{{AIS}}[[File:ENA2100-AC-4.jpg|thumb|400px|ENA2100-AC amplifier (1023102100)|alt=]]
 
The '''ENA2100-AC Amplifier''' is a 2 x 100 watt IP based amplifier that can register to the AlphaCom server over an IP network.
 
The '''ENA2100-AC Amplifier''' is a 2 x 100 watt IP based amplifier that can register to the AlphaCom server over an IP network.
  
Line 9: Line 12:
  
 
The amplifier’s control inputs/outputs and audio inputs can be used locally by the amplifier (e.g. for PTT and audio from a handheld microphone) or can be controlled by the system (e.g. audio input for background music).
 
The amplifier’s control inputs/outputs and audio inputs can be used locally by the amplifier (e.g. for PTT and audio from a handheld microphone) or can be controlled by the system (e.g. audio input for background music).
== Installation, Mounting and Dimensions ==
+
==Installation, Indicators and Dimensions==
* [[ENA Amplifier - Mounting and Installation|Mounting and Installation]]
 
* [[ENA2400-AC - Dimensions|Dimensions]]
 
* [[ENA User Interface|Amplifier GUI Display]]
 
  
== Configuration ==
+
*[[ENA2100-AC Amplifier - Mounting and Installation|Mounting and Installation]]
* [[ENA Amplifier - Basic configuration|Basic configuration - Getting started]]
+
*[[ENA2100-AC - Dimensions|Dimensions]]
* [[ENA Configuration - AlphaCom mode|General configuration guide]]
+
*[[ENA2100 Status LEDs|Status LEDs]]
* [[ENA Amplifier - Monitoring|Amplifier monitoring]]
 
* [[ENA Amplifier - Calibrating the loudspeaker lines|Calibrating the loudspeaker lines]]
 
* [[ENA Amplifier - Report faults to Display Station|Report amplifier faults to Display Station]]
 
* [[HD audio for background music distribution]]
 
* [[ENA amplifier in Standalone Mode]]
 
  
== Software Upgrade and Restore Factory Defaults ==
+
==Configuration==
 +
===AlphaCom mode===
 +
 
 +
*[[ENA Amplifier - Basic configuration (AlphaCom mode)|Getting started (ICX-AlphaCom mode)]]
 +
*[[ENA Configuration - AlphaCom mode|ICX-AlphaCom mode]]
 +
*[[ENA Amplifier - Monitoring|Amplifier monitoring]]
 +
*[[ENA Amplifier - Report faults to Display Station|Report amplifier faults to Display Station]]
 +
*[[HD audio for background music distribution]]
 +
*[[Distributed Automatic Volume Control (DAVC)]]
 +
 
 +
===SIP mode===
 +
 
 +
*[[ENA Amplifier - Basic configuration (SIP mode)|Getting Started (SIP mode)]]
 +
* [[ENA Amplifier Configuration (SIP)|Web interface - SIP mode]]
 +
*[[Distributed Automatic Volume Control (DAVC) (SIP)|Distributed Automatic Volume Control (DAVC) in SIP]]
 +
 
 +
===Common Configuration===
 +
 
 +
*[[ENA Amplifier - Calibrating the loudspeaker lines|Calibrating the loudspeaker lines]]
 +
*[[ENA amplifier in Bypass Mode]]
 +
*[[ENA2100 - One Channel Mode|One Channel Mode]]
 +
 
 +
==Software Upgrade and Restore Factory Defaults==
 
The ENA amplifier is a "Turbine" device, and the software is upgraded in the same way as Turbine Intercom stations.
 
The ENA amplifier is a "Turbine" device, and the software is upgraded in the same way as Turbine Intercom stations.
* [[Turbine Software Upgrade|Upgrade using the web interface of the amplifier]]
+
 
* [[VS-IMT Upgrade Stations|Upgrade using the IMT tool]]
+
*[[Turbine Software Upgrade|Upgrade using the web interface of the amplifier]]
 +
*[[IMT - Discover & Upgrade|Upgrade using the IMT tool]]
  
 
Load Factory Default values:
 
Load Factory Default values:
* To load default configuration and reset to DHCP, press and hold the [[ENA User Interface|menu selection knob]] for 20 seconds while booting up the Amplifier.
 
* Factory Default values can also be loaded via the web interface of the amplifier, from the [[ENA_Configuration_-_AlphaCom_mode#Station_Administration_tab|Station Administration > Reboot]] menu
 
  
== Accessories ==
+
*Factory Default values can be loaded via the web interface of the amplifier, from the [[ENA_Configuration_-_AlphaCom_mode#Station_Administration_tab|Station Administration > Reboot]] menu
*[[ELTSI-1|ELTSI-1 Line End Transponder ]]
+
*Factory Reset Button: Insert a straightened paper clip or similar device into the hole - Wait 7 seconds after power-on, then push for 1 second and release.
 +
 
 +
==Accessories==
 +
 
 +
*[[ENA2100-AC_Amplifier_-_Mounting_and_Installation#Mounting|Mounting Kits for single or double amplifiers in 19" rack]]
 +
*[[ELTSI-1|ELTSI-1 Line End Transponder]]
  
== Related Information ==
+
==Related Information==
* [https://www.zenitel.com/product/ena2400-AC Additional Documentation on Zenitel.com]
 
  
[[Category: Public Address - Network amplifiers]]
+
*[https://www.zenitel.com/product/ena2100-AC Additional Documentation on Zenitel.com]

Latest revision as of 11:36, 27 June 2024

Obsolete icon This product is discontinued!


Note icon This product is replaced by the ENA2100-AC2 Amplifier


AIS.png
ENA2100-AC amplifier (1023102100)

The ENA2100-AC Amplifier is a 2 x 100 watt IP based amplifier that can register to the AlphaCom server over an IP network.

The ENA2100-AC amplifier operates from a 115/230 VAC supply and is designed to survive minor interruptions to the power supply.

The amplifier has two separate loudspeaker channels. Each channel can be addressed separately, i.e. belong to two different zones, or the two channels can be combined into one channel.

The amplifier monitors the speaker lines for shorts, overload and opens. A Line End Transponder (ELTSI) can be used for reliable detection of an open line. More than one ELTSI can be connected to the same line, allowing monitoring of several branches on the speaker line. The amplifier also monitors control inputs, power, temperature, network connections and every other component required for operation of essential services. Faults will be indicated locally on the amplifier and the fault relay, as well as reported to the AlphaCom server which can raise an event or forward the reports to syslog, SNMP and internal log.

The amplifier’s control inputs/outputs and audio inputs can be used locally by the amplifier (e.g. for PTT and audio from a handheld microphone) or can be controlled by the system (e.g. audio input for background music).

Installation, Indicators and Dimensions

Configuration

AlphaCom mode

SIP mode

Common Configuration

Software Upgrade and Restore Factory Defaults

The ENA amplifier is a "Turbine" device, and the software is upgraded in the same way as Turbine Intercom stations.

Load Factory Default values:

  • Factory Default values can be loaded via the web interface of the amplifier, from the Station Administration > Reboot menu
  • Factory Reset Button: Insert a straightened paper clip or similar device into the hole - Wait 7 seconds after power-on, then push for 1 second and release.

Accessories

Related Information