Line 7: | Line 7: | ||
------------ | ------------ | ||
− | '''Event 1 - Move the substation to COS 2, start a timer, and disconnect the master station | + | '''Event 1''' - Move the substation to COS 2, start a timer, and disconnect the master station. |
{| | {| | ||
|- | |- | ||
|width="100pt"|'''Event Owner''': | |width="100pt"|'''Event Owner''': | ||
− | |width=" | + | |width="400pt"|The Master Station |
|- | |- | ||
− | |'''Event type''': || 25 – Event trigger with parameter | + | |'''Event type''': || [[Event Trigger with parameter (Event Type)|25 – Event trigger with parameter]] |
|- | |- | ||
|'''Subevent''': || 0 | |'''Subevent''': || 0 | ||
Line 21: | Line 21: | ||
|'''When related to''': || All | |'''When related to''': || All | ||
|- | |- | ||
− | |'''Action''': || $SSC L%2.dir U2 | + | |'''Action''': || [[SET_STATION_COS|$SSC L%2.dir U2]] |
|- | |- | ||
− | | || $ST L%2.dir W9000 L9999 | + | | || [[SET_TIMER|$ST L%2.dir W9000 L9999]] |
|- | |- | ||
− | | || $DISCON_ST L%1.dir U2 | + | | || [[DISCON_ST|$DISCON_ST L%1.dir U2]] |
|- | |- | ||
− | | || $PROG L%2.dir LV | + | | || [[PROGRAM|$PROG L%2.dir LV]] |
|- | |- | ||
Revision as of 13:31, 18 November 2008
This article describes how a master station can disable substations from making calls for a periode of time.
Solution
In the programming example below the master station dials 9535 + substation directory number to disable calls from that substation for 15 minutes.
Directory number 9535 is by default a two-step event trigger, feature 95/0. When 9535 + Substation is dialled, an event type 25 is triggered and the action string $SSC L%2.dir U2 moves the substation to COS 2. COS 2 is by default empty, which will prevent calls to be initiated. The command $DISCON_ST L%1.dir U2 will disconnect the master station with a success tone after having entered the substation number. A 15 minute timer is started by the command $ST L%2.dir W9000 L9999. When the timer expires it will trigger event type 21, and the command $SSC L%1.dir U1 will move the station back to COS 1, and calls can again be made.
Event 1 - Move the substation to COS 2, start a timer, and disconnect the master station.
Event Owner: | The Master Station |
Event type: | 25 – Event trigger with parameter |
Subevent: | 0 |
When change to: | ON |
When related to: | All |
Action: | $SSC L%2.dir U2 |
$ST L%2.dir W9000 L9999 | |
$DISCON_ST L%1.dir U2 | |
$PROG L%2.dir LV |
Event 2 - Move the substation back to COS 1:
Event Owner: | Stations w/UDP Id: 8 (All stations) |
Event type: | 21 – Event timer |
When change to: | ON |
When related to: | Directory number: 9999 |
Action: | $SSC L%1.dir U1 |