Line 21: | Line 21: | ||
* Eth0 has IP address 169.254.1.5 | * Eth0 has IP address 169.254.1.5 | ||
* Eth1 has no IP address by default | * Eth1 has no IP address by default | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==Software Upgrade== | ==Software Upgrade== | ||
Line 116: | Line 93: | ||
XE1 does not support any RCO's in the server itself. If remote control outputs are required, please use [[TKIS-2|TKIS-2 kit]] or [[IP-ARIO]]. | XE1 does not support any RCO's in the server itself. If remote control outputs are required, please use [[TKIS-2|TKIS-2 kit]] or [[IP-ARIO]]. | ||
+ | ==Load Factory Defaults (coldstart)== | ||
+ | Performing a '''cold start''' of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0. | ||
+ | |||
+ | [[File:AMC-IP ColdStartButton.png|thumb|left|250px|The "Cold Start" button on AMC-IP board]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | ===Factory Default procedure=== | ||
+ | * Remove the front cover of the AlphaCom XE1 | ||
+ | * Press and hold the "Cold Start" button on the AMC-IP card | ||
+ | * Power up the AlphaCom XE1 while keeping the "Cold Start" button pressed | ||
+ | * Keep the button pressed for minmum 3 seconds after power on, then release the button | ||
+ | |||
+ | === Factory Default of intercom settings only, keeping the IP setting === | ||
+ | * Remove the front cover of the AlphaCom XE1 | ||
+ | * Power up the AlphaCom XE1 | ||
+ | * 10 seconds after power on, press and hold the "Cold Start" button on the AMC-IP card | ||
+ | * Keep the "Cold Start" button pressed until the status LED of the AMC-IP is blinking green. | ||
+ | |||
+ | ===Other methods of factory default=== | ||
+ | A factory default can also be achieved in other ways: | ||
+ | * '''From [[AlphaWeb]]''': System Maintenance -> System Recovery -> Load Factory Defaults | ||
+ | * '''From [[AlphaPro]]:''' Upload a default AlphaPro database to the exchange | ||
==Additional Documentation on Zenitel.com == | ==Additional Documentation on Zenitel.com == |
Revision as of 14:21, 16 November 2017
Contents
Highlights
- Made to provide critical communication in any environment
- Supports 552 IP stations
- Environmental friendly and energy saving - max. 4 W
- SIM card based software configuration and disaster recovery
- Fully compatible with any AlphaCom system
Connections
Power
The AlphaCom XE1 is powered from 90-240VAC via a 5VDC power adapter. The power adapter comes with the XE1 server.
Network
The XE1 server has two RJ-45 ethernet ports for IP communication. Ethernet port 0 (Eth 0) is by default configured as a Management port, allowing connection to the embedded web server (AlphaWeb) and connection of the PC configuration tool AlphaPro. Default IP addresses:
- Eth0 has IP address 169.254.1.5
- Eth1 has no IP address by default
Software Upgrade
Software upgrade is performed via the web interface of the AlphaCom XE1 server, see AMC-IP software upgrade
Serial Ports
The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
Serial Port 0
9-Pin D-sub (RS232 Only)
- No additional settings necessary
Serial Port 1
RJ45 (RS232/422/485)
- Additional settings:
- RS232:
- Switch 8 on S601 on the AMC-IP board must be set to OFF.
- RS422/485:
- Switch 8 on S601 on the AMC-IP board must be set to ON.
- Take off the top lid to reach the jumpers inside, and set them to the correct position.
- - RS485: Both jumpers in position 2-3 (default)
- - RS422: Both jumpers in position 1-2
Remote Control Inputs (RCI)
Connections
There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors
Configuration
In AlphaPro there is an RCI table, where the physical address of the input is entered, along with the desired actions. The physical address is given as device + pin-number.
The RCI table supports up to 140 inputs.
- For internal RCIs in the AlphaCom XE1, the device address is 65, and the pin number is 1-2.
- Internal pin number 8 is the temperature alarm (not used in XE1).
- Mappings for the internal RCI's are autoloaded. Mappings for external RCI's (Slave modules, RIO's or IPARIO) must be manually programmed.
RCI Type | Device/Station physical Number | Pin Number | |
---|---|---|---|
AlphaCom XE1 | Device | 65 | 1 - 2 |
Example
Start fire alarm message and activate rotating lamp:
AMG 1 3 - Alarm Message 3 (8193) to group 1 (84) RCO 5 ON – Turn on the relay that controls the lamp
AMG 1 0 – Alarm Message OFF to group 1 (84) RCO 5 OFF – Turn off the lamp
Note: Multiple commands are separated by semicolon ( ; )
Remote Control Outputs (RCO)
XE1 does not support any RCO's in the server itself. If remote control outputs are required, please use TKIS-2 kit or IP-ARIO.
Load Factory Defaults (coldstart)
Performing a cold start of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.
Factory Default procedure
- Remove the front cover of the AlphaCom XE1
- Press and hold the "Cold Start" button on the AMC-IP card
- Power up the AlphaCom XE1 while keeping the "Cold Start" button pressed
- Keep the button pressed for minmum 3 seconds after power on, then release the button
Factory Default of intercom settings only, keeping the IP setting
- Remove the front cover of the AlphaCom XE1
- Power up the AlphaCom XE1
- 10 seconds after power on, press and hold the "Cold Start" button on the AMC-IP card
- Keep the "Cold Start" button pressed until the status LED of the AMC-IP is blinking green.
Other methods of factory default
A factory default can also be achieved in other ways:
- From AlphaWeb: System Maintenance -> System Recovery -> Load Factory Defaults
- From AlphaPro: Upload a default AlphaPro database to the exchange
Additional Documentation on Zenitel.com
Mounting & Dimensions
The cabinet should be mounted on a shelf or in a 19” rack. It contains one AMC-IP processor board only. The server includes a power board.