Difference between revisions of "Turbine 4.11 - Release notes"
From Zenitel Wiki
(→Release info) |
(→SNOW-703 Trap support for CI on ENA2060) |
||
(25 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
− | + | Previous Release - [[Turbine 4.9 - Release notes]] | |
− | |||
+ | Next Release - [[Turbine 5.0 - Release notes]] | ||
+ | |||
+ | This document provides the release notes for VSF-Turbine 4.11 with incremental bug fix releases. The release notes for VSF-Turbine 4.11 describe new features, improvements and issues fixed after VSF-Turbine 4.9. | ||
+ | |||
+ | ==Release info== | ||
'''Name:''' VSF-Turbine <br> | '''Name:''' VSF-Turbine <br> | ||
'''Description:''' VSF-Turbine is a firmware archive for all [[:Category:Stations#Turbine_stations|Turbine Family Intercom stations]] including devices: | '''Description:''' VSF-Turbine is a firmware archive for all [[:Category:Stations#Turbine_stations|Turbine Family Intercom stations]] including devices: | ||
− | '''TCIS-x''', '''TKIS-2''', '''TCIV-x''', '''TMIS-x''', '''TFIE-x''', '''TKIE-x''', '''TFIX-x''', '''ECPIR-3P''', '''ENA- | + | '''TCIS-x''', '''TKIS-2''', '''TCIV-x''', '''TMIS-x''', '''TFIE-x''', '''TKIE-x''', '''TFIX-x''', '''ECPIR-3P''', '''IP-LCM unit''', '''ENA-2060DC''', '''Exigo IP speakers''' and '''Exigo Network Amplifiers''' (AlphaCom mode only). <br> |
'''Version:''' The firmware is delivered in two different ZIP archives: | '''Version:''' The firmware is delivered in two different ZIP archives: | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | = VSF-TURBINE 4.11.2.5 = | + | *'''vsft-4.11.3.x''' - Used for standard in-field upgrades |
− | ==New Features - Turbine Intercom | + | *'''vsft-prod-4.11.3.x''' - Used in production- and recovery upgrades. <br> |
− | === SNOW-496 IP Station support for RFC3891 SIP "Replaces" Header === | + | |
+ | '''Version:''' 4.11.3.1 <br> | ||
+ | '''Date:''' November 2019 <br> | ||
+ | '''Status:'''General Availability <br> | ||
+ | |||
+ | =VSF-TURBINE 4.11.3.1= | ||
+ | ==Bugfixes and Improvements - Turbine Intercom== | ||
+ | ===MTN-2634 Factory reset on ENA2060 did not work=== | ||
+ | Now factory reset on ENA2060 works using input button 1. | ||
+ | |||
+ | ===MTN-2389 SIP invite now contains RTP map listing each individual audio codec.=== | ||
+ | This will fix interoperability with some SBC's. | ||
+ | |||
+ | ===MTN-2464 Industrial stations have factory reset over frontboard/gpio working correctly again=== | ||
+ | PTT can now be used again to factory reset. Also, resetting via frontboard is more reliable. | ||
+ | |||
+ | ===MTN-2461 TKIE-3 handset PTT input did not work=== | ||
+ | TKIE-3 PTT handling is now fixed. | ||
+ | |||
+ | ===MTN-2537 In SIP mode the station could crash on short messages=== | ||
+ | In SIP mode messages shorter than 4 bytes could crash the station. This has been fixed. | ||
+ | |||
+ | ===MTN-2605 ENA2060 Continuous monitoring measurement updated first time after 1 hour=== | ||
+ | ENA2060 will now update continuous line monitoring measurements 5-15 seconds after successful calibration and then once per hour | ||
+ | |||
+ | ===MTN-2533 Not possible to save changes on Video and Advanced video pages with HTTPS=== | ||
+ | Pressing Save on Video and Advanced video pages if HTTPS was used did not properly save changes. This has now been fixed. | ||
+ | |||
+ | ===MTN-2594 DAK Call Setup priority not stored in station backup=== | ||
+ | Call Setup priority was not preserved during upgrade for inputs. This is now fixed. | ||
+ | |||
+ | ===MTN-2433 IP-LCM external relays shown on Webcall form=== | ||
+ | IP-LCM external relays are now properly shown on Webcall form | ||
+ | |||
+ | ===MTN-2447 IP-LCM in Pulse mode has wrong number of relays in Advanced Output Handler=== | ||
+ | The number of relays in the advanced output handler configuration is now corrected. | ||
+ | |||
+ | ===MTN-2536 Syslog TCP port=== | ||
+ | Syslog suggests a default TCP port, but you had to manually enter it in order to get syslog working. Now you don't need to enter the port anymore. | ||
+ | |||
+ | ===MTN-2456 Reading IP address on ENA2060 did not work=== | ||
+ | Reading IP address on ENA2060 using an input now works. | ||
+ | |||
+ | ===MTN-2507 Support for updated camera board kernel on TCIV units=== | ||
+ | TCIV now supports updated camera board kernel which is applied in production, it's not necessary to update camera board kernel on already produced TCIV stations. TCIV stations with camera board kernel version 3716, can only be used with firmware version 4.11.3.1, 5.1.3.0 and newer. It's not possible to downgrade these stations to older firmware versions. | ||
+ | |||
+ | ===MTN-2481 TFTP provisioning would sometimes look for wrong filename if SIP domain has not been configured=== | ||
+ | TFTP provisioning would sometimes look for wrong file with IPv6 address instead of IPv4 address if the primary SIP domain had not been configured. This has been fixed. | ||
+ | |||
+ | ===MTN-2312 Turbine devices not booting completely=== | ||
+ | If a Turbine device has gotten an IP address from a DHCP server, and then reboots without contact to the DHCP server, the Turbine will go into cyclic reboot until it gets in contact with DHCP server again. This has now been fixed. | ||
+ | |||
+ | ==Security fixes and improvements== | ||
+ | ===MTN-2496 HTTP call and relay API is disabled by default.=== | ||
+ | User can enable HTTP API via web call page. This also affect users using Virtual I/O script that leverages this API, they will have to enable it on receiving station. | ||
+ | |||
+ | <br> | ||
+ | |||
+ | ==Known Issues== | ||
+ | ===MTN-2363 Factory reset does not delete uploaded Script=== | ||
+ | All uploaded scripts should also be removed on Factory reset | ||
+ | |||
+ | ===MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream=== | ||
+ | H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream. | ||
+ | |||
+ | ===MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR=== | ||
+ | RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream | ||
+ | |||
+ | ===MTN-2360 Client side forwarding does not work in SIP mode=== | ||
+ | Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding. | ||
+ | |||
+ | ===MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer=== | ||
+ | Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert | ||
+ | |||
+ | ===MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.=== | ||
+ | When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call. | ||
+ | |||
+ | ===MTN-2356 SNMP not working properly on TCIV under high CPU load=== | ||
+ | SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues. | ||
+ | |||
+ | ===MTN-2339 Group call chime is not played on 3rd party SIP stations=== | ||
+ | Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address. | ||
+ | |||
+ | ===MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working=== | ||
+ | On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) is not working. Other keys are functional. | ||
+ | |||
+ | ===MTN-1073 Group call fails if system previously configured with ZAP=== | ||
+ | If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations. | ||
+ | |||
+ | <br> | ||
+ | |||
+ | =VSF-TURBINE 4.11.3.0= | ||
+ | ==New Features - Turbine Intercom== | ||
+ | ===SNOW-496 IP Station support for RFC3891 SIP "Replaces" Header=== | ||
The IP Station (Turbine and INCA) now support Reinvite / INVITE with replaces, which is quite common function used in SIP environments. The needed function is described in RFC3891. | The IP Station (Turbine and INCA) now support Reinvite / INVITE with replaces, which is quite common function used in SIP environments. The needed function is described in RFC3891. | ||
− | === SNOW-818 Keep-alive for improved VoIP NAT traversal === | + | ===SNOW-818 Keep-alive for improved VoIP NAT traversal=== |
NAT keep-alive is a feature that sends very tiny UDP data packets from a VoIP client to the router to show that the port is still in use. Turbine and INCA are now sending keep-alives every 25 seconds if have enabled "NAT Keep Alive" under Call Settings. | NAT keep-alive is a feature that sends very tiny UDP data packets from a VoIP client to the router to show that the port is still in use. Turbine and INCA are now sending keep-alives every 25 seconds if have enabled "NAT Keep Alive" under Call Settings. | ||
− | === SNOW-330 IP Multicast audio support for Pulse Intercom=== | + | ===SNOW-330 IP Multicast audio support for Pulse Intercom=== |
Turbine and INCA IP intercom stations now support IP multicast audio when configured in Pulse mode. Previously, only SIP mode was supported. Up to 10 multicast IP addresses can be configured. | Turbine and INCA IP intercom stations now support IP multicast audio when configured in Pulse mode. Previously, only SIP mode was supported. Up to 10 multicast IP addresses can be configured. | ||
− | === SNOW-192 Chinese font on Turbine OLED display=== | + | ===SNOW-192 Chinese font on Turbine OLED display=== |
Turbine now supports Chinese language characters with new font package. New vsf-chinese-font_x.x.x.x_armel.ipk package is made, which can be installed on the turbine (download can be found on our Wiki) | Turbine now supports Chinese language characters with new font package. New vsf-chinese-font_x.x.x.x_armel.ipk package is made, which can be installed on the turbine (download can be found on our Wiki) | ||
− | === SNOW-871 TCIV-5 firmware support=== | + | ===SNOW-871 TCIV-5 firmware support=== |
Turbine firmware now supports a new TCIV-5 Turbine IP station model. | Turbine firmware now supports a new TCIV-5 Turbine IP station model. | ||
− | === SNOW-1165 Image quality improvements for TCIV=== | + | ===SNOW-1165 Image quality improvements for TCIV=== |
Low-level optimizations were made for AEWB engine (Automatic Exposure and White Balancing) resulting in following image quality improvements: Better low-light performance, Better overall color accuracy and contrast, Smoother dynamic dark-light transitions. | Low-level optimizations were made for AEWB engine (Automatic Exposure and White Balancing) resulting in following image quality improvements: Better low-light performance, Better overall color accuracy and contrast, Smoother dynamic dark-light transitions. | ||
− | === SNOW-83 ONVIF Profile-S support on TCIV=== | + | ===SNOW-83 ONVIF Profile-S support on TCIV=== |
TCIV now fully supports and is compliant with ONVIF Profile-S specification. As a standard in the industry, Profile-S can be used to integrate with a variety of VMS and NVR products. | TCIV now fully supports and is compliant with ONVIF Profile-S specification. As a standard in the industry, Profile-S can be used to integrate with a variety of VMS and NVR products. | ||
− | === SNOW-1166 RTSP support for TCIV video stream === | + | ===SNOW-1166 RTSP support for TCIV video stream=== |
RTSP is an industry standard network control protocol for establishing and controlling media streams. TCIV now comes with a full support for RTSP video streams. | RTSP is an industry standard network control protocol for establishing and controlling media streams. TCIV now comes with a full support for RTSP video streams. | ||
− | === SNOW-1169 Dual stream functionality on TCIV=== | + | ===SNOW-1169 Dual stream functionality on TCIV=== |
TCIV now supports dual-streaming functionality where two independent video streams can be separately initiated and controlled. Streams can be configured with different protocols (SIP, RTSP, ONVIF, HTTP), different codec and resolution, and are both lip-synced if audio and video is being used - using the industry standard RTCP protocol. | TCIV now supports dual-streaming functionality where two independent video streams can be separately initiated and controlled. Streams can be configured with different protocols (SIP, RTSP, ONVIF, HTTP), different codec and resolution, and are both lip-synced if audio and video is being used - using the industry standard RTCP protocol. | ||
− | === SNOW-1167 RTSP audio stream support for all Turbine devices=== | + | ===SNOW-1167 RTSP audio stream support for all Turbine devices=== |
RTSP is an industry standard network control protocol for establishing and controlling media streams. All Turbine intercom devices and kits now fully support RTSP for outgoing audio streams. | RTSP is an industry standard network control protocol for establishing and controlling media streams. All Turbine intercom devices and kits now fully support RTSP for outgoing audio streams. | ||
− | === SNOW-1168 Lip-sync of Audio and Video on TCIV=== | + | ===SNOW-1168 Lip-sync of Audio and Video on TCIV=== |
Audio and Video streams initiated using ONVIF or RTSP protocols are lip-synced for both streaming and recording, implemented using the industry standard RTP Control Protocol (RTCP). | Audio and Video streams initiated using ONVIF or RTSP protocols are lip-synced for both streaming and recording, implemented using the industry standard RTP Control Protocol (RTCP). | ||
− | ==New Features - | + | ===SNOW-1013 Pulse systems can now be integrated with Exigo system=== |
− | === SNOW- | + | Using the SIP interface on Exigo systems allows for integration both ways to pulse systems. Exigo 1.4.3.0 or newer required. |
− | + | ||
+ | ===SNOW-2301 Added "Stop Message" as an audio message option=== | ||
+ | "Stop Message" can be used to stop other audio messages. It has the same options as other audio messages. | ||
+ | |||
+ | <br> | ||
+ | |||
+ | ==New Features - Exigo Amplifiers== | ||
+ | ===SNOW-1014 Exigo Amplifiers now support distributed automatic volume controllers=== | ||
+ | Distributed Automatic Volume Controllers are TKIS-2 kits which measures background noise in an area and can adjust the volume settings for an amplifier or IP speaker so that the audio is audiable above the noise | ||
+ | |||
+ | ===SNOW-1012 ENA2100-AC is now supported in Alphacom systems=== | ||
+ | |||
+ | *Advanced line monitoring and Lets supported | ||
+ | *Hardware audio bypass supported | ||
+ | *2 control outputs with 200mA@24Vdc each | ||
+ | *2 control inputs | ||
+ | *Supported in Exigo mode and Alphacom systems | ||
+ | |||
+ | <br> | ||
+ | |||
+ | ==Bugfixes and Improvements - Turbine Intercom== | ||
+ | ===MTN-2257 Audio Input Source option removed for Compact Turbine stations=== | ||
+ | Audio Input Source configuration option was removed for Compact Turbine stations because they don't have a physical Line In connector, so this configuration option did not have any effect on them. | ||
+ | |||
+ | ===MTN-1527 IP Multicast Audio audible interruptions=== | ||
+ | It was possible to hear audible effects during IP Multicast audio playback, and with a relatively high interval rate. This is now fixed. | ||
− | + | ===MTN-1930 TFIE-6 does not display AlphaCom status-messages in Idle=== | |
− | === MTN- | + | AlphaCom status messages did not work correctly on TFIE-6. For example, it was not possible to see if a TFIE-6 is forwarded(71,72) or marked absent(77x). |
− | |||
− | === MTN- | + | ===MTN-2258 ECPIR-3P M-key does not perform key-release action=== |
− | + | ECPIR-3P M-key would not allow to exit the call if DAK In call was configured to exit on the M-key release | |
− | === MTN-1498 Group call fails after Pulse Server reboots and takes ~ 5 min to work again=== | + | ===MTN-1974 Sound detection on Turbine is not triggered properly=== |
+ | Sound Detection is never triggered on, but "DAK off" is reported. Fixed | ||
+ | |||
+ | ===MTN-1498 Group call fails after Pulse Server reboots and takes ~ 5 min to work again=== | ||
The registration information is now properly stored in the Pulse server and Group call shall work immediately after server restart. | The registration information is now properly stored in the Pulse server and Group call shall work immediately after server restart. | ||
− | === MTN- | + | ===MTN-2314 Using overlap dialing started ringing audio message for each digit pressed=== |
− | + | When dialing on keyboard using overlap dialing, the ringing audio message would get executed for each digit pressed instead of only when call actually was ringing. | |
+ | |||
+ | ===MTN-2313 Audio message executes twice when ringing=== | ||
+ | If you configure an audio message to play during ringing, it will start playing, then shortly after restart again. This is now fixed. | ||
+ | |||
+ | ===MTN-2259 Configured PTT\M-Key action when using EMMAR-1H=== | ||
+ | When using EMMAR-1H the DAK call configuration for M/PPT key couldn't be initialized if the In call button configuration for the M/PTT was End call | ||
+ | |||
+ | ===MTN-2342 Issue with using "&" character in display text on TCIV-6 and TCIS-6=== | ||
+ | Now it is possible to use the "&" symbol as part of the display text on TCIV-6 and TCIS-6. | ||
− | === MTN-2122 In HD Audio mode the station would report missing RTP=== | + | ===MTN-2122 In HD Audio mode the station would report missing RTP=== |
In HD Audio mode the station would incorrectly report missing RTP when it is meant to only send audio. This has been fixed. | In HD Audio mode the station would incorrectly report missing RTP when it is meant to only send audio. This has been fixed. | ||
− | === MTN-2086 AEC Performance Improvements - Reduced Echo Artifacts=== | + | ===MTN-2086 AEC Performance Improvements - Reduced Echo Artifacts=== |
By tuning the Acoustic Echo Cancellation algorithm options we have reduced the level of produced Echo artifacts on Turbine stations at high-level speaker outputs. | By tuning the Acoustic Echo Cancellation algorithm options we have reduced the level of produced Echo artifacts on Turbine stations at high-level speaker outputs. | ||
− | === MTN- | + | ===MTN-2274 Using ZAP to set volume did not work=== |
− | + | ZAP can now be used to set volume for amplifiers and Turbine | |
+ | |||
+ | ===MTN-2341 Custom frontboard configuration now supports up to 11 DAK keys, from previous 8.=== | ||
+ | All 11 physical DAK keys can now be configured when custom frontobard is used. | ||
− | === MTN-2085 Far-End signal limiter on Turbine=== | + | ===MTN-2085 Far-End signal limiter on Turbine=== |
Far-End signal Limiter filter is designed to avoid powerful Far-End signal bringing the station to PoE shutdown as well as try to avoid Far-End Signal clipping and distortions. | Far-End signal Limiter filter is designed to avoid powerful Far-End signal bringing the station to PoE shutdown as well as try to avoid Far-End Signal clipping and distortions. | ||
− | === MTN-2019 TCIV displays incorrect default image resolution for MJPEG HTTP=== | + | ===MTN-2019 TCIV displays incorrect default image resolution for MJPEG HTTP=== |
− | When opening HTTP MJPEG video stream in a web browser (http://IP-Address:8090) the video is displayed in smaller resolution then a defined default of 480p. | + | When opening HTTP MJPEG video stream in a web browser (http://IP-Address:8090) the video is displayed in smaller resolution then a defined default of 480p., this is now fixed by properly applying configured resolution. |
− | === SNOW-313 RTSP support for TCIV H.264 stream (AlphaCom)=== | + | ===SNOW-313 RTSP support for TCIV H.264 stream (AlphaCom)=== |
Added RTSP H.264 support on ITSV-1 to initiate video stream from TCIV in AlphaCom mode | Added RTSP H.264 support on ITSV-1 to initiate video stream from TCIV in AlphaCom mode | ||
− | === SNOW- | + | ===SNOW-887 Video setup mode "Cisco" removed=== |
− | + | Due to the fixes in video stream FPS stability the "Cisco" video setup mode was made obsolete and therefore removed from StationWeb options | |
− | + | <br> | |
− | |||
− | |||
− | |||
− | === | + | ==Bugfixes and Improvements - Exigo Amplifiers== |
− | + | ===MTN-2246 Suspend monitoring not always working for ENA in AlphaCom=== | |
+ | Certain directory number configurations could previously stop suspend monitoring from working when using Exigo network amplifiers (ENA) in AlphaCom mode. This has been fixed. | ||
+ | |||
+ | |||
+ | <br> | ||
+ | |||
+ | ==Security fixes and improvements== | ||
+ | ===MTN-2366 Basic MJPEG HTTP authentication should be enabled by default=== | ||
+ | Now the option to Enable basic HTTP authentication for HTTP MJPEG is enabled by default. | ||
+ | |||
+ | ===MTN-2102 Password on Pulse server Directory settings shown as plain text=== | ||
+ | Password on Pulse server Directory settings page was displayed as plain text. Now it is displayed as standard HTML password field. | ||
− | + | <br> | |
− | |||
− | |||
− | ==Known Issues == | + | ==Known Issues== |
− | === | + | ===MTN-2363 Factory reset does not delete uploaded Script=== |
All uploaded scripts should also be removed on Factory reset | All uploaded scripts should also be removed on Factory reset | ||
− | === | + | ===MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream=== |
− | + | H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream. | |
− | === | + | ===MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR=== |
− | + | RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream | |
− | === | + | ===MTN-2360 Client side forwarding does not work in SIP mode=== |
− | + | Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding. | |
− | === MTN- | + | ===MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer=== |
− | + | Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert | |
− | === MTN- | + | ===MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.=== |
− | + | When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call. | |
− | ===MTN- | + | ===MTN-2356 SNMP not working properly on TCIV under high CPU load=== |
− | + | SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues. | |
+ | ===MTN-2339 Group call chime is not played on 3rd party SIP stations=== | ||
+ | Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address. | ||
+ | ===MTN-2312 Turbine devices not booting completely=== | ||
+ | If a Turbine device has gotten a IP address from a DHCP server, and then reboots without contact to the DHCP server, the Turbine will go into cyclic reboot until it gets in contact with DHCP server again. | ||
− | = VSF-TURBINE 4.10.3.0 = | + | Workaround: Make sure a DHCP server is available or factory reset with static IP address. |
− | ==New Features - Turbine Intercom | + | |
− | === SNOW-421 Advanced GPO configuration for Pulse and SIP=== | + | ===MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working=== |
+ | On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) is not working. Other keys are functional. | ||
+ | |||
+ | ===MTN-1073 Group call fails if system previously configured with ZAP=== | ||
+ | If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations. | ||
+ | |||
+ | <br> | ||
+ | |||
+ | =VSF-TURBINE 4.10.3.0= | ||
+ | ==New Features - Turbine Intercom== | ||
+ | ===SNOW-421 Advanced GPO configuration for Pulse and SIP=== | ||
Turbine now has option to use standard Relay configuration or use the new and more Advanced GPO (output) configuration. | Turbine now has option to use standard Relay configuration or use the new and more Advanced GPO (output) configuration. | ||
− | === SNOW-1011 IP-LCM support in SIP, Pulse and Alphacom=== | + | ===SNOW-1011 IP-LCM support in SIP, Pulse and Alphacom=== |
IP-LCM is now supported in SIP, Pulse and Alphacom systems. This device has: | IP-LCM is now supported in SIP, Pulse and Alphacom systems. This device has: | ||
+ | |||
*8 robust high power relays | *8 robust high power relays | ||
*8 robust inputs | *8 robust inputs | ||
Line 135: | Line 287: | ||
==New Features - Exigo Amplifiers== | ==New Features - Exigo Amplifiers== | ||
− | === SNOW-595 Exigo Network Amplifiers can now fall back to routing line input in cases where servers are unavailable === | + | ===SNOW-595 Exigo Network Amplifiers can now fall back to routing line input in cases where servers are unavailable=== |
<br> | <br> | ||
− | == Bugfixes and Improvements - Turbine Intercom == | + | ==Bugfixes and Improvements - Turbine Intercom== |
− | === MTN-1709 Fault led on all Turbine industrial stations, Turbine EX stations and Exigo Access panels can now be configured with custom behavior in Alphacom=== | + | ===MTN-1709 Fault led on all Turbine industrial stations, Turbine EX stations and Exigo Access panels can now be configured with custom behavior in Alphacom=== |
− | === SNOW-319 TKIE-3 support in Turbine firmware=== | + | ===SNOW-319 TKIE-3 support in Turbine firmware=== |
TKIE-3 is now supported in Turbine firmware | TKIE-3 is now supported in Turbine firmware | ||
− | === SNOW-321 Implement Distributed AVC in SIP Mode=== | + | ===SNOW-321 Implement Distributed AVC in SIP Mode=== |
All "Turbine Devices" can be AVC Source (Ambient audio listener) or AVC destination. | All "Turbine Devices" can be AVC Source (Ambient audio listener) or AVC destination. | ||
− | === SNOW-328 Adjust volume using SIP OPTIONS with X-Header=== | + | ===SNOW-328 Adjust volume using SIP OPTIONS with X-Header=== |
It is now possible to adjust volume using SIP OPTIONS with x-header by adding x-volume-level-override. The function will override the configured station volume | It is now possible to adjust volume using SIP OPTIONS with x-header by adding x-volume-level-override. The function will override the configured station volume | ||
− | === SNOW-552 Syslog support === | + | ===SNOW-552 Syslog support=== |
Turbine now supports logging to the syslog server. Up to 3 syslog server destinations are supported | Turbine now supports logging to the syslog server. Up to 3 syslog server destinations are supported | ||
− | === SNOW-592 AGC for line/mic in=== | + | ===SNOW-592 AGC for line/mic in=== |
Automatic Gain Control now works for Line/Mic in depending on configured input selection | Automatic Gain Control now works for Line/Mic in depending on configured input selection | ||
− | === SNOW-1173 New call functions in SIP=== | + | ===SNOW-1173 New call functions in SIP=== |
It is now possible to put call on hold or defer a call using DAK configuration | It is now possible to put call on hold or defer a call using DAK configuration | ||
− | == Bugfixes and Improvements - Exigo Amplifiers == | + | ==Bugfixes and Improvements - Exigo Amplifiers== |
− | === SNOW-340 ENA2060 Line Monitoring improved=== | + | ===SNOW-340 ENA2060 Line Monitoring improved=== |
Changes made to line monitoring of ENA2060 to make it more robust | Changes made to line monitoring of ENA2060 to make it more robust | ||
− | === SNOW-183 SNMP Traps on Exigo amplifiers=== | + | ===SNOW-183 SNMP Traps on Exigo amplifiers=== |
Device status and fault messages can be sent as SNMP Traps. | Device status and fault messages can be sent as SNMP Traps. | ||
− | === SNOW-562 ENA-2060 does not report disabled channel=== | + | ===SNOW-562 ENA-2060 does not report disabled channel=== |
ENA2060 will now correctly report channel state when one of the channels are disabled manually | ENA2060 will now correctly report channel state when one of the channels are disabled manually | ||
− | === SNOW-111 Detailed channel state in SNMP MIB=== | + | ===SNOW-111 Detailed channel state in SNMP MIB=== |
Detailed information about the actual state of the audio channel is now included in the SNMP MIB. | Detailed information about the actual state of the audio channel is now included in the SNMP MIB. | ||
− | === SNOW-703 Trap support for CI on ENA2060=== | + | ===SNOW-703 Trap support for CI on ENA2060=== |
Control inputs on ENA2060 can now generate a trap for SNMP with a custom message. | Control inputs on ENA2060 can now generate a trap for SNMP with a custom message. | ||
− | |||
− | |||
[[Category: Release notes]] | [[Category: Release notes]] |
Latest revision as of 09:17, 23 June 2022
Previous Release - Turbine 4.9 - Release notes
Next Release - Turbine 5.0 - Release notes
This document provides the release notes for VSF-Turbine 4.11 with incremental bug fix releases. The release notes for VSF-Turbine 4.11 describe new features, improvements and issues fixed after VSF-Turbine 4.9.
Contents
- 1 Release info
- 2 VSF-TURBINE 4.11.3.1
- 2.1 Bugfixes and Improvements - Turbine Intercom
- 2.1.1 MTN-2634 Factory reset on ENA2060 did not work
- 2.1.2 MTN-2389 SIP invite now contains RTP map listing each individual audio codec.
- 2.1.3 MTN-2464 Industrial stations have factory reset over frontboard/gpio working correctly again
- 2.1.4 MTN-2461 TKIE-3 handset PTT input did not work
- 2.1.5 MTN-2537 In SIP mode the station could crash on short messages
- 2.1.6 MTN-2605 ENA2060 Continuous monitoring measurement updated first time after 1 hour
- 2.1.7 MTN-2533 Not possible to save changes on Video and Advanced video pages with HTTPS
- 2.1.8 MTN-2594 DAK Call Setup priority not stored in station backup
- 2.1.9 MTN-2433 IP-LCM external relays shown on Webcall form
- 2.1.10 MTN-2447 IP-LCM in Pulse mode has wrong number of relays in Advanced Output Handler
- 2.1.11 MTN-2536 Syslog TCP port
- 2.1.12 MTN-2456 Reading IP address on ENA2060 did not work
- 2.1.13 MTN-2507 Support for updated camera board kernel on TCIV units
- 2.1.14 MTN-2481 TFTP provisioning would sometimes look for wrong filename if SIP domain has not been configured
- 2.1.15 MTN-2312 Turbine devices not booting completely
- 2.2 Security fixes and improvements
- 2.3 Known Issues
- 2.3.1 MTN-2363 Factory reset does not delete uploaded Script
- 2.3.2 MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream
- 2.3.3 MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR
- 2.3.4 MTN-2360 Client side forwarding does not work in SIP mode
- 2.3.5 MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer
- 2.3.6 MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.
- 2.3.7 MTN-2356 SNMP not working properly on TCIV under high CPU load
- 2.3.8 MTN-2339 Group call chime is not played on 3rd party SIP stations
- 2.3.9 MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working
- 2.3.10 MTN-1073 Group call fails if system previously configured with ZAP
- 2.1 Bugfixes and Improvements - Turbine Intercom
- 3 VSF-TURBINE 4.11.3.0
- 3.1 New Features - Turbine Intercom
- 3.1.1 SNOW-496 IP Station support for RFC3891 SIP "Replaces" Header
- 3.1.2 SNOW-818 Keep-alive for improved VoIP NAT traversal
- 3.1.3 SNOW-330 IP Multicast audio support for Pulse Intercom
- 3.1.4 SNOW-192 Chinese font on Turbine OLED display
- 3.1.5 SNOW-871 TCIV-5 firmware support
- 3.1.6 SNOW-1165 Image quality improvements for TCIV
- 3.1.7 SNOW-83 ONVIF Profile-S support on TCIV
- 3.1.8 SNOW-1166 RTSP support for TCIV video stream
- 3.1.9 SNOW-1169 Dual stream functionality on TCIV
- 3.1.10 SNOW-1167 RTSP audio stream support for all Turbine devices
- 3.1.11 SNOW-1168 Lip-sync of Audio and Video on TCIV
- 3.1.12 SNOW-1013 Pulse systems can now be integrated with Exigo system
- 3.1.13 SNOW-2301 Added "Stop Message" as an audio message option
- 3.2 New Features - Exigo Amplifiers
- 3.3 Bugfixes and Improvements - Turbine Intercom
- 3.3.1 MTN-2257 Audio Input Source option removed for Compact Turbine stations
- 3.3.2 MTN-1527 IP Multicast Audio audible interruptions
- 3.3.3 MTN-1930 TFIE-6 does not display AlphaCom status-messages in Idle
- 3.3.4 MTN-2258 ECPIR-3P M-key does not perform key-release action
- 3.3.5 MTN-1974 Sound detection on Turbine is not triggered properly
- 3.3.6 MTN-1498 Group call fails after Pulse Server reboots and takes ~ 5 min to work again
- 3.3.7 MTN-2314 Using overlap dialing started ringing audio message for each digit pressed
- 3.3.8 MTN-2313 Audio message executes twice when ringing
- 3.3.9 MTN-2259 Configured PTT\M-Key action when using EMMAR-1H
- 3.3.10 MTN-2342 Issue with using "&" character in display text on TCIV-6 and TCIS-6
- 3.3.11 MTN-2122 In HD Audio mode the station would report missing RTP
- 3.3.12 MTN-2086 AEC Performance Improvements - Reduced Echo Artifacts
- 3.3.13 MTN-2274 Using ZAP to set volume did not work
- 3.3.14 MTN-2341 Custom frontboard configuration now supports up to 11 DAK keys, from previous 8.
- 3.3.15 MTN-2085 Far-End signal limiter on Turbine
- 3.3.16 MTN-2019 TCIV displays incorrect default image resolution for MJPEG HTTP
- 3.3.17 SNOW-313 RTSP support for TCIV H.264 stream (AlphaCom)
- 3.3.18 SNOW-887 Video setup mode "Cisco" removed
- 3.4 Bugfixes and Improvements - Exigo Amplifiers
- 3.5 Security fixes and improvements
- 3.6 Known Issues
- 3.6.1 MTN-2363 Factory reset does not delete uploaded Script
- 3.6.2 MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream
- 3.6.3 MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR
- 3.6.4 MTN-2360 Client side forwarding does not work in SIP mode
- 3.6.5 MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer
- 3.6.6 MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.
- 3.6.7 MTN-2356 SNMP not working properly on TCIV under high CPU load
- 3.6.8 MTN-2339 Group call chime is not played on 3rd party SIP stations
- 3.6.9 MTN-2312 Turbine devices not booting completely
- 3.6.10 MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working
- 3.6.11 MTN-1073 Group call fails if system previously configured with ZAP
- 3.1 New Features - Turbine Intercom
- 4 VSF-TURBINE 4.10.3.0
- 4.1 New Features - Turbine Intercom
- 4.2 New Features - Exigo Amplifiers
- 4.3 Bugfixes and Improvements - Turbine Intercom
- 4.3.1 MTN-1709 Fault led on all Turbine industrial stations, Turbine EX stations and Exigo Access panels can now be configured with custom behavior in Alphacom
- 4.3.2 SNOW-319 TKIE-3 support in Turbine firmware
- 4.3.3 SNOW-321 Implement Distributed AVC in SIP Mode
- 4.3.4 SNOW-328 Adjust volume using SIP OPTIONS with X-Header
- 4.3.5 SNOW-552 Syslog support
- 4.3.6 SNOW-592 AGC for line/mic in
- 4.3.7 SNOW-1173 New call functions in SIP
- 4.4 Bugfixes and Improvements - Exigo Amplifiers
Release info
Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices:
TCIS-x, TKIS-2, TCIV-x, TMIS-x, TFIE-x, TKIE-x, TFIX-x, ECPIR-3P, IP-LCM unit, ENA-2060DC, Exigo IP speakers and Exigo Network Amplifiers (AlphaCom mode only).
Version: The firmware is delivered in two different ZIP archives:
- vsft-4.11.3.x - Used for standard in-field upgrades
- vsft-prod-4.11.3.x - Used in production- and recovery upgrades.
Version: 4.11.3.1
Date: November 2019
Status:General Availability
VSF-TURBINE 4.11.3.1
Bugfixes and Improvements - Turbine Intercom
MTN-2634 Factory reset on ENA2060 did not work
Now factory reset on ENA2060 works using input button 1.
MTN-2389 SIP invite now contains RTP map listing each individual audio codec.
This will fix interoperability with some SBC's.
MTN-2464 Industrial stations have factory reset over frontboard/gpio working correctly again
PTT can now be used again to factory reset. Also, resetting via frontboard is more reliable.
MTN-2461 TKIE-3 handset PTT input did not work
TKIE-3 PTT handling is now fixed.
MTN-2537 In SIP mode the station could crash on short messages
In SIP mode messages shorter than 4 bytes could crash the station. This has been fixed.
MTN-2605 ENA2060 Continuous monitoring measurement updated first time after 1 hour
ENA2060 will now update continuous line monitoring measurements 5-15 seconds after successful calibration and then once per hour
MTN-2533 Not possible to save changes on Video and Advanced video pages with HTTPS
Pressing Save on Video and Advanced video pages if HTTPS was used did not properly save changes. This has now been fixed.
MTN-2594 DAK Call Setup priority not stored in station backup
Call Setup priority was not preserved during upgrade for inputs. This is now fixed.
MTN-2433 IP-LCM external relays shown on Webcall form
IP-LCM external relays are now properly shown on Webcall form
MTN-2447 IP-LCM in Pulse mode has wrong number of relays in Advanced Output Handler
The number of relays in the advanced output handler configuration is now corrected.
MTN-2536 Syslog TCP port
Syslog suggests a default TCP port, but you had to manually enter it in order to get syslog working. Now you don't need to enter the port anymore.
MTN-2456 Reading IP address on ENA2060 did not work
Reading IP address on ENA2060 using an input now works.
MTN-2507 Support for updated camera board kernel on TCIV units
TCIV now supports updated camera board kernel which is applied in production, it's not necessary to update camera board kernel on already produced TCIV stations. TCIV stations with camera board kernel version 3716, can only be used with firmware version 4.11.3.1, 5.1.3.0 and newer. It's not possible to downgrade these stations to older firmware versions.
MTN-2481 TFTP provisioning would sometimes look for wrong filename if SIP domain has not been configured
TFTP provisioning would sometimes look for wrong file with IPv6 address instead of IPv4 address if the primary SIP domain had not been configured. This has been fixed.
MTN-2312 Turbine devices not booting completely
If a Turbine device has gotten an IP address from a DHCP server, and then reboots without contact to the DHCP server, the Turbine will go into cyclic reboot until it gets in contact with DHCP server again. This has now been fixed.
Security fixes and improvements
MTN-2496 HTTP call and relay API is disabled by default.
User can enable HTTP API via web call page. This also affect users using Virtual I/O script that leverages this API, they will have to enable it on receiving station.
Known Issues
MTN-2363 Factory reset does not delete uploaded Script
All uploaded scripts should also be removed on Factory reset
MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
MTN-2360 Client side forwarding does not work in SIP mode
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert
MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
MTN-2356 SNMP not working properly on TCIV under high CPU load
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
MTN-2339 Group call chime is not played on 3rd party SIP stations
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.
MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working
On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) is not working. Other keys are functional.
MTN-1073 Group call fails if system previously configured with ZAP
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.
VSF-TURBINE 4.11.3.0
New Features - Turbine Intercom
SNOW-496 IP Station support for RFC3891 SIP "Replaces" Header
The IP Station (Turbine and INCA) now support Reinvite / INVITE with replaces, which is quite common function used in SIP environments. The needed function is described in RFC3891.
SNOW-818 Keep-alive for improved VoIP NAT traversal
NAT keep-alive is a feature that sends very tiny UDP data packets from a VoIP client to the router to show that the port is still in use. Turbine and INCA are now sending keep-alives every 25 seconds if have enabled "NAT Keep Alive" under Call Settings.
SNOW-330 IP Multicast audio support for Pulse Intercom
Turbine and INCA IP intercom stations now support IP multicast audio when configured in Pulse mode. Previously, only SIP mode was supported. Up to 10 multicast IP addresses can be configured.
SNOW-192 Chinese font on Turbine OLED display
Turbine now supports Chinese language characters with new font package. New vsf-chinese-font_x.x.x.x_armel.ipk package is made, which can be installed on the turbine (download can be found on our Wiki)
SNOW-871 TCIV-5 firmware support
Turbine firmware now supports a new TCIV-5 Turbine IP station model.
SNOW-1165 Image quality improvements for TCIV
Low-level optimizations were made for AEWB engine (Automatic Exposure and White Balancing) resulting in following image quality improvements: Better low-light performance, Better overall color accuracy and contrast, Smoother dynamic dark-light transitions.
SNOW-83 ONVIF Profile-S support on TCIV
TCIV now fully supports and is compliant with ONVIF Profile-S specification. As a standard in the industry, Profile-S can be used to integrate with a variety of VMS and NVR products.
SNOW-1166 RTSP support for TCIV video stream
RTSP is an industry standard network control protocol for establishing and controlling media streams. TCIV now comes with a full support for RTSP video streams.
SNOW-1169 Dual stream functionality on TCIV
TCIV now supports dual-streaming functionality where two independent video streams can be separately initiated and controlled. Streams can be configured with different protocols (SIP, RTSP, ONVIF, HTTP), different codec and resolution, and are both lip-synced if audio and video is being used - using the industry standard RTCP protocol.
SNOW-1167 RTSP audio stream support for all Turbine devices
RTSP is an industry standard network control protocol for establishing and controlling media streams. All Turbine intercom devices and kits now fully support RTSP for outgoing audio streams.
SNOW-1168 Lip-sync of Audio and Video on TCIV
Audio and Video streams initiated using ONVIF or RTSP protocols are lip-synced for both streaming and recording, implemented using the industry standard RTP Control Protocol (RTCP).
SNOW-1013 Pulse systems can now be integrated with Exigo system
Using the SIP interface on Exigo systems allows for integration both ways to pulse systems. Exigo 1.4.3.0 or newer required.
SNOW-2301 Added "Stop Message" as an audio message option
"Stop Message" can be used to stop other audio messages. It has the same options as other audio messages.
New Features - Exigo Amplifiers
SNOW-1014 Exigo Amplifiers now support distributed automatic volume controllers
Distributed Automatic Volume Controllers are TKIS-2 kits which measures background noise in an area and can adjust the volume settings for an amplifier or IP speaker so that the audio is audiable above the noise
SNOW-1012 ENA2100-AC is now supported in Alphacom systems
- Advanced line monitoring and Lets supported
- Hardware audio bypass supported
- 2 control outputs with 200mA@24Vdc each
- 2 control inputs
- Supported in Exigo mode and Alphacom systems
Bugfixes and Improvements - Turbine Intercom
MTN-2257 Audio Input Source option removed for Compact Turbine stations
Audio Input Source configuration option was removed for Compact Turbine stations because they don't have a physical Line In connector, so this configuration option did not have any effect on them.
MTN-1527 IP Multicast Audio audible interruptions
It was possible to hear audible effects during IP Multicast audio playback, and with a relatively high interval rate. This is now fixed.
MTN-1930 TFIE-6 does not display AlphaCom status-messages in Idle
AlphaCom status messages did not work correctly on TFIE-6. For example, it was not possible to see if a TFIE-6 is forwarded(71,72) or marked absent(77x).
MTN-2258 ECPIR-3P M-key does not perform key-release action
ECPIR-3P M-key would not allow to exit the call if DAK In call was configured to exit on the M-key release
MTN-1974 Sound detection on Turbine is not triggered properly
Sound Detection is never triggered on, but "DAK off" is reported. Fixed
MTN-1498 Group call fails after Pulse Server reboots and takes ~ 5 min to work again
The registration information is now properly stored in the Pulse server and Group call shall work immediately after server restart.
MTN-2314 Using overlap dialing started ringing audio message for each digit pressed
When dialing on keyboard using overlap dialing, the ringing audio message would get executed for each digit pressed instead of only when call actually was ringing.
MTN-2313 Audio message executes twice when ringing
If you configure an audio message to play during ringing, it will start playing, then shortly after restart again. This is now fixed.
MTN-2259 Configured PTT\M-Key action when using EMMAR-1H
When using EMMAR-1H the DAK call configuration for M/PPT key couldn't be initialized if the In call button configuration for the M/PTT was End call
MTN-2342 Issue with using "&" character in display text on TCIV-6 and TCIS-6
Now it is possible to use the "&" symbol as part of the display text on TCIV-6 and TCIS-6.
MTN-2122 In HD Audio mode the station would report missing RTP
In HD Audio mode the station would incorrectly report missing RTP when it is meant to only send audio. This has been fixed.
MTN-2086 AEC Performance Improvements - Reduced Echo Artifacts
By tuning the Acoustic Echo Cancellation algorithm options we have reduced the level of produced Echo artifacts on Turbine stations at high-level speaker outputs.
MTN-2274 Using ZAP to set volume did not work
ZAP can now be used to set volume for amplifiers and Turbine
MTN-2341 Custom frontboard configuration now supports up to 11 DAK keys, from previous 8.
All 11 physical DAK keys can now be configured when custom frontobard is used.
MTN-2085 Far-End signal limiter on Turbine
Far-End signal Limiter filter is designed to avoid powerful Far-End signal bringing the station to PoE shutdown as well as try to avoid Far-End Signal clipping and distortions.
MTN-2019 TCIV displays incorrect default image resolution for MJPEG HTTP
When opening HTTP MJPEG video stream in a web browser (http://IP-Address:8090) the video is displayed in smaller resolution then a defined default of 480p., this is now fixed by properly applying configured resolution.
SNOW-313 RTSP support for TCIV H.264 stream (AlphaCom)
Added RTSP H.264 support on ITSV-1 to initiate video stream from TCIV in AlphaCom mode
SNOW-887 Video setup mode "Cisco" removed
Due to the fixes in video stream FPS stability the "Cisco" video setup mode was made obsolete and therefore removed from StationWeb options
Bugfixes and Improvements - Exigo Amplifiers
MTN-2246 Suspend monitoring not always working for ENA in AlphaCom
Certain directory number configurations could previously stop suspend monitoring from working when using Exigo network amplifiers (ENA) in AlphaCom mode. This has been fixed.
Security fixes and improvements
MTN-2366 Basic MJPEG HTTP authentication should be enabled by default
Now the option to Enable basic HTTP authentication for HTTP MJPEG is enabled by default.
MTN-2102 Password on Pulse server Directory settings shown as plain text
Password on Pulse server Directory settings page was displayed as plain text. Now it is displayed as standard HTML password field.
Known Issues
MTN-2363 Factory reset does not delete uploaded Script
All uploaded scripts should also be removed on Factory reset
MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
MTN-2360 Client side forwarding does not work in SIP mode
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert
MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
MTN-2356 SNMP not working properly on TCIV under high CPU load
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
MTN-2339 Group call chime is not played on 3rd party SIP stations
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.
MTN-2312 Turbine devices not booting completely
If a Turbine device has gotten a IP address from a DHCP server, and then reboots without contact to the DHCP server, the Turbine will go into cyclic reboot until it gets in contact with DHCP server again.
Workaround: Make sure a DHCP server is available or factory reset with static IP address.
MTN-2074 TKIE-3 keyboard matrix Vol Up/Down not working
On the TKIE-3 in AlphaCom mode with keyboard matrix the Volume UP (J9-5 and J9-7) and Volume DOWN (J9-5 and J9-6) is not working. Other keys are functional.
MTN-1073 Group call fails if system previously configured with ZAP
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.
VSF-TURBINE 4.10.3.0
New Features - Turbine Intercom
SNOW-421 Advanced GPO configuration for Pulse and SIP
Turbine now has option to use standard Relay configuration or use the new and more Advanced GPO (output) configuration.
SNOW-1011 IP-LCM support in SIP, Pulse and Alphacom
IP-LCM is now supported in SIP, Pulse and Alphacom systems. This device has:
- 8 robust high power relays
- 8 robust inputs
- Powered via the TKIS-2 kit with PoE, PoE inject or external power supply
- All connections and features from the TKIS-2 kit available
New Features - Exigo Amplifiers
Bugfixes and Improvements - Turbine Intercom
MTN-1709 Fault led on all Turbine industrial stations, Turbine EX stations and Exigo Access panels can now be configured with custom behavior in Alphacom
SNOW-319 TKIE-3 support in Turbine firmware
TKIE-3 is now supported in Turbine firmware
SNOW-321 Implement Distributed AVC in SIP Mode
All "Turbine Devices" can be AVC Source (Ambient audio listener) or AVC destination.
SNOW-328 Adjust volume using SIP OPTIONS with X-Header
It is now possible to adjust volume using SIP OPTIONS with x-header by adding x-volume-level-override. The function will override the configured station volume
SNOW-552 Syslog support
Turbine now supports logging to the syslog server. Up to 3 syslog server destinations are supported
SNOW-592 AGC for line/mic in
Automatic Gain Control now works for Line/Mic in depending on configured input selection
SNOW-1173 New call functions in SIP
It is now possible to put call on hold or defer a call using DAK configuration
Bugfixes and Improvements - Exigo Amplifiers
SNOW-340 ENA2060 Line Monitoring improved
Changes made to line monitoring of ENA2060 to make it more robust
SNOW-183 SNMP Traps on Exigo amplifiers
Device status and fault messages can be sent as SNMP Traps.
SNOW-562 ENA-2060 does not report disabled channel
ENA2060 will now correctly report channel state when one of the channels are disabled manually
SNOW-111 Detailed channel state in SNMP MIB
Detailed information about the actual state of the audio channel is now included in the SNMP MIB.
SNOW-703 Trap support for CI on ENA2060
Control inputs on ENA2060 can now generate a trap for SNMP with a custom message.