Actions

Anti-nuisance control (Event Handler): Difference between revisions

From Zenitel Wiki

No edit summary
No edit summary
Line 34: Line 34:


---------------
---------------
'''Event 2 - Move the substation back to COS 1:'''
'''Event 2''' - Move the substation back to COS 1.
{|  
{|  
|-
|-
|width="100pt"|'''Event Owner''':
|width="100pt"|'''Event Owner''':
|width="300pt"|Stations w/UDP Id: 8 (All stations)
|width="400pt"|Stations w/UDP, Id: 8 (All stations)
|-
|-
|'''Event type''': || 21 – Event timer
|'''Event type''': || [[Event Timeout|21 – Event timer]]
|-
|-
|'''When change to''': || ON
|'''When change to''': || ON
|-
|-
|'''When related to''': || Directory number: 9999
|'''When related to''': || Directory number, Id: 9999
|-
|-
|'''Action''': || $SSC L%1.dir U1
|'''Action''': || [[SET_STATION_COS|$SSC L%1.dir U1]]
|-
|-
|}
|}

Revision as of 13:35, 18 November 2008

This article describes how a master station can disable substations from making calls for a periode of time.

Solution

In the programming example below the master station dials 9535 + substation directory number to disable calls from that substation for 15 minutes.

Directory number 9535 is by default a two-step event trigger, feature 95/0. When 9535 + Substation is dialled, an event type 25 is triggered and the action string $SSC L%2.dir U2 moves the substation to COS 2. COS 2 is by default empty, which will prevent calls to be initiated. The command $DISCON_ST L%1.dir U2 will disconnect the master station with a success tone after having entered the substation number. A 15 minute timer is started by the command $ST L%2.dir W9000 L9999. When the timer expires it will trigger event type 21, and the command $SSC L%1.dir U1 will move the station back to COS 1, and calls can again be made.


Event 1 - Move the substation to COS 2, start a timer, and disconnect the master station.

Event Owner: The Master Station
Event type: 25 – Event trigger with parameter
Subevent: 0
When change to: ON
When related to: All
Action: $SSC L%2.dir U2
  $ST L%2.dir W9000 L9999
  $DISCON_ST L%1.dir U2
  $PROG L%2.dir LV



Event 2 - Move the substation back to COS 1.

Event Owner: Stations w/UDP, Id: 8 (All stations)
Event type: 21 – Event timer
When change to: ON
When related to: Directory number, Id: 9999
Action: $SSC L%1.dir U1