Examples of RCI usage

A Remote Control Input(RCI) is triggered by an external potential-free contact. The RCI is very flexible - almost any feature in the AlphaCom can be activated.

Typical external triggers are fire and gas alarm systems, temperature detectors, doors, lifts, alarm buttons etc.

The AlphaCom XE supports up to 140 inputs.

An RCI signal can be received by a number of devices:

Device # of RCI's
AlphaCom XE20/26 6
AlphaCom XE7/1 2
IPARIO unit (IP) 8
RIO unit (analog) 8
IP Substation 3
IP Flush Master 3
RCI inputs in an AlphaCom XE20 and XE26
RCI inputs in an AlphaCom XE7

It is possible to connect multiple RIO units to one AlphaCom. Maximum number of RCIs in an AlphaCom exchange is 140.

The set-up for the RCI input and the actions you want it to activate is very flexible. An RCI can activate almost any function in the exchange by using Built-In Action Commands, Event Report or Data Protocol Commands. The programming is done with the AlphaPro programming tool.

Some examples:

  • Dialing of numbers, activating key-press on a station.
  • Sending mail message to a station or a group of stations.
  • Setting up/disconnect groups, programs and conferences.
  • Activate transfer of calls.
  • Control of RCO output.
  • Perform system reset.
  • Activate Wake-up function

etc.

In AlphaPro there is an RCI table, where the physical address is entered, along with the desired actions. The physical address is given as device + pin-number.

  • For internal RCIs, the device address is 65-68, and the pin number is 1-6.
  • Internal pin number 8 is the temperature alarm.
  • Mappings for the internal RCIs in the master are autoloaded. Mappings for RCIs in slave modules and RIO units must be manually programmed.


See also:

Additional Information

Software

  • AMC 10.50 or later can use RCIs in slave module (devices 66-68). (SW in the slave modules must also be upgraded)
  • AMC 07.20 or later to have access to all features.
  • AMC earlier than 07.20 has the following access to control features:
    • Mail message to a station or a group of stations.
    • Mail message to a pocket pager.
    • Mail message with notification to a station or a group of stations.
    • Audio program to a station or to a group of stations .
    • Conference set-up for a group of stations (may include mobile units).
    • Turn Remote Control Output (RCO) ON or OFF.
    • Handset/volume override for a group of stations.
    • Generate customized serial data output (External Data Output EDO).
    • The RCI activation (ON and OFF) can be logged on printer or PC.