Difference between revisions of "ICX 1.3.3.X - Release Notes"
From Zenitel Wiki
(→General information) |
(→ICX 1.3.3.2) |
||
(19 intermediate revisions by the same user not shown) | |||
Line 20: | Line 20: | ||
=Software Upgrade information= | =Software Upgrade information= | ||
− | *ICX-500: [[ICX-500_software_upgrade|ICX- | + | *ICX-500/510: [[ICX-500_software_upgrade|ICX Gateway - software upgrade]] |
*ICX-Core: [[ICX-AlphaCom Core - Installation]] | *ICX-Core: [[ICX-AlphaCom Core - Installation]] | ||
− | + | =ICX 1.3.3.2= | |
− | =ICX 1. | ||
==Release info== | ==Release info== | ||
− | + | '''ICX Version:''' 1.3.3.2 <br> | |
− | '''ICX Version:''' 1. | + | '''Date:''' 29.10.2024 <br> |
− | '''Date:''' | ||
'''Status:''' General Availability <br> | '''Status:''' General Availability <br> | ||
==Bug fixes == | ==Bug fixes == | ||
− | === MTN- | + | === MTN-4356 Fixed an issue where temperature sensor reported errors=== |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | === MTN- | + | === MTN-4414 Fixed a problem with establishing a SIP trunk when using feature 83 on ICX-500 with Billing enabled.=== |
− | === MTN- | + | === MTN-4496 Now the kernel part of the nand memory will be explicitly cleaned before upgrading=== |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<br> | <br> | ||
==Security fixes and improvements== | ==Security fixes and improvements== | ||
− | ===MTN- | + | === MTN-4244 Added a new DEL_SVP command that can be used to delete stored messages. === |
− | + | Usage example: $DEL_SVP U10 U1 | |
− | + | *First parameter is the message group. | |
− | + | *Second parameter is the message index. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | ===MTN-4422 Removed device update page=== | |
− | === MTN- | ||
− | === MTN- | + | ===MTN-4532 Updated OpenSSH version and other relevant libraries=== |
− | |||
− | |||
− | |||
− | |||
− | |||
<br> | <br> | ||
− | = | + | ==Enhancements and Fixed Issues for ICX-Gateway used as Primary System Controller (PSC) in Exigo== |
− | = | + | === MTN-4428 Maximum 8 messages could be started in parallel=== |
− | + | Increase the number of maximum parallel wav player resources to 30 (this includes chimes) | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | ===MTN- | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | ===MTN- | + | ===MTN-4427 ICX-500 Log web page not working=== |
+ | Fixed log print web page session | ||
− | ===MTN- | + | ===MTN-4380 Increased gain for recall and gong in Exigo mode=== |
− | ===MTN- | + | ===MTN-4322 Modbus not working with ICX-500 as controller=== |
+ | Add and start modbus daemon on ICX core system | ||
<br> | <br> | ||
− | + | =ICX 1.3.3.0= | |
− | |||
− | |||
− | |||
− | =ICX 1. | ||
==Release info== | ==Release info== | ||
− | + | '''ICX Version:''' 1.3.3.0 <br> | |
− | '''ICX Version:''' 1. | + | '''Date:''' 21.02.2024 <br> |
− | '''Date:''' | ||
'''Status:''' General Availability <br> | '''Status:''' General Availability <br> | ||
==Bug fixes == | ==Bug fixes == | ||
− | ===MTN- | + | === MTN-4311 Updated ICX-5x0 hardware labels in web === |
− | + | The hardware version "ICX-510" is now correctly displayed in '''System Monitoring''' > '''Node Information''' in the ICX web interface | |
− | |||
<br> | <br> | ||
==Security fixes and improvements== | ==Security fixes and improvements== | ||
− | ===MTN- | + | === MTN-4365 Update OpenSSL version === |
− | + | ICX-Alphacom and ICX-Core are updated to OpenSSL 3.0. | |
− | ===MTN- | + | === MTN-4366 Updated web banner for ICX-AlphaCom=== |
+ | The banner of the web interface of the ICX-AlphaCom has been updated with the "Zenitel" logo and brand name | ||
<br> | <br> | ||
− | + | ==Enhancements and Fixed Issues for ICX-Gateway used as Primary System Controller (PSC) in Exigo== | |
− | == | + | === MTN-4272 ICX as PSC (Primary System Controller) a sweeping noise on recall could occur=== |
− | + | Removed occurrence of a sweeping noise when using recall function. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | === MTN- | ||
− | |||
− | |||
− | |||
− | |||
− | === MTN- | + | === MTN-4268 ENA2100-AC channel shutdown error message handling updated=== |
+ | When ENA2100-AC channel shutdown error has disappeared, error message can now be removed. | ||
− | === MTN- | + | === MTN-4267 ICX as PSC (Primary System Controller), message of missing PSC (PSC error) did not disappear after reconnecting=== |
− | + | After a LAN disconnection of ICX, message of missing PSC (PSC error) in ESC1 GUI and Amplifier Web kept message despite ICX reconnection and operating. Updated to avoid faulty messages. | |
− | === MTN- | + | === MTN-4248 Broadcasting of Live speech and Recall recordings appeared with different levels on output=== |
− | + | Adjusted audio levels of the two types of broadcasting to be outputted equally. | |
− | + | === MTN-4235 ICX as PSC (Primary System Controller) the FCDC3 were not reported missing after being disconnected second time and Device Report timing were faulty=== | |
− | + | FCDC3 reported missing is now working after second time being disconnected and Missing Device Report is generated in less than 15 seconds. | |
− | |||
− | == | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | = | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | ===MTN- | + | === MTN-4090 Line fault LED takes long time to indicate for a detected fault=== |
+ | Line fault LED now reacts immediately when fault is detected. | ||
<br> | <br> | ||
[[Category: Release notes]] | [[Category: Release notes]] |
Latest revision as of 10:49, 29 October 2024
Previous Release - ICX 1.2.3.X - Release Notes
This article provides the release notes for ICX-500, ICX-510 and ICX-Core software 1.3.3.x with incremental bug fix releases. This release notes describe new features, improvements and issues fixed after ICX 1.2.3.x.
Contents
- 1 General information
- 2 Software Upgrade information
- 3 ICX 1.3.3.2
- 4 ICX 1.3.3.0
- 4.1 Release info
- 4.2 Bug fixes
- 4.3 Security fixes and improvements
- 4.4 Enhancements and Fixed Issues for ICX-Gateway used as Primary System Controller (PSC) in Exigo
- 4.4.1 MTN-4272 ICX as PSC (Primary System Controller) a sweeping noise on recall could occur
- 4.4.2 MTN-4268 ENA2100-AC channel shutdown error message handling updated
- 4.4.3 MTN-4267 ICX as PSC (Primary System Controller), message of missing PSC (PSC error) did not disappear after reconnecting
- 4.4.4 MTN-4248 Broadcasting of Live speech and Recall recordings appeared with different levels on output
- 4.4.5 MTN-4235 ICX as PSC (Primary System Controller) the FCDC3 were not reported missing after being disconnected second time and Device Report timing were faulty
- 4.4.6 MTN-4090 Line fault LED takes long time to indicate for a detected fault
General information
VSF-ICX-500 is a firmware archive for the ICX-500 Intelligent Gateway platform.
- vsfx-1.3.3.x{-n}.swu - Used for standard in-field upgrades
- vsfx-prod-1.3.3.x{n}.img.zip - Used in-field recovery and major system upgrades (SD-Card update)
- vsfx-prod-1.3.3.x{n}.zip - Used in production upgrade only.
|
ICX-Core software is an "apt" installation package for Ubuntu 22.04.x LTS Server containing the same functional capabilities as the ICX-500 Intelligent Gateway platform.
- ICX-Core-01.00-jammy-1.3.3.X.apt.tar - Used for installation from the Ubuntu shell or from ICX-Web interface on already running ICX-Core systems.
Software Upgrade information
- ICX-500/510: ICX Gateway - software upgrade
- ICX-Core: ICX-AlphaCom Core - Installation
ICX 1.3.3.2
Release info
ICX Version: 1.3.3.2
Date: 29.10.2024
Status: General Availability
Bug fixes
MTN-4356 Fixed an issue where temperature sensor reported errors
MTN-4414 Fixed a problem with establishing a SIP trunk when using feature 83 on ICX-500 with Billing enabled.
MTN-4496 Now the kernel part of the nand memory will be explicitly cleaned before upgrading
Security fixes and improvements
MTN-4244 Added a new DEL_SVP command that can be used to delete stored messages.
Usage example: $DEL_SVP U10 U1
- First parameter is the message group.
- Second parameter is the message index.
MTN-4422 Removed device update page
MTN-4532 Updated OpenSSH version and other relevant libraries
Enhancements and Fixed Issues for ICX-Gateway used as Primary System Controller (PSC) in Exigo
MTN-4428 Maximum 8 messages could be started in parallel
Increase the number of maximum parallel wav player resources to 30 (this includes chimes)
MTN-4427 ICX-500 Log web page not working
Fixed log print web page session
MTN-4380 Increased gain for recall and gong in Exigo mode
MTN-4322 Modbus not working with ICX-500 as controller
Add and start modbus daemon on ICX core system
ICX 1.3.3.0
Release info
ICX Version: 1.3.3.0
Date: 21.02.2024
Status: General Availability
Bug fixes
MTN-4311 Updated ICX-5x0 hardware labels in web
The hardware version "ICX-510" is now correctly displayed in System Monitoring > Node Information in the ICX web interface
Security fixes and improvements
MTN-4365 Update OpenSSL version
ICX-Alphacom and ICX-Core are updated to OpenSSL 3.0.
MTN-4366 Updated web banner for ICX-AlphaCom
The banner of the web interface of the ICX-AlphaCom has been updated with the "Zenitel" logo and brand name
Enhancements and Fixed Issues for ICX-Gateway used as Primary System Controller (PSC) in Exigo
MTN-4272 ICX as PSC (Primary System Controller) a sweeping noise on recall could occur
Removed occurrence of a sweeping noise when using recall function.
MTN-4268 ENA2100-AC channel shutdown error message handling updated
When ENA2100-AC channel shutdown error has disappeared, error message can now be removed.
MTN-4267 ICX as PSC (Primary System Controller), message of missing PSC (PSC error) did not disappear after reconnecting
After a LAN disconnection of ICX, message of missing PSC (PSC error) in ESC1 GUI and Amplifier Web kept message despite ICX reconnection and operating. Updated to avoid faulty messages.
MTN-4248 Broadcasting of Live speech and Recall recordings appeared with different levels on output
Adjusted audio levels of the two types of broadcasting to be outputted equally.
MTN-4235 ICX as PSC (Primary System Controller) the FCDC3 were not reported missing after being disconnected second time and Device Report timing were faulty
FCDC3 reported missing is now working after second time being disconnected and Missing Device Report is generated in less than 15 seconds.
MTN-4090 Line fault LED takes long time to indicate for a detected fault
Line fault LED now reacts immediately when fault is detected.