Actions

Difference between revisions of "Anti-nuisance control (Event Handler)"

From Zenitel Wiki

m (1 revision imported)
Line 1: Line 1:
{{A}}This article describes how a master station can disable substations from making calls and audio program selection for a period of time. This function is typically used in prisons, where you want to block calls from a particular cell for a certain time.  
+
{{AI}}This article describes how a master station can disable substations from making calls and audio program selection for a period of time. This function is typically used in prisons, where you want to block calls from a particular cell for a certain time.  
  
In the programming example below the master station dials 9535 + substation directory number to disable calls from that substation for 15 minutes. The feature code 9535 and the substation numbers can be assigned to DAK keys for easy operation.  
+
In the programming example below the master station dials 9535 + substation directory number to disable calls from that substation for a preset time (15 minutes in the example below). The feature code 9535 and the substation numbers can be assigned to DAK keys for easy operation.  
  
 
If the master station is a [[Control Room Master IV|CRM IV]] or [[IP Flush Master - 1008031000|CRM V]] station with [[IP Flush Master DAK-48 Module|DAK48 panel]], the "disabled" status will be indicated with a red LED in the assosiated button on the DAK panel.
 
If the master station is a [[Control Room Master IV|CRM IV]] or [[IP Flush Master - 1008031000|CRM V]] station with [[IP Flush Master DAK-48 Module|DAK48 panel]], the "disabled" status will be indicated with a red LED in the assosiated button on the DAK panel.

Revision as of 14:20, 19 October 2021

AI.png

This article describes how a master station can disable substations from making calls and audio program selection for a period of time. This function is typically used in prisons, where you want to block calls from a particular cell for a certain time.

In the programming example below the master station dials 9535 + substation directory number to disable calls from that substation for a preset time (15 minutes in the example below). The feature code 9535 and the substation numbers can be assigned to DAK keys for easy operation.

If the master station is a CRM IV or CRM V station with DAK48 panel, the "disabled" status will be indicated with a red LED in the assosiated button on the DAK panel.

If the master station is a DualDisplay station (either analog or IP based), the "disabled" status will be highlighted with inverse video in the assosiated button in the DAK display.


Solution

Directory number 9535 is by default a two-step event trigger, feature 95/0. When 9535 + Substation is dialled, an event type 25 is triggered and the action string $SSC L%2.dir U2 moves the substation to COS 2. COS 2 is by default empty, which will prevent calls to be initiated. The command $DISCON_ST L%1.dir U2 will disconnect the master station with a success tone after having entered the substation number. The $PROG L%2.dir LV command will switch off audio program on the substation. The IND %1.phy %1.dak(I%2.dir) 1 1 ON command will turn on the red LED in the DAK48 panel if a CRMIV or CRMV station is used. A 15 minute timer (900,0 seconds) is started by the command $ST L%2.dir W9000 L9988.

When the timer expires it will trigger event type 21, and the command $SSC L%1.dir U1 will move the station back to COS 1, the IND %1.phy %1.dak(I%2.dir) 1 1 OFF command will switch off the red LED, and calls and program selection can again be made.


Event 1 - Move the substation to COS 2, start a timer, and disconnect the master station.

Event Owner: The Master Station
Event type: 25 – Event trigger with parameter
Subevent: 0
When change to: ON
When related to: All
Action: $SSC L%2.dir U2
  $DISCON_ST L%1.dir U2
  $PROG L%2.dir LV
  IND %1.phy %1.dak(I%2.dir) 1 1 ON
  $ST L%2.dir W9000 L9988

Event 2 - Move the substation back to COS 1.

Event Owner: Stations w/UDP, Id: 8 (All stations)
Event type: 21 – Event timer
When change to: ON
When related to: Directory number, Id: 9988
Action: $SSC L%1.dir U1
  OWN 110 %1.dir
  IND %1.phy %1.dak(I%2.dir) 1 1 OFF

The two last lines (OWN and IND) are required only if a DAK48 panel is used. In the example the CRM station has directory number 110. The first parameter in the OWN command must be changed according to the directory number used in your installation.

Additional notes

If there are several two-step event triggers used for different features, they must be separated by using different parameter 1 for the feature 95, i.e. 95/0, 95/1, 95/2 etc.

Example:

  • 9535 = 95/0 (default)
  • 9546 = 95/1
  • 9547 = 95/2