Actions

ATLB in AlphaCom E7 - RCO's

From Zenitel Wiki

Revision as of 13:37, 6 November 2008 by Asle (talk)
atlb

The RCO pinout towards the backplane is different on the ASLT and the ATLB.

This is not a problem when using AlphaCom E20/E26, because the ATLB connection board and the RJ45 filter board is adjusted accordingly, so the RCO's comes out correctly.

But in the AlphaCom E7 there is a direct connection from board pos. 1 and 2 to the RCO 1-6 and 7-12, designed for the ASLT card pinout.

When using ATLB in AlphaCom E7 only four RCO's are available, and they come out on different pins than what you expect:


ATLB in board position 1:

  • Logical RCO 1 (65/1) is not available
  • Logical RCO 2 (65/2) is not available
  • Logical RCO 3 (65/3) triggers physical RCO 2
  • Logical RCO 4 (65/4) triggers physical RCO 3
  • Logical RCO 5 (65/5) triggers physical RCO 4
  • Logical RCO 6 (65/6) triggers physical RCO 5


ATLB in board position 2:

  • Logical RCO 7 (65/7) is not available
  • Logical RCO 8 (65/8) is not available
  • Logical RCO 9 (65/9) triggers physical RCO 8
  • Logical RCO 10 (65/10) triggers physical RCO 9
  • Logical RCO 11 (65/11) triggers physical RCO 10
  • Logical RCO 12 (65/12) triggers physical RCO 11