− | {{AEIPS}}[[ | + | {{AEIPS}} |
+ | The '''IP-LCM module''' is an expansion to the [[TKIS-2]], and adds high power relays and robust control inputs to the kit without extra wiring. | ||
− | + | DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems. | |
− | DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems. < | + | <table style="float:right; max-width:80%; border-style: double; border-color: #c7c7c7;"> |
− | + | <tr style="rowspan:2;"> | |
+ | <td style="display: block; vertical-align: bottom;">[[Image:IP-LCM v1.1.png|500px]]</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style='background-color:#efefef;'>IP Line Connection Module (1008095201)</td> | ||
+ | </tr> | ||
+ | </table> | ||
− | *8 relay outputs | + | The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems. |
− | *8 control inputs | + | * 8 relay outputs |
− | *Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG | + | * 8 control inputs |
− | *Device powered via the TKIS-2 kit using PoE or local power | + | * Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG |
− | *All [[TKIS-2]] features are available, including: | + | * Device powered via the TKIS-2 kit using PoE or local power |
− | **1 relay | + | * All [[TKIS-2]] features are available, including: |
− | **6 inputs | + | ** 1 relay |
+ | ** 6 inputs | ||
+ | ** 0dB Line Out | ||
+ | * As from HW version 1.1 there is also 0dB Line In available. | ||
In general Zenitel offers a number of IP based kits, which can be used for a wide range of applications. See the [[Kits - Comparison chart|kit comparison chart]]. | In general Zenitel offers a number of IP based kits, which can be used for a wide range of applications. See the [[Kits - Comparison chart|kit comparison chart]]. | ||
− | == | + | ==License Requirements== |
− | + | ||
+ | * An [[Licenses_for_ICX-500_and_ICX-AlphaCom_Core#Available_licenses|IP Station License is required for ICX-AlphaCom]]. | ||
+ | * An [[Licenses#IP_station_license|IP Station License is required in the AlphaCom]]. | ||
− | |||
− | + | Even if only the I/O part of the IP-LCM is used a license is required. | |
− | |||
==Getting started== | ==Getting started== | ||
− | + | * [[Starting Up Turbine Station|Starting up]] | |
− | |||
− | *[[Starting Up Turbine Station|Starting up]] | ||
==Configuration== | ==Configuration== | ||
Line 37: | Line 45: | ||
Device specific configuration for the IP-LCM: | Device specific configuration for the IP-LCM: | ||
− | *[[IP-LCM Configuration (AlphaCom | + | *[[IP-LCM Configuration (ICX-AlphaCom)|ICX-AlphaCom mode]] |
*[[Relay_Settings_(Edge)#Operating the relay of a Remote Device|Edge mode]] | *[[Relay_Settings_(Edge)#Operating the relay of a Remote Device|Edge mode]] | ||
*[[Relay_Settings_(SIP)|SIP mode]] | *[[Relay_Settings_(SIP)|SIP mode]] | ||
Line 45: | Line 53: | ||
*[[TKIS Restore Factory Defaults|Restore Factory Defaults]] | *[[TKIS Restore Factory Defaults|Restore Factory Defaults]] | ||
*[[Turbine Software Upgrade|Upgrade via the station web interface]] | *[[Turbine Software Upgrade|Upgrade via the station web interface]] | ||
− | *[[ | + | *[[IMT - Discover & Upgrade|Upgrade using the IMT tool]] |
* [[:Category:IMX28 Release notes|Software Release Notes]] | * [[:Category:IMX28 Release notes|Software Release Notes]] | ||
==Connectors, Indicators and Dimensions== | ==Connectors, Indicators and Dimensions== | ||
+ | * [[IP-LCM Connections|Device Connections]] | ||
+ | * [[IP-LCM Dimensions & Mounting Instructions|Dimensions]] | ||
− | + | ==Software Requirements== | |
− | + | The IP-LCM is fully supported from device version 4.11.x.x | |
− | |||
When used in AlphaCom mode, this device is fully supported as from AlphaCom version 11.2.3.7 | When used in AlphaCom mode, this device is fully supported as from AlphaCom version 11.2.3.7 | ||
− | ==Additional Documentation on Zenitel.com | + | ==Related Information== |
+ | *[[VoIP kit as PA Interface]] | ||
+ | *[http://www.zenitel.com/product/ip-lcm Additional Documentation on Zenitel.com] | ||
− | |||
[[Category: Turbine]] | [[Category: Turbine]] | ||
− | [[Category:Additional equipment]] | + | [[Category: Additional equipment]] |
− | [[Category:Public Address - Interfaces]] | + | [[Category: Public Address - Interfaces]] |
Revision as of 14:47, 22 April 2024
The IP-LCM module is an expansion to the TKIS-2, and adds high power relays and robust control inputs to the kit without extra wiring.
DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems.
IP Line Connection Module (1008095201) |
The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems.
- 8 relay outputs
- 8 control inputs
- Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG
- Device powered via the TKIS-2 kit using PoE or local power
- All TKIS-2 features are available, including:
- 1 relay
- 6 inputs
- 0dB Line Out
- As from HW version 1.1 there is also 0dB Line In available.
In general Zenitel offers a number of IP based kits, which can be used for a wide range of applications. See the kit comparison chart.
Contents
License Requirements
- An IP Station License is required for ICX-AlphaCom.
- An IP Station License is required in the AlphaCom.
Even if only the I/O part of the IP-LCM is used a license is required.
Getting started
Configuration
General configuration:
Device specific configuration for the IP-LCM:
Restore Factory Defaults and Software Upgrade
- Restore Factory Defaults
- Upgrade via the station web interface
- Upgrade using the IMT tool
- Software Release Notes
Connectors, Indicators and Dimensions
Software Requirements
The IP-LCM is fully supported from device version 4.11.x.x
When used in AlphaCom mode, this device is fully supported as from AlphaCom version 11.2.3.7