pages if HTTPS was used did not properly save changes. This has now been fixed.

MTN-2594 DAK Call Setup priority not stored in station backup

Call Setup priority was not preserved during upgrade for inputs. This is now fixed.

MTN-2433 IP-LCM external relays shown on Webcall form

IP-LCM external relays are now properly shown on Webcall form

MTN-2447 IP-LCM in Pulse mode has wrong number of relays in Advanced Output Handler

The number of relays in the advanced output handler configuration is now corrected.

MTN-2536 Syslog TCP port

Syslog suggests a default TCP port, but you had to manually enter it in order to get syslog working. Now you don't need to enter the port anymore.

MTN-2456 Reading IP address on ENA2060 did not work

Reading IP address on ENA2060 using an input now works.

MTN-2507 Support for updated camera board kernel on TCIV units

TCIV now supports updated camera board kernel which is applied in production, it's not necessary to update camera board kernel on already produced TCIV stations. TCIV stations with camera board kernel version 3716, can only be used with firmware version 4.11.3.1, 5.1.3.0 and newer. It's not possible to downgrade these stations to older firmware versions.

MTN-2481 TFTP provisioning would sometimes look for wrong filename if SIP domain has not been configured

TFTP provisioning would sometimes look for wrong file with IPv6 address instead of IPv4 address if the primary SIP domain had not been configured. This has been fixed.

MTN-2312 Turbine devices not booting completely

If a Turbine device has gotten an IP address from a DHCP server, and then reboots without contact to the DHCP server, the Turbine will go into cyclic reboot until it gets in contact with DHCP server again. This has now been fixed.

Security fixes and improvements

MTN-2496 HTTP call and relay API is disabled by default.

User can enable HTTP API via web call page. This also affect users using Virtual I/O script that leverages this API, they will have to enable it on receiving station.


Known Issues

MTN-2363 Factory reset does not delete uploaded Script

All uploaded scripts should also be removed on Factory reset

MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream

H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.

MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR

RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream

MTN-2360 Client side forwarding does not work in SIP mode

Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.

MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer

Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert

MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.

When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.

MTN-2356 SNMP not working properly on TCIV under high CPU load

SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.

MTN-2339 Group call chime is not played on 3rd party SIP stations

Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.

MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working

On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) is not working. Other keys are functional.

MTN-1073 Group call fails if system previously configured with ZAP

If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.


VSF-TURBINE 4.11.3.0

New Features - Turbine Intercom

SNOW-496 IP Station support for RFC3891 SIP "Replaces" Header

The IP Station (Turbine and INCA) now support Reinvite / INVITE with replaces, which is quite common function used in SIP environments. The needed function is described in RFC3891.

SNOW-818 Keep-alive for improved VoIP NAT traversal

NAT keep-alive is a feature that sends very tiny UDP data packets from a VoIP client to the router to show that the port is still in use. Turbine and INCA are now sending keep-alives every 25 seconds if have enabled "NAT Keep Alive" under Call Settings.

SNOW-330 IP Multicast audio support for Pulse Intercom

Turbine and INCA IP intercom stations now support IP multicast audio when configured in Pulse mode. Previously, only SIP mode was supported. Up to 10 multicast IP addresses can be configured.

SNOW-192 Chinese font on Turbine OLED display

Turbine now supports Chinese language characters with new font package. New vsf-chinese-font_x.x.x.x_armel.ipk package is made, which can be installed on the turbine (download can be found on our Wiki)

SNOW-871 TCIV-5 firmware support

Turbine firmware now supports a new TCIV-5 Turbine IP station model.

SNOW-1165 Image quality improvements for TCIV

Low-level optimizations were made for AEWB engine (Automatic Exposure and White Balancing) resulting in following image quality improvements: Better low-light performance, Better overall color accuracy and contrast, Smoother dynamic dark-light transitions.

SNOW-83 ONVIF Profile-S support on TCIV

TCIV now fully supports and is compliant with ONVIF Profile-S specification. As a standard in the industry, Profile-S can be used to integrate with a variety of VMS and NVR products.

SNOW-1166 RTSP support for TCIV video stream

RTSP is an industry standard network control protocol for establishing and controlling media streams. TCIV now comes with a full support for RTSP video streams.

SNOW-1169 Dual stream functionality on TCIV

TCIV now supports dual-streaming functionality where two independent video streams can be separately initiated and controlled. Streams can be configured with different protocols (SIP, RTSP, ONVIF, HTTP), different codec and resolution, and are both lip-synced if audio and video is being used - using the industry standard RTCP protocol.

SNOW-1167 RTSP audio stream support for all Turbine devices

RTSP is an industry standard network control protocol for establishing and controlling media streams. All Turbine intercom devices and kits now fully support RTSP for outgoing audio streams.

SNOW-1168 Lip-sync of Audio and Video on TCIV

Audio and Video streams initiated using ONVIF or RTSP protocols are lip-synced for both streaming and recording, implemented using the industry standard RTP Control Protocol (RTCP).

SNOW-1013 Pulse systems can now be integrated with Exigo system

Using the SIP interface on Exigo systems allows for integration both ways to pulse systems. Exigo 1.4.3.0 or newer required.

SNOW-2301 Added "Stop Message" as an audio message option

"Stop Message" can be used to stop other audio messages. It has the same options as other audio messages.


New Features - Exigo Amplifiers

SNOW-1014 Exigo Amplifiers now support distributed automatic volume controllers

Distributed Automatic Volume Controllers are TKIS-2 kits which measures background noise in an area and can adjust the volume settings for an amplifier or IP speaker so that the audio is audiable above the noise

SNOW-1012 ENA2100-AC is now supported in Alphacom systems

  • Advanced line monitoring and Lets supported
  • Hardware audio bypass supported
  • 2 control outputs with 200mA@24Vdc each
  • 2 control inputs
  • Supported in Exigo mode and Alphacom systems


Bugfixes and Improvements - Turbine Intercom

MTN-2257 Audio Input Source option removed for Compact Turbine stations

Audio Input Source configuration option was removed for Compact Turbine stations because they don't have a physical Line In connector, so this configuration option did not have any effect on them.

MTN-1527 IP Multicast Audio audible interruptions

It was possible to hear audible effects during IP Multicast audio playback, and with a relatively high interval rate. This is now fixed.

MTN-1930 TFIE-6 does not display AlphaCom status-messages in Idle

AlphaCom status messages did not work correctly on TFIE-6. For example, it was not possible to see if a TFIE-6 is forwarded(71,72) or marked absent(77x).

MTN-2258 ECPIR-3P M-key does not perform key-release action

ECPIR-3P M-key would not allow to exit the call if DAK In call was configured to exit on the M-key release

MTN-1974 Sound detection on Turbine is not triggered properly

Sound Detection is never triggered on, but "DAK off" is reported. Fixed

MTN-1498 Group call fails after Pulse Server reboots and takes ~ 5 min to work again

The registration information is now properly stored in the Pulse server and Group call shall work immediately after server restart.

MTN-2314 Using overlap dialing started ringing audio message for each digit pressed

When dialing on keyboard using overlap dialing, the ringing audio message would get executed for each digit pressed instead of only when call actually was ringing.

MTN-2313 Audio message executes twice when ringing

If you configure an audio message to play during ringing, it will start playing, then shortly after restart again. This is now fixed.

MTN-2259 Configured PTT\M-Key action when using EMMAR-1H

When using EMMAR-1H the DAK call configuration for M/PPT key couldn't be initialized if the In call button configuration for the M/PTT was End call

MTN-2342 Issue with using "&" character in display text on TCIV-6 and TCIS-6

Now it is possible to use the "&" symbol as part of the display text on TCIV-6 and TCIS-6.

MTN-2122 In HD Audio mode the station would report missing RTP

In HD Audio mode the station would incorrectly report missing RTP when it is meant to only send audio. This has been fixed.

MTN-2086 AEC Performance Improvements - Reduced Echo Artifacts

By tuning the Acoustic Echo Cancellation algorithm options we have reduced the level of produced Echo artifacts on Turbine stations at high-level speaker outputs.

MTN-2274 Using ZAP to set volume did not work

ZAP can now be used to set volume for amplifiers and Turbine

MTN-2341 Custom frontboard configuration now supports up to 11 DAK keys, from previous 8.

All 11 physical DAK keys can now be configured when custom frontobard is used.

MTN-2085 Far-End signal limiter on Turbine

Far-End signal Limiter filter is designed to avoid powerful Far-End signal bringing the station to PoE shutdown as well as try to avoid Far-End Signal clipping and distortions.

MTN-2019 TCIV displays incorrect default image resolution for MJPEG HTTP

When opening HTTP MJPEG video stream in a web browser (http://IP-Address:8090) the video is displayed in smaller resolution then a defined default of 480p., this is now fixed by properly applying configured resolution.

SNOW-313 RTSP support for TCIV H.264 stream (AlphaCom)

Added RTSP H.264 support on ITSV-1 to initiate video stream from TCIV in AlphaCom mode

SNOW-887 Video setup mode "Cisco" removed

Due to the fixes in video stream FPS stability the "Cisco" video setup mode was made obsolete and therefore removed from StationWeb options



Bugfixes and Improvements - Exigo Amplifiers

MTN-2246 Suspend monitoring not always working for ENA in AlphaCom

Certain directory number configurations could previously stop suspend monitoring from working when using Exigo network amplifiers (ENA) in AlphaCom mode. This has been fixed.



Security fixes and improvements

MTN-2366 Basic MJPEG HTTP authentication should be enabled by default

Now the option to Enable basic HTTP authentication for HTTP MJPEG is enabled by default.

MTN-2102 Password on Pulse server Directory settings shown as plain text

Password on Pulse server Directory settings page was displayed as plain text. Now it is displayed as standard HTML password field.


Known Issues

MTN-2363 Factory reset does not delete uploaded Script

All uploaded scripts should also be removed on Factory reset

MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream

H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.

MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR

RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream

MTN-2360 Client side forwarding does not work in SIP mode

Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.

MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer

Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert

MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.

When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.

MTN-2356 SNMP not working properly on TCIV under high CPU load

SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.

MTN-2339 Group call chime is not played on 3rd party SIP stations

Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.

MTN-2312 Turbine devices not booting completely

If a Turbine device has gotten a IP address from a DHCP server, and then reboots without contact to the DHCP server, the Turbine will go into cyclic reboot until it gets in contact with DHCP server again.

Workaround: Make sure a DHCP server is available or factory reset with static IP address.

MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working

On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) is not working. Other keys are functional.

MTN-1073 Group call fails if system previously configured with ZAP

If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.


VSF-TURBINE 4.10.3.0

New Features - Turbine Intercom

SNOW-421 Advanced GPO configuration for Pulse and SIP

Turbine now has option to use standard Relay configuration or use the new and more Advanced GPO (output) configuration.

SNOW-1011 IP-LCM support in SIP, Pulse and Alphacom

IP-LCM is now supported in SIP, Pulse and Alphacom systems. This device has:

  • 8 robust high power relays
  • 8 robust inputs
  • Powered via the TKIS-2 kit with PoE, PoE inject or external power supply
  • All connections and features from the TKIS-2 kit available

New Features - Exigo Amplifiers

SNOW-595 Exigo Network Amplifiers can now fall back to routing line input in cases where servers are unavailable


Bugfixes and Improvements - Turbine Intercom

MTN-1709 Fault led on all Turbine industrial stations, Turbine EX stations and Exigo Access panels can now be configured with custom behavior in Alphacom

SNOW-319 TKIE-3 support in Turbine firmware

TKIE-3 is now supported in Turbine firmware

SNOW-321 Implement Distributed AVC in SIP Mode

All "Turbine Devices" can be AVC Source (Ambient audio listener) or AVC destination.

SNOW-328 Adjust volume using SIP OPTIONS with X-Header

It is now possible to adjust volume using SIP OPTIONS with x-header by adding x-volume-level-override. The function will override the configured station volume

SNOW-552 Syslog support

Turbine now supports logging to the syslog server. Up to 3 syslog server destinations are supported

SNOW-592 AGC for line/mic in

Automatic Gain Control now works for Line/Mic in depending on configured input selection

SNOW-1173 New call functions in SIP

It is now possible to put call on hold or defer a call using DAK configuration


Bugfixes and Improvements - Exigo Amplifiers

SNOW-340 ENA2060 Line Monitoring improved

Changes made to line monitoring of ENA2060 to make it more robust

SNOW-183 SNMP Traps on Exigo amplifiers

Device status and fault messages can be sent as SNMP Traps.

SNOW-562 ENA-2060 does not report disabled channel

ENA2060 will now correctly report channel state when one of the channels are disabled manually

SNOW-111 Detailed channel state in SNMP MIB

Detailed information about the actual state of the audio channel is now included in the SNMP MIB.

SNOW-703 Trap support for CI on ENA2060

Control inputs on ENA2060 can now generate a trap for SNMP with a custom message.