(37 intermediate revisions by 2 users not shown) |
Line 1: |
Line 1: |
− | [[File:IP Video Door Station.PNG|thumb|600px|IP Video Station, item 1401110200]] | + | {{obsolete}} |
| + | {{APS}} |
| + | [[File:IP Video Door Station.PNG|thumb|600px|IP Video Station with Axis camera, item 1401110200]] |
| | | |
− | '''Camera Type: Axis'''
| + | == Connections == |
| + | * [[IP Video Doorstation Connections|Intercom connections]] |
| | | |
− | ==Highlights== | + | ==Configuration== |
− | * Robust housing with Aluminium frontplate
| + | The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure. |
− | * IP65 protection to front
| |
− | * PoE Powered from one IP network cable
| |
− | * IP HD Video camera BY AXIS
| |
− | * AlphaCom Substation with all CCoIP features
| |
− | * Relay output for remote control, e.g. doors, signal lamps and gates
| |
− | * Button with bi-colour LED ring
| |
| | | |
− | ==Additional Documentation==
| + | General configuration: |
− | For more documentation please see http://www.zenitel.com/product/product/ip-vandal-resistant-video-station
| + | * [[IP Station Configuration - ICX-AlphaCom mode]] |
| + | * [[SIP Intercom - Web Interface|IP Station Configuration - SIP mode]] |
| + | * [[IP Station Configuration - Pulse mode]] |
| | | |
− | ==Installation==
| + | Station specific configuration: |
− | * Default IP adresses:
| + | * [[Axis Camera Configuration]] |
− | ** Audio module: 169.254.1.100 (admin/alphaadmin)
| |
− | ** Camera module: 169.254.1.101 (admin/1234) | |
− | See article: [[IP Station Installation]]
| |
| | | |
− | ==Station Board Connectors and LED Indications== | + | == Restore Factory Defaults and Software Upgrade == |
− | See article: [[IP_Station_Board_Connections_and_Indications#1401110100.2F1401110100|IP Station Board Connections and Indications]]
| + | * [[INCA Station Restore Factory Defaults|Factory reset of the intercom station]] |
| + | * [[INCA Station Software upgrade|Upgrade via the station web interface]] |
| + | * [[IMT - Discover & Upgrade|Upgrade using the IMT tool]] |
| + | * Axis Camera upgrade |
| + | * [[Automatic Software Upgrade|Automatic Software Upgrade (SIP mode only)]] |
| + | * [[:Category:INCA Release notes|Software Release Notes]] |
| | | |
− | == IP Station Configuration == | + | == Connectors, Indicators and Dimensions == |
− | See article: [[IP_Station_Configuration#Configuration_in_IP-StationWeb|IP Station Configuration]]
| + | * [[INCA Video Doorstation Board Connectors|Board Connectors]] |
| + | * [[INCA Video Doorstation LED Indicators|Station LED Indications]] |
| + | * [[INCA Substation PCB LED Indicators|PCB LED Indications]] |
| + | * [[IP Video Doorstation Dimensions & Mounting Instructions|Dimensions]] |
| | | |
− | ==Reset to factory settings== | + | == Accessories == |
− | *Factory Settings of Audio Module: [[IP_Station_Restore_Factory_Defaults|IP Station Restore Factory Defaults]] | + | * [[Back box flush mount - 1401199101]] |
− | *Factory Settings of Camera Module: [[#Axis Factory Reset]] | + | * [[Back box on wall mount - 1401199111]] |
| + | * [[Protection Roof - 1401199112]] |
| | | |
− | ==Software Upgrade== | + | == Additional information == |
− | See article: [[IP Station Software upgrade]]
| + | * [http://www.zenitel.com/product/ip-vandal-resistant-video-station Additional Documentation on Zenitel.com] |
| | | |
− | ==Dimensions==
| |
− | See article: [[IP_Stations_Dimensions_%26_Mounting_Instructions#IP_Video_Door_Station|IP Stations Dimensions and Mounting Instructions]]
| |
| | | |
− | =Camera Configuration=
| + | [[Category: Discontinued Stations]] |
− | | |
− | Connect to the camera using a webbrowser on default IP address 169.254.1.101.
| |
− | | |
− | In the menu that appears, click '''System Settings''', and you will be asked to login:
| |
− | | |
− | Username: '''admin''' <br/>
| |
− | Password: '''1234'''
| |
− | | |
− | It is recommended to use a static IP address for the camera:
| |
− | | |
− | [[File:Axis 2.PNG|thumb|left|500px|Setting Static IP Address]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | From the Main Menu navigate to '''Video Stream''':
| |
− | | |
− | [[File:Axis 1.PNG|thumb|left|500px|Axis camera configuration]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | ==Display Compatibility==
| |
− | This table shows the camera specific settings that must be set depending on the receiver
| |
− | {| border="1"
| |
− | | align="center" style="background:#ffcb00;" width="200pt"|'''Receiving unit'''
| |
− | | align="center" style="background:#ffcb00;" width="90pt"|'''Resolution'''
| |
− | | align="center" style="background:#ffcb00;" width="90pt"|'''Frame Rate'''
| |
− | | align="center" style="background:#ffcb00;" width="90pt"|'''Compression'''
| |
− | | align="center" style="background:#ffcb00;" width="400pt" |'''Comments'''
| |
− | |-
| |
− | | [[IP_Desktop_Station_with_Video_Display_-_1408001635#Camera_settings|IP Video Desktop]] ||align="center" | 320x240 ||align="center" | Unlimited ||align="center" | 30 ||align="center" | ||
| |
− | |-
| |
− | | [[SNOM IP Phone]] ||align="center" | 320x240 ||align="center" | Unlimited ||align="center" | 30 ||align="center" | ||
| |
− | |-
| |
− | | [[PhonerLite SIP Client]] ||align="center" | 320x240 ||align="center" | Unlimited ||align="center" | 30 ||align="center" | ||
| |
− | |-
| |
− | | [[DIVUS Videophone]] ||align="center" | 320x240 ||align="center" | Unlimited ||align="center" | 30 ||align="center" | ||
| |
− | |-
| |
− | |}
| |
− | | |
− | These units have been tested and found to be not supported:
| |
− | * BRIA (CounterPath) SIP client
| |
− | * CPCAM viewer
| |
− | | |
− | ==Axis Factory Reset==
| |
− | After a factory default, the Axis camera will get its IP address from a '''DHCP''' server.<br>
| |
− | If there is no DHCP server on the network, it will get the IP address '''192.168.0.90'''.
| |
− | | |
− | To restore the factory settings, proceed as follows:
| |
− | :1. Disconnect the camera from the power supply and ethernet.
| |
− | :2. Remove the four screws securing the rear cover and remove it.
| |
− | :3. Keep the Control button pressed while you restore the power supply.
| |
− | :4. Hold down the button for about 15 seconds until the status LED is yellow flashing.
| |
− | :5. Release the Control Button. The process is complete when the status LEDs light up green.
| |
− | | |
− | [[File:Axis.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | ''If no DHCP server is active on your network the new default IP is '''192.168.0.90'''.''
| |
− | ''The new default user is '''root''' with password '''pass'''''
| |
− | | |
− | | |
− | | |
− | [[Category: Stations]] | |
− | [[Category: IP Stations]]
| |
− | [[Category: Vandal Resistant Stations]]
| |
− | [[Category: Video]]
| |