The '''ENA2200 Amplifier''' is a 2 x 200 watt IP based amplifier that can register to the AlphaCom server over an IP network.
 
The '''ENA2200 Amplifier''' is a 2 x 200 watt IP based amplifier that can register to the AlphaCom server over an IP network.
  
 
The ENA2200 amplifier operates from a primary 115/230 VAC supply and have automatic uninterrupted switch-over to a secondary 24-48 VDC supply if the primary should fail. The amplifier will continue to operate with full service during and after the switch-over.
 
The ENA2200 amplifier operates from a primary 115/230 VAC supply and have automatic uninterrupted switch-over to a secondary 24-48 VDC supply if the primary should fail. The amplifier will continue to operate with full service during and after the switch-over.
  
The ENA amplifier has two separate loudspeaker channels. Each channel can be addressed separately, i.e. belong to two different zones, or the two channels can be combined into one channel.
+
The ENA amplifier has two separate loudspeaker channels. Each channel can be addressed separately, i.e. belong to two different zones.
  
 
The ENA amplifier monitors the speaker lines for shorts, overload and opens. A [[ELTSI-1|Line End Transponder (ELTSI)]] can be used for reliable detection of an open line. More than one ELTSI can be connected to the same line, allowing monitoring of several branches on the speaker line. The amplifier also monitors control inputs, power, temperature, network connections and every other component required for operation of essential services. Faults will be indicated locally on the [[ENA User Interface|amplifier display]] and fault relay, as well as reported to the AlphaCom server which can raise an event or forward the reports to syslog, SNMP and internal log.
 
The ENA amplifier monitors the speaker lines for shorts, overload and opens. A [[ELTSI-1|Line End Transponder (ELTSI)]] can be used for reliable detection of an open line. More than one ELTSI can be connected to the same line, allowing monitoring of several branches on the speaker line. The amplifier also monitors control inputs, power, temperature, network connections and every other component required for operation of essential services. Faults will be indicated locally on the [[ENA User Interface|amplifier display]] and fault relay, as well as reported to the AlphaCom server which can raise an event or forward the reports to syslog, SNMP and internal log.
Line 15: Line 18:
  
 
== Configuration ==
 
== Configuration ==
* [[ENA Amplifier - Basic configuration|Basic configuration - Getting started]]
+
===AlphaCom mode===
* [[ENA Configuration - AlphaCom mode|ENA Amplifier configuration - General guide]]
+
* [[ENA Amplifier - Basic configuration (AlphaCom mode)|Getting started (AlphaCom mode)]]
* [[ENA Amplifier - Monitoring|Monitoring of the amplifier]]
+
* [[ENA Configuration - AlphaCom mode|AlphaCom mode]]
 +
* [[ENA Amplifier - Monitoring|Amplifier monitoring]]
 +
* [[ENA Amplifier - Report faults to Display Station|Report amplifier faults to Display Station]]
 
* [[HD audio for background music distribution]]
 
* [[HD audio for background music distribution]]
* [[ENA amplifier in Standalone Mode]]
+
* [[Distributed Automatic Volume Control (DAVC)]]
 +
 
 +
===SIP mode ===
 +
* [[ENA Amplifier - Basic configuration (SIP mode)|Getting Started (SIP mode)]]
 +
* [[ENA Amplifier Configuration (SIP)|Web interface - SIP mode]]
 +
* [[Distributed Automatic Volume Control (DAVC) (SIP)|Distributed Automatic Volume Control (DAVC) in SIP]]
 +
 
 +
=== Common Configuration ===
 +
* [[ENA Amplifier - Calibrating the loudspeaker lines|Calibrating the loudspeaker lines]]
 +
* [[ENA amplifier in Bypass Mode]]
  
 
== Software Upgrade and Restore Factory Defaults ==
 
== Software Upgrade and Restore Factory Defaults ==
 
The ENA amplifier is a "Turbine" device, and the software is upgraded in the same way as Turbine Intercom stations.
 
The ENA amplifier is a "Turbine" device, and the software is upgraded in the same way as Turbine Intercom stations.
 
* [[Turbine Software Upgrade|Upgrade using the web interface of the amplifier]]
 
* [[Turbine Software Upgrade|Upgrade using the web interface of the amplifier]]
* [[VS-IMT Upgrade Stations|Upgrade using the IMT tool]]
+
* [[IMT - Discover & Upgrade|Upgrade using the IMT tool]]
  
Laod Factory Default values:
+
Load Factory Default values:
* To load default configuration and reset to DHCP, press and hold the [[ENA User Interface|control knob]] for 20 seconds while booting up the Amplifier.
+
* To load default configuration and reset to DHCP, press and hold the [[ENA User Interface|menu selection knob]] for 20 seconds while booting up the Amplifier.
 
* Factory Default values can also be loaded via the web interface of the amplifier, from the [[ENA_Configuration_-_AlphaCom_mode#Station_Administration_tab|Station Administration > Reboot]] menu
 
* Factory Default values can also be loaded via the web interface of the amplifier, from the [[ENA_Configuration_-_AlphaCom_mode#Station_Administration_tab|Station Administration > Reboot]] menu
  
Line 36: Line 50:
 
* [https://www.zenitel.com/product/ena2200 Additional Documentation on Zenitel.com]
 
* [https://www.zenitel.com/product/ena2200 Additional Documentation on Zenitel.com]
  
[[Category: Public Address]]
+
[[Category: Discontinued Stations]]

Latest revision as of 11:30, 27 June 2024

Obsolete icon This product is discontinued!


Note icon This product is replaced by the ENA2200-AC2 Amplifier


AS.png
ENA2200.
The ENA2200 amplifier

The ENA2200 Amplifier is a 2 x 200 watt IP based amplifier that can register to the AlphaCom server over an IP network.

The ENA2200 amplifier operates from a primary 115/230 VAC supply and have automatic uninterrupted switch-over to a secondary 24-48 VDC supply if the primary should fail. The amplifier will continue to operate with full service during and after the switch-over.

The ENA amplifier has two separate loudspeaker channels. Each channel can be addressed separately, i.e. belong to two different zones.

The ENA amplifier monitors the speaker lines for shorts, overload and opens. A Line End Transponder (ELTSI) can be used for reliable detection of an open line. More than one ELTSI can be connected to the same line, allowing monitoring of several branches on the speaker line. The amplifier also monitors control inputs, power, temperature, network connections and every other component required for operation of essential services. Faults will be indicated locally on the amplifier display and fault relay, as well as reported to the AlphaCom server which can raise an event or forward the reports to syslog, SNMP and internal log.

The amplifier’s control inputs/outputs and audio inputs can be used locally by the amplifier (e.g. for PTT and audio from a handheld microphone) or can be controlled by the system (e.g. audio input for background music).

Installation, Mounting and Dimensions

Configuration

AlphaCom mode

SIP mode

Common Configuration

Software Upgrade and Restore Factory Defaults

The ENA amplifier is a "Turbine" device, and the software is upgraded in the same way as Turbine Intercom stations.

Load Factory Default values:

  • To load default configuration and reset to DHCP, press and hold the menu selection knob for 20 seconds while booting up the Amplifier.
  • Factory Default values can also be loaded via the web interface of the amplifier, from the Station Administration > Reboot menu

Accessories

Related Information