Actions

Difference between revisions of "IP-LCM Configuration (AlphaCom mode)"

From Zenitel Wiki

Line 25: Line 25:
  
  
Input actions are configured in the [[Event Handler]] of the AlphaCom server. Inputs will trigger the event 30, and the Sub-Event is used to identify which input is being triggered.
+
Input actions are configured in the [[Event Handler]] of the AlphaCom server. Inputs will trigger the event [[Station Input or Station DAK key (Event Type)|30 - Station Input or Station DAK key]], and the Sub-Event is used to identify which input is being triggered.
  
  

Revision as of 14:08, 17 April 2019

AlphaCom icon 300px.png

This article describes how to configure the IP-LCM Module when used with an AlphaCom server.

Basic configuration

The IP-LCM requires an IP Station License in the AlphaCom server in order to get registered.

To make a IP-LCM Module operational there are essentially four parameters to set in the web interface of the module. Log In to the module, go to Station Main > Main Settings, and:

  1. Set Station Mode = "Use AlphaCom"
  2. Configure the IP Settings (IP address) of the IP-LCM
  3. Enter the AlphaCom IP-address
  4. Enter Station Directory Number


The Directory Number must be defined in the AlphaCom Server using the AlphaPro configuration tool.

Inputs

The IP-LCM module has in total 14 inputs:

  • 6 inputs on the The TKIS-2 module itself
  • 8 inputs on the IP-LCM board
IP-LCM Inputs.png


  • The six inputs on the TKIS-2 module are triggered by connecting the Input to GND via a closed contact.
  • Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See IP-LCM Connections for details.


Input actions are configured in the Event Handler of the AlphaCom server. Inputs will trigger the event 30 - Station Input or Station DAK key, and the Sub-Event is used to identify which input is being triggered.


Outputs