Line 23: | Line 23: | ||
* The six inputs on the TKIS-2 module are triggered by connecting the Input to GND via a closed contact. | * The six inputs on the TKIS-2 module are triggered by connecting the Input to GND via a closed contact. | ||
* Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See [[IP-LCM Connections]] for details. | * Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See [[IP-LCM Connections]] for details. | ||
− | |||
Input actions are configured in the [[Event Handler]] of the AlphaCom server. Inputs will trigger the event [[Station Input or Station DAK key (Event Type)|30 - Station Input or Station DAK key]], and the Sub-Event is used to identify which input is being triggered. | Input actions are configured in the [[Event Handler]] of the AlphaCom server. Inputs will trigger the event [[Station Input or Station DAK key (Event Type)|30 - Station Input or Station DAK key]], and the Sub-Event is used to identify which input is being triggered. | ||
− | + | In [[AlphaPro]], go to [[Users & Stations (AlphaPro)|Users & Stations]], and select the IP-LCM from the list box. Select '''Events''', and '''Insert''' a new event with the following properties: | |
== Outputs == | == Outputs == | ||
* The 8 relays must be mapped to RCO pins 17-24, see [[RCO - Remote Control Output]] | * The 8 relays must be mapped to RCO pins 17-24, see [[RCO - Remote Control Output]] |
Revision as of 14:11, 17 April 2019
This article describes how to configure the IP-LCM Module when used with an AlphaCom server.
Basic configuration
The IP-LCM requires an IP Station License in the AlphaCom server in order to get registered.
To make a IP-LCM Module operational there are essentially four parameters to set in the web interface of the module. Log In to the module, go to Station Main > Main Settings, and:
- Set Station Mode = "Use AlphaCom"
- Configure the IP Settings (IP address) of the IP-LCM
- Enter the AlphaCom IP-address
- Enter Station Directory Number
The Directory Number must be defined in the AlphaCom Server using the AlphaPro configuration tool.
Inputs
The IP-LCM module has in total 14 inputs:
- 6 inputs on the The TKIS-2 module itself
- 8 inputs on the IP-LCM board
- The six inputs on the TKIS-2 module are triggered by connecting the Input to GND via a closed contact.
- Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See IP-LCM Connections for details.
Input actions are configured in the Event Handler of the AlphaCom server. Inputs will trigger the event 30 - Station Input or Station DAK key, and the Sub-Event is used to identify which input is being triggered.
In AlphaPro, go to Users & Stations, and select the IP-LCM from the list box. Select Events, and Insert a new event with the following properties:
Outputs
- The 8 relays must be mapped to RCO pins 17-24, see RCO - Remote Control Output