Actions

ICX 1.3.3.X - Release Notes

From Zenitel Wiki

Previous Release - ICX 1.2.3.X - Release Notes

This article provides the release notes for ICX-500, ICX-510 and ICX-Core software 1.3.3.x with incremental bug fix releases. This release notes describe new features, improvements and issues fixed after ICX 1.2.3.x.

Contents

General information

VSF-ICX-500 is a firmware archive for the ICX-500 Intelligent Gateway platform.

  • vsfx-1.3.3.x{-n}.swu - Used for standard in-field upgrades
  • vsfx-prod-1.3.3.x{n}.img.zip - Used in-field recovery and major system upgrades (SD-Card update)
  • vsfx-prod-1.3.3.x{n}.zip - Used in production upgrade only.
Note icon
  • The first 4 numbers in version directly links to the the ICX-Core version.
  • The last optional "-n" number is added for vsfx build with only platform changes form the first ICX-Core build for vsfx.''


ICX-Core software is an "apt" installation package for Ubuntu 22.04.x LTS Server containing the same functional capabilities as the ICX-500 Intelligent Gateway platform.

  • ICX-Core-01.00-jammy-1.3.3.X.apt.tar - Used for installation from the Ubuntu shell or from ICX-Web interface on already running ICX-Core systems.

Software Upgrade information

ICX 1.3.3.2

Release info

ICX Version: 1.3.3.2
Date: 29.10.2024
Status: General Availability

Bug fixes

MTN-4356 Fixed an issue where temperature sensor reported errors

MTN-4414 Fixed a problem with establishing a SIP trunk when using feature 83 on ICX-500 with Billing enabled.

MTN-4496 Now the kernel part of the nand memory will be explicitly cleaned before upgrading


Security fixes and improvements

MTN-4244 Added a new DEL_SVP command that can be used to delete stored messages.

Usage example: $DEL_SVP U10 U1

  • First parameter is the message group.
  • Second parameter is the message index.

MTN-4422 Removed device update page

MTN-4532 Updated OpenSSH version and other relevant libraries


Enhancements and Fixed Issues for ICX-Gateway used as Primary System Controller (PSC) in Exigo

MTN-4428 Maximum 8 messages could be started in parallel

Increase the number of maximum parallel wav player resources to 30 (this includes chimes)

MTN-4427 ICX-500 Log web page not working

Fixed log print web page session

MTN-4380 Increased gain for recall and gong in Exigo mode

MTN-4322 Modbus not working with ICX-500 as controller

Add and start modbus daemon on ICX core system


ICX 1.3.3.0

Release info

ICX Version: 1.3.3.0
Date: 21.02.2024
Status: General Availability

Bug fixes

MTN-4311 Updated ICX-5x0 hardware labels in web

The hardware version "ICX-510" is now correctly displayed in System Monitoring > Node Information in the ICX web interface


Security fixes and improvements

MTN-4365 Update OpenSSL version

ICX-Alphacom and ICX-Core are updated to OpenSSL 3.0.

MTN-4366 Updated web banner for ICX-AlphaCom

The banner of the web interface of the ICX-AlphaCom has been updated with the "Zenitel" logo and brand name


Enhancements and Fixed Issues for ICX-Gateway used as Primary System Controller (PSC) in Exigo

MTN-4272 ICX as PSC (Primary System Controller) a sweeping noise on recall could occur

Removed occurrence of a sweeping noise when using recall function.

MTN-4268 ENA2100-AC channel shutdown error message handling updated

When ENA2100-AC channel shutdown error has disappeared, error message can now be removed.

MTN-4267 ICX as PSC (Primary System Controller), message of missing PSC (PSC error) did not disappear after reconnecting

After a LAN disconnection of ICX, message of missing PSC (PSC error) in ESC1 GUI and Amplifier Web kept message despite ICX reconnection and operating. Updated to avoid faulty messages.

MTN-4248 Broadcasting of Live speech and Recall recordings appeared with different levels on output

Adjusted audio levels of the two types of broadcasting to be outputted equally.

MTN-4235 ICX as PSC (Primary System Controller) the FCDC3 were not reported missing after being disconnected second time and Device Report timing were faulty

FCDC3 reported missing is now working after second time being disconnected and Missing Device Report is generated in less than 15 seconds.

MTN-4090 Line fault LED takes long time to indicate for a detected fault

Line fault LED now reacts immediately when fault is detected.