In [[AlphaPro]], go to [[Users & Stations (AlphaPro)|Users & Stations]], and select the IP-LCM from the list box. Select '''Events''', and '''Insert''' a new event with the following properties:
 
In [[AlphaPro]], go to [[Users & Stations (AlphaPro)|Users & Stations]], and select the IP-LCM from the list box. Select '''Events''', and '''Insert''' a new event with the following properties:
 +
 +
 +
[[File:IP-LCM InputEvent30.png|thumb|left|600px]]
 +
<br style="clear:both;" />
  
 
== Outputs ==
 
== Outputs ==
  
 
* The 8 relays must be mapped to RCO pins 17-24, see [[RCO - Remote Control Output]]
 
* The 8 relays must be mapped to RCO pins 17-24, see [[RCO - Remote Control Output]]

Revision as of 14:23, 17 April 2019

AlphaCom icon 300px.png

This article describes how to configure the IP-LCM Module when used with an AlphaCom server.

Basic configuration

The IP-LCM requires an IP Station License in the AlphaCom server in order to get registered.

To make a IP-LCM Module operational there are essentially four parameters to set in the web interface of the module. Log In to the module, go to Station Main > Main Settings, and:

  1. Set Station Mode = "Use AlphaCom"
  2. Configure the IP Settings (IP address) of the IP-LCM
  3. Enter the AlphaCom IP-address
  4. Enter Station Directory Number


The Directory Number must be defined in the AlphaCom Server using the AlphaPro configuration tool.

Inputs

The IP-LCM module has in total 14 inputs:

  • 6 inputs on the The TKIS-2 module itself
  • 8 inputs on the IP-LCM board
IP-LCM Inputs.png


  • The six inputs on the TKIS-2 module are triggered by connecting the Input to GND via a closed contact.
  • Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See IP-LCM Connections for details.

Input actions are configured in the Event Handler of the AlphaCom server. Inputs will trigger the event 30 - Station Input or Station DAK key, and the Sub-Event is used to identify which input is being triggered.

In AlphaPro, go to Users & Stations, and select the IP-LCM from the list box. Select Events, and Insert a new event with the following properties:


IP-LCM InputEvent30.png


Outputs