Actions

Difference between revisions of "Anti-nuisance control (Event Handler)"

From Zenitel Wiki

Line 29: Line 29:
 
|   || [[PROGRAM|$PROG L%2.dir LV]]
 
|   || [[PROGRAM|$PROG L%2.dir LV]]
 
|-
 
|-
 
 
|}
 
|}
 
  
 
---------------
 
---------------
Line 49: Line 47:
 
|-
 
|-
 
|}
 
|}
 +
 
------------------
 
------------------
  
  
 
[[Category:Applications]]
 
[[Category:Applications]]

Revision as of 14:18, 18 November 2008

This article describes how a master station can disable substations from making calls for a periode of time.

Solution

In the programming example below the master station dials 9535 + substation directory number to disable calls from that substation for 15 minutes.

Directory number 9535 is by default a two-step event trigger, feature 95/0. When 9535 + Substation is dialled, an event type 25 is triggered and the action string $SSC L%2.dir U2 moves the substation to COS 2. COS 2 is by default empty, which will prevent calls to be initiated. The command $DISCON_ST L%1.dir U2 will disconnect the master station with a success tone after having entered the substation number. A 15 minute timer is started by the command $ST L%2.dir W9000 L9999. When the timer expires it will trigger event type 21, and the command $SSC L%1.dir U1 will move the station back to COS 1, and calls can again be made.


Event 1 - Move the substation to COS 2, start a timer, and disconnect the master station.

Event Owner: The Master Station
Event type: 25 – Event trigger with parameter
Subevent: 0
When change to: ON
When related to: All
Action: $SSC L%2.dir U2
  $ST L%2.dir W9000 L9999
  $DISCON_ST L%1.dir U2
  $PROG L%2.dir LV

Event 2 - Move the substation back to COS 1.

Event Owner: Stations w/UDP, Id: 8 (All stations)
Event type: 21 – Event timer
When change to: ON
When related to: Directory number, Id: 9999
Action: $SSC L%1.dir U1