The STENTOFON Vandal Resistant '''IP Video Station''' (item 1401110100) is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance. Designed for CCoIP® the station offers a set of critical communication features such as integrated firewall, group call, call priority and over-ride, to name just a few. This enables you to deliver instant, efficient and secure voice, video and data services in an IP environment.
+
== Connections ==
 +
* [[IP Video Doorstation Connections|Intercom connections]]
  
=Configuration=
+
==Configuration==
==CCoIP Station==
+
The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure.  
The station must be given an IP address, either static or one provided by a DHCP server. In addition the IP address of the AlphaCom and the directory number must be set. This is all done in the inbuilt webserver.  
 
  
For more details, please see: [[IP_Station_Configuration#Station_Main_Settings|IP Station IP and Server configuration]]
+
General configuration:
 +
* [[IP Station Configuration - ICX-AlphaCom mode]]
 +
* [[Adding station to existing system (Edge)|IP Station Configuration - Edge mode]]
 +
* [[SIP Intercom - Web Interface|IP Station Configuration - SIP mode]]
 +
* [[IP Station Configuration - Pulse mode]]
  
<br style="clear:both;" />
+
Station specific configuration:
 +
* [[CP Cam Configuration]]
  
==Camera==
+
== Restore Factory Defaults and Software Upgrade ==
Connect to the camera using a webbrowser on default IP address 169.254.1.101.
+
* [[INCA Station Restore Factory Defaults|Factory reset of the intercom station]]
 +
* [[CP-Cam Factory Reset|Factory reset of the Camera Module]]
 +
* [[INCA Station Software upgrade|Upgrade via the station web interface]]
 +
* [[IMT - Discover & Upgrade|Upgrade using the IMT tool]]
 +
* CP Cam upgrade
 +
* [[Automatic Software Upgrade|Automatic Software Upgrade (SIP mode only)]]
 +
* [[:Category:INCA Release notes|Software Release Notes]]
  
In the menu that appears, click '''System Settings''', and you will be asked to login:
+
== Connectors, Indicators and Dimensions ==
 +
*[[INCA Video Doorstation Board Connectors|Board Connectors]]
 +
* [[INCA Video Doorstation LED Indicators|Station LED Indications]]
 +
* [[INCA Substation PCB LED Indicators|PCB LED Indications]]
 +
* [[IP Video Doorstation Dimensions & Mounting Instructions|Dimensions]]
  
Username: '''admin''' <br/>
+
== Accessories ==
Password: '''1234'''
+
* [[Back box flush mount - 1401199101]]
 +
* [[Back box on wall mount - 1401199111]]
 +
* [[Protection Roof - 1401199112]]
  
Set to factory default:
+
== Software Requirements ==
===CP-Cam Factory Reset===
+
This station is fully supported as form AlphaCom version 10.20
'''This should be carried out only by experienced technicians. The customer is liable for damages caused by improper opening of the housing. '''
 
  
If the entered IP address is unknown, it is possible to reset the address to 169.254.1.101 using the DIP switch. To proceed, the unit must be opened.
+
== Additional information ==
''Note: A change of the IP address is made via the web interface of the CP-CAM.''
+
* [http://www.zenitel.com/product/ip-vandal-resistant-video-intercom-station-w-cp-cam-camera Additional Documentation on Zenitel.com]
The procedure is as follows:
 
:1. Open the CP-CAM so the two DIP switches are accessible ( see picture ).
 
:2.  Note the switch position and then turn both switches to „OFF“.
 
:3.  Connect PC with the IP number range 169.254.1.xxx and set the desired IP address in the web interface.
 
:4.  Turn switch positions back to original positions.
 
:5.  Close housing properly.
 
  
[[File:CP-CAM.PNG|thumb|500px|left]]
 
<br style="clear:both;" />
 
  
=Setup with STENTOFON Video Display Station=
+
[[Category: Discontinued Stations]]
To configure the STENTOFON Video Display Station please see: [[IP Desktop Station with Video Display - 1408001635]]
 
 
 
This chapter describes the steps for configuring the CP-Cam:
 
 
 
From the Main Menu select '''System Settings > Network'''
 
:1. Under section '''IP-SETUP''', set ''IP-SETUP Type'' to '''Manual'''
 
[[File:IP-VideoDoorStation1.png|left|thumb|500px]]
 
<br style="clear:both;" />
 
:2. Enter a static IP adresss, Netmask, Gateway and DNS
 
:3. Under section '''System''', set ''Authentication required for Picture/Video'' to '''No'''
 
[[File:IP-VideoDoorStation2.png|left|thumb|500px]]
 
<br style="clear:both;" />
 
:4. Click '''Save Changes''' at the bottom of the page
 
<br style="clear:both;" />
 
----
 
 
 
From the Main Menu select '''System Settings > Camera'''
 
:1. Under section '''Settings''', set ''Mode'' to '''Custom'''
 
:2. Set '''Res X''' to 320
 
:3. Set '''Res Y''' to 240
 
[[File:IP-VideoDoorStation3.png|left|thumb|500px]]
 
<br style="clear:both;" />
 
:4. Under section '''Settings''', set ''Frames per Second (Sensor)'' to '''15'''
 
[[File:IP-VideoDoorStation4.png|left|thumb|500px]]
 
<br style="clear:both;" />
 
 
 
 
 
 
 
[[Category: Stations]]
 
[[Category: IP Stations]]
 
 
[[Category:Video]]
 
[[Category:Video]]

Latest revision as of 08:24, 16 August 2022

Obsolete icon This product is discontinued!


AEIPS.png
IP Video Station with CP-CAM camera, item 1401110100

Connections

Configuration

The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure.

General configuration:

Station specific configuration:

Restore Factory Defaults and Software Upgrade

Connectors, Indicators and Dimensions

Accessories

Software Requirements

This station is fully supported as form AlphaCom version 10.20

Additional information