Actions

Anti-nuisance control (Event Handler)

From Zenitel Wiki

Revision as of 13:13, 9 October 2007 by Asle (talk)

A master station should be able to disable calls from substations for a periode of time.

In the programming example below the master station dials 9535 + substation number to disable calls from that substation for 15 minutes.

Directory number 9535 is by default a two-step event trigger, feature 95/0. When dialled, an event type 25 is triggered and the action string $SSC L%2.dir U2 moves the station to COS 2. COS 2 is by default empty, which will prevent calls to be initiated. The command $DISCON_ST L%1.dir U2 will disconnect thwe master station with a success tone after having entered the substation number. Also a 15 minute timer is started by the command $ST L%2.dir W9000 L9999. The timer will trigger event type 21 when it times out. The command $SSC L%2.dir U1 will then move the station back to COS 1, and calls can again be made.


Event 1 - Move the substation to COS 2:

Event Owner: The Master Station
Event type: 25 – Event trigger with parameter
Subevent: 0
When change to: ON
When related to: All
Action: $SSC L%2.dir U2
  $ST L%2.dir W9000 L9999
  $DISCON_ST L%1.dir U2



Event 2 - Move the substation back to COS 1:

Event Owner: Stations w/UDP Id: 8 (All stations)
Event type: 21 – Event timer
When change to: ON
When related to: Directory number: 9999
Action: $SSC L%1.dir U1