TFIX V2 - Installation Solutions
From Zenitel Wiki
Contents
TFIX V2 station with external speaker and signal device
In noisy areas an external speaker and/or a beacon lamp can be used to indicate an incoming call or PA announcement.
Single TFIX V2 with external speaker and beacon
A single TFIX V2 with external speaker and beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Flowire unit; FCDC3 (item 1008080310)
- 1 48VDC Flowire PSU (item 2990000065)
- 1 48VDC PSU for external speaker and beacon (item 2990000065)
A junction box is needed out in the field to split the 48VDC between the TFIX V2 second power input and the beacon.
- 1 Junction Box (item 2340110016)
Multiple TFIX'es with external signal device
Multiple TFIX'es with external signal device in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:
- 1 Turbine extended kit; TKIE
- 1 Turbine Relay board; TA-10
- 1 24VDC or 230VAC PSU for external signal device
- 1 Flowire unit; FCDC2
- 1 24VDC Flowire PSU
Multiple TFIX'es with external signal device in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:
- 1 Turbine compact Kit; TKIS-2
- 1 Multi-relay board; MRBD
- 1 24VDC PSU: for the MRBD
- 1 Flowire unit; FCDC2
- 1 24VDC Flowire PSU
- 6 Relay boxes; IRR-3
- 6 External signal devices; Beacon BEX24O/BEX230O, or Signal bell/horn DHW2-24/DHH1-230
- 6 24VDC or 230VAC PSU for external signal device