[[File:IP-LCM 1.jpg|thumb|350px|IP Line Connection Module ( 1008095201)]]
+
The '''IP-LCM module''' is an expansion to the [[TKIS-2]], and adds high power relays and robust control inputs to the kit without extra wiring.
  
==Highlights==
+
DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems.
The IP-LCM module is an expansion to the TKIS-2 that adds high power relays and robust control inputs to the kit without extra wiring. <br/>
+
<table style="float:right; max-width:80%; border-style: double; border-color: #c7c7c7;">
DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems. <br/>
+
<tr style="rowspan:2;">
The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems.<br/>
+
<td style="display: block; vertical-align: bottom;">[[Image:IP-LCM v1.1.png|500px]]</td>
 +
</tr>
 +
<tr>
 +
<td style='background-color:#efefef;'>IP Line Connection Module (1008095201)</td>
 +
</tr>
 +
</table>
  
 +
The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems.
 
* 8 relay outputs
 
* 8 relay outputs
 
* 8 control inputs
 
* 8 control inputs
 
* Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG
 
* Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG
 
* Device powered via the TKIS-2 kit using PoE or local power
 
* Device powered via the TKIS-2 kit using PoE or local power
* All TKIS-2 features available
+
* All [[TKIS-2]] features are available in addition, including:
SIP, Pulse, Exigo and AlphaCom are supported.
+
** 1 relay
 +
** 6 I/Os
 +
** Analog 0dB Line Out
 +
** Analog 0dB Line In (as from hardware version 1008131020.'''0200''')
  
==I/O's==
+
In general Zenitel offers a number of IP based kits, which can be used for a wide range of applications. See the [[Kits - Comparison chart|kit comparison chart]].
The onboard TKIS-2 has 6 I/O's and a relay that function as normal. <br/>
 
See [[TKIS-2]] article for details.
 
  
In AlphaCom mode the 8 inputs report as DAK 18-25.
+
==License Requirements==
  
The 8 relays are controlled as pin numbers 17-24.
+
* An [[Licenses_for_ICX-500_and_ICX-AlphaCom_Core#Available_licenses|IP Station License is required for ICX-AlphaCom]].
 +
* An [[Licenses#IP_station_license|IP Station License is required in the AlphaCom XE]].  
  
== Getting started ==
+
 
* [[TKIS Connections|Connections]]
+
Even if only the I/O part (no audio) of the IP-LCM is used a license is required.
 +
 
 +
==IP-LCM hardware versions==
 +
There are two hardware versions:
 +
* Version 1008131020.01xx: Original version
 +
* Version 1008131020.0200: Added support for analog Line In
 +
 
 +
Hardware version 1008131020.0200 can be visually identified by:
 +
** The TKIS-2 kit assembled with the text in same orientation as circuit board text
 +
** Zenitel logo with V1.1 print
 +
** Line-in connector - J104
 +
** Item number ending with .0200
 +
 
 +
==Getting started==
 
* [[Starting Up Turbine Station|Starting up]]
 
* [[Starting Up Turbine Station|Starting up]]
  
== Configuration ==
+
==Configuration==
* [[IP-LCM Configuration - AlphaCom mode|AlphaCom mode]]
+
General configuration:
  
== Restore Factory Defaults and Software Upgrade ==
+
* [[IP Station Configuration - ICX-AlphaCom mode|ICX-AlphaCom mode]]
* [[TKIS Restore Factory Defaults|Restore Factory Defaults]]
+
* [[Adding station to existing system (Edge)|Edge mode]]
* [[Turbine Software Upgrade|Upgrade via the station web interface]]
+
* [[SIP Intercom - Web Interface|SIP mode]]
  
== Connectors, Indicators and Dimensions ==
+
Device specific configuration for the IP-LCM:
* [[IP-LCM Compact Board Connectors|Board Connections]]
+
 
* [[TKIS Indication LEDs|Station Indication LEDs]]
+
*[[IP-LCM Configuration (ICX-AlphaCom)|ICX-AlphaCom mode]]
* [[IP-LCM Indication LEDs|IP-LCM Indication LEDs]]
+
*[[Relay_Settings_(Edge)#Operating the relay of a Remote Device|Edge mode]]
 +
*[[Relay_Settings_(SIP)|SIP mode]]
 +
 
 +
==Restore Factory Defaults and Software Upgrade==
 +
 
 +
*[[TKIS Restore Factory Defaults|Restore Factory Defaults]]
 +
*[[Turbine Software Upgrade|Upgrade via the station web interface]]
 +
*[[IMT - Discover & Upgrade|Upgrade using the IMT tool]]
 +
* [[:Category:IMX28 Release notes|Software Release Notes]]
 +
 
 +
==Connectors, Indicators and Dimensions==
 +
* [[IP-LCM Connections|Device Connections]]
 
* [[IP-LCM Dimensions & Mounting Instructions|Dimensions]]
 
* [[IP-LCM Dimensions & Mounting Instructions|Dimensions]]
  
== Additional Documentation on Zenitel.com ==
+
==Software Requirements==
* [http://www.zenitel.com/product/ip-lcm Additional Documentation on Zenitel.com]
+
The IP-LCM is fully supported from device version 4.11.x.x
 +
 
 +
When used in AlphaCom mode, this device is fully supported as from AlphaCom version 11.2.3.7
 +
 
 +
==Related Information==
 +
*[[VoIP kit as PA Interface]]
 +
*[http://www.zenitel.com/product/ip-lcm Additional Documentation on Zenitel.com]
 +
 
  
[[Category:Additional equipment]]
+
[[Category: Turbine]]
[[Category:Public Address - Interfaces]]
+
[[Category: Additional equipment]]
 +
[[Category: Public Address - Interfaces]]

Latest revision as of 10:26, 20 June 2024

AEIPS.png

The IP-LCM module is an expansion to the TKIS-2, and adds high power relays and robust control inputs to the kit without extra wiring.

DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems.

IP-LCM v1.1.png
IP Line Connection Module (1008095201)

The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems.

  • 8 relay outputs
  • 8 control inputs
  • Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG
  • Device powered via the TKIS-2 kit using PoE or local power
  • All TKIS-2 features are available in addition, including:
    • 1 relay
    • 6 I/Os
    • Analog 0dB Line Out
    • Analog 0dB Line In (as from hardware version 1008131020.0200)

In general Zenitel offers a number of IP based kits, which can be used for a wide range of applications. See the kit comparison chart.

License Requirements


Even if only the I/O part (no audio) of the IP-LCM is used a license is required.

IP-LCM hardware versions

There are two hardware versions:

  • Version 1008131020.01xx: Original version
  • Version 1008131020.0200: Added support for analog Line In

Hardware version 1008131020.0200 can be visually identified by:

    • The TKIS-2 kit assembled with the text in same orientation as circuit board text
    • Zenitel logo with V1.1 print
    • Line-in connector - J104
    • Item number ending with .0200

Getting started

Configuration

General configuration:

Device specific configuration for the IP-LCM:

Restore Factory Defaults and Software Upgrade

Connectors, Indicators and Dimensions

Software Requirements

The IP-LCM is fully supported from device version 4.11.x.x

When used in AlphaCom mode, this device is fully supported as from AlphaCom version 11.2.3.7

Related Information