ZDD-1

This article describes how to configure the Zenitel Display Door intercom (ZDD-1) when used in an ICX-AlphaCom system. The ZDD-1 must be configured in SIP mode, and a SIP account must be created in the ICX-AlphaCom.

License requirement

When using the Zenitel Display Door intercom (ZDD-1) in an ICX-AlphaCom system a SIP Station license ILS-SIP is required for the ZDD-1.

Configuration

Create a SIP Account in ICX-AlphaCom

Configuration of the ZDD-1

  1. Log on to the device
  2. Main Settings: Go to Main > Main Settings and set "Mode" = SIP. Enter the IP Settings for the device.
  3. Account Settings: Select SIP Configuration > Account/Call and enter as a minimum Display Name, Directory Number, Server Domain and Authentication User Name.
  4. GUI and Display configuration


Door Opening Feature

During a call between ZDD-1 and a master station, the master station operator can activate the Door Opening feature in the ICX-AlphaCom by pressing digit 6.

The Door Opening feature is programmed in the Event Handler. An event must be created to send the digit "6" as a DTMF signal to the ZDD-1.

In AlphaPro, open Users & Stations, select the ZDD-1 and press Events. In the Events window press Insert and create the following event:

Door Opening event for ZDD-1



Action commands:

$D2S L%1.dir 6 1
pause
$D2S L%1.dir 6 0



Additional info