The ZDD-1 must be powered by PoE+ or PoE++. | The ZDD-1 must be powered by PoE+ or PoE++. | ||
{{note|<br> | {{note|<br> | ||
* ''PoE+ (or PoE++) must be used. '''Regular PoE | * ''PoE+ (or PoE++) must be used. '''Regular PoE does not provide sufficient power''' for the ZDD-1 unit. As soon as audio is being played the unit might consume more power than what is available from PoE (12.95W), and the device is likely to reboot.''<br> | ||
* ''If the loudspeaker volume is set to maximum, the ZDD-1 might require more power than PoE+ can deliver (25.5W). In this case PoE++ is required''. <br> | * ''If the loudspeaker volume is set to maximum, the ZDD-1 might require more power than PoE+ can deliver (25.5W). In this case PoE++ is required''. <br> | ||
* ''Power by an external power supply in not supported}} | * ''Power by an external power supply in not supported}} | ||
| Line 19: | Line 19: | ||
* [[SIP Intercom - Web Interface|SIP mode]] | * [[SIP Intercom - Web Interface|SIP mode]] | ||
* Zenitel Connect Pro (ZCP) | * Zenitel Connect Pro (ZCP) | ||
* [[Configuration of the ZDD-1 (used with ICX-AlphaCom)|ZDD-1 used with ICX-AlphaCom]] | |||
{{note| | {{note| | ||
* ''To use this device with '''[[:Category:Zenitel Connect Pro|Zenitel Connect Pro]]''' it must be factory defaulted. The device configuration is done from the Zenitel Connect Pro server.''<br> | * ''To use this device with '''[[:Category:Zenitel Connect Pro|Zenitel Connect Pro]]''' it must be factory defaulted. The device configuration is done from the Zenitel Connect Pro server.''<br> | ||
* ''To use this device with '''[[:Category:ICX-AlphaCom Platform|ICX AlphaCom]]''' it must be in SIP mode, and a SIP Station license is required}} | * ''To use this device with '''[[:Category:ICX-AlphaCom Platform|ICX AlphaCom]]''' it must be in SIP mode, and a [[Licenses_for_ICX-500_and_ICX-AlphaCom_Core|SIP Station license ILS-SIP]] is required in the ICX-AlphaCom}} | ||
== GUI and Display Configuration == | |||
* [[Configuration of the ZDD-1 (Edge/SIP)]] | * [[Configuration of the ZDD-1 (Edge/SIP)|Configuration when used in Edge or SIP mode]] | ||
* [[Configuration of the ZDD-1 (ZCP)|Configuration | * [[Configuration of the ZDD-1 (ZCP)|Configuration when used with Zenitel Connect Pro (ZCP)]] | ||
* [[ | |||
== Audio and Video Configuration == | |||
* [[Audio Settings (Devices)|Audio Settings]] | |||
* [[Video Settings]] | |||
<!--* [[RTSP and ONVIF Settings (TCIV Station)|RTSP and ONVIF Settings]]--> | |||
==Restore Factory Defaults and Software Upgrade== | ==Restore Factory Defaults and Software Upgrade== | ||
| Line 34: | Line 39: | ||
*[[IMT - Discover & Upgrade|Upgrade using the IMT tool]] | *[[IMT - Discover & Upgrade|Upgrade using the IMT tool]] | ||
*[[Automatic Software Upgrade|Automatic Software Upgrade (SIP mode only)]] | *[[Automatic Software Upgrade|Automatic Software Upgrade (SIP mode only)]] | ||
*[[:Category: | *[[:Category:Zenitel Display Series - Release notes|Software Release Notes]] | ||
==Connectors, Indicators and Dimensions== | ==Connectors, Indicators and Dimensions== | ||
*[[ZDD-1 Connections|Board Connections]] | *[[ZDD-1 Connections|Board Connections]] | ||
*[[ZDD-1 Dimensions|Dimensions]] | *[[ZDD-1 Dimensions|Dimensions]] | ||
== Accessories == | |||
The [[TA-35|TA-35 Onwall backbox]] is mandatory for onwall mounting of the ZDD-1. | |||
== Mounting and Installation == | == Mounting and Installation == | ||
* [https://www.zenitel.com/sites/default/files/2025-03/A100K12255%20ZDD-1%20Mounting%20and%20Installation%20Manual%20v1.3.pdf Mounting and Installation Manual] | |||
* | |||
==Software Requirements== | ==Software Requirements== | ||
| Line 49: | Line 57: | ||
==Related Information== | ==Related Information== | ||
* | * [https://www.zenitel.com/product/zdd-1-video-intercom-display Additional Documentation on Zenitel.com] | ||
[[Category: Turbine]] | [[Category: Turbine]] | ||
Latest revision as of 12:46, 4 April 2025
The Zenitel Display Door intercom ZDD-1 is featuring a sleek low-profile design and touch screen. The intercom is built with Zenitel's durable construction, providing flexible mounting options that make it suitable for a variety of spaces and environments. The touch screen features a user friendly interface with an intuitive menu, and the placement of microphones and speakers ensures clear communication.
Power
The ZDD-1 must be powered by PoE+ or PoE++.
Getting started
Configuration
The ZDD-1 can operate in different modes, depending on what kind of server it should register to. Choose one of the links below according to what mode you need to configure.
General configuration:
- Edge mode
- SIP mode
- Zenitel Connect Pro (ZCP)
- ZDD-1 used with ICX-AlphaCom
|
GUI and Display Configuration
Audio and Video Configuration
Restore Factory Defaults and Software Upgrade
- Restore Factory Defaults
- Upgrade via the station web interface
- Upgrade using the IMT tool
- Automatic Software Upgrade (SIP mode only)
- Software Release Notes
Connectors, Indicators and Dimensions
Accessories
The TA-35 Onwall backbox is mandatory for onwall mounting of the ZDD-1.
Mounting and Installation
Software Requirements
This station is fully supported as from firmware version 9.1.3.0.