This article describes the configuration required for a Exigo Network Amplifier (ENA) to operate with an AlphaCom server. The ENA Amplifiers are configured through their web interface. The AlphaCom server is configured using the PC tool AlphaPro.

Quick getting started guide

To make an ENA Amplifier operational with an AlphaCom server, the minimum configuration is four parameters to set in the web interface of the amplifier. Log In to the amplifier, go to Station Main > Main Settings, and:

  1. Set Station Mode = "Use AlphaCom"
  2. Configure the IP Settings (IP address) of the amplifier
  3. Enter the AlphaCom IP-address
  4. Enter Ch1 Out Directory Number


The Directory Number must also be defined in the AlphaCom Server using the AlphaPro configuration tool.

The amplifier web interface

Station Main tab

Station Information

  • Log In to the amplifier
  • The Station Information page will now be displayed, showing the amplifier configuration and status.
The Station Information page


Note icon {{{1}}}


To find the IP address of the amplifier, use the Menu Selection Knob on the front of the amplifier, and navigate to Information > Network.


Main Settings

  • Click Station Main > Main Settings to access the page for configuring Station Mode and IP parameters.
ENA MainSettings.PNG


Station Mode: Select the Use Alphacom radio-button.

Registration Settings:

  • AlphaCom IP-address: Enter the IP address of the AlphaCom server to which the amplifier is to be registered

The amplifier can be assigned up to three separate directory numbers: Channel 1, Channel 2 and Audio Input. The directory number(s) must also be defined in the AlphaCom server.

  • CH1 Out Directory Number: The first registered channel. This channel only supports audio output to CH1 amplifier.
  • CH2 Out Directory Number: The second registered channel. This channel will output audio to CH2 amplifier.
    • Disabled option will disable this channel registration
    • Mirror CH1 audio will play CH1 audio stream on CH2, and CH2 will not require directory number and will not use any license
    • When channel is mirrored, channel monitoring and volume controls (in web and GUI) are still separate
  • Audio In Directory Number: The third registered channel. This channel is used to send mic or line in audio to the AlphaCom
    • Disabled option will disable this channel registration

IP Settings:

  • DHCP – Select this option if the IP station shall receive IP Settings from a DHCP server.
  • Static IP – Select this option if the IP station shall use a static IP address. Enter values for:
- IP-address
- Subnet-mask
- Gateway
- DNS Server 1 (option for network administration)
- DNS Server 2 (option for network administration)
- Hostname (option for network administration)
  • Disable Reset to Factory default settings using frontboard and I/O: If enabled, factory reset will only be possible from the web interface. This is disabled by default.
  • Read IP Address: Not in use
  • Enable RSTP: RSTP is only required when using redundant networking

Click Save followed by Apply to apply the new configuration settings.

Station Administration tab

Reboot

  • Reboot system: Perform a full Linux reboot. No configuration is lost
  • Reboot main application: Perform a restart of the intercom application. No configuration is lost
  • Factory reset: Set all parameters to Factory Default values. The amplifier will get static IP Address 169.254.1.100.
  • Factory reset with DHCP: Set all parameters to Factory Default values. The amplifier will get IP Address from DHCP server. If no DHCP server in the network, it will get a random 169.254.x.x IP address.
  • Clear local ZAP profile: For special purpose
  • Delete ZAP data.lua: For special purpose

Logging

From the web interface of the amplifier it is possible to activate logging, which can be useful for debugging and troubleshooting purposes. See Logging - IP Stations for more information.

Change Password

The password for web access can be changed, see Password (IP Stations).

Backup and Restore

From the web interface of the amplifier it is possible to backup and restore the configuration data. See Backup and Restore for more information.

Manual Upgrade

The software of the amplifier can be upgraded via the web interface. see Turbine_Software_Upgrade for details.

Advanced AlphaCom tab

Audio

In Advanced Alphacom > Audio Dynamic Range Compression can be enabled.

ENA DynRangeComp.PNG


Time Settings

  • Select Advanced AlphaCom > Time Settings from the menu
Turbine config 5.PNG


Time Settings: You can enable Network Time Protocol, select the time zone and set the hostname or the IP address of the NTP server.

Advanced Network tab

SNMP

A set of SNMP functions are available in the IP station. SNMP (Simple Network Management Protocol) is a protocol for centralizing the management of devices in IP networks.

See SNMP Settings for futher information.

802.1X

IEEE 802.1X is an IEEE Standard for port-based Network Access Control (PNAC). It provides an authentication mechanism to devices wishing to attach to a LAN, either establishing a point-to-point connection or preventing it if authentication fails. For details on configuration, see IEEE 802.1X.

Firewall

All IP Stations have an embedded firewall. See Firewall for details.

Monitoring and Lines

Status

The Status page


  • Faults
    • Display currently active faults on amplifier
    • The page is automatically refreshed each 10 seconds (can be manually refreshed)
    • Only faults that are active for enabled monitoring options are visible
    • If the page is empty there are no reported faults
  • Temperature measurements
    • Display different temperature levels
  • Voltage measurements
    • Display measured voltage levels for diagnostics

Line Control

The Line Control page


Voltage options:

  • Line Voltage choose speaker line voltage from 70V or 100V options
  • Voltage is saved independently

Channel 1/Channel 2 options:

  • Channel Enabled will disable/enable selected channel, this shutdowns/starts channel amplifier and is not related to disabling channel registration (Station Main → Main Settings → Registration Settings → CH2/Audio in → Disabled)
  • Master Volume in dB changes channel volume for digital audio
  • Analog Route Line In to ch - (only available when ln1 → Line In Type is Line Input) will analog route line in audio to channel output - this is HW Bypass
    • On ENA2 hardware when enabled this option will disable digital audio playback (from IP) and has to be selected for both channels simultaneously
      • Routing starts working when device boots
  • Analog Routing Gain (only available when Analog Route Line In to ch is enabled) in dB offers setting gain when analog routing is selected, Master Volume values are not used. Setting goes from -6 to 0dB.
  • Monitor Mode can be Disabled, Manual for manual monitor triggering and Continuous for continuous monitoring
    • To get access to monitoring configuration options, either type of monitoring has to be enabled

Line In options:

  • Line In Type selects which input is used for audio input: Line in or Microphone
  • Impedance changes line in impedance
  • Gain changes line in gain
  • Phantom Microphone (only available when Line In Type is Microphone Input) enables phantom power for microphone


Available monitoring options when Monitoring is set to Continuous or Manual:

Channel 1/Channel 2:

  • LET Monitoring enables Line End Transponder monitoring
  • Line Monitoring enables Speaker Line Monitoring (SLM)
  • Line Monitoring Options (only available when Line Monitoring is enabled)
    • Detailed Line Fault Reporting will enable separate reporting of open and shorted, not available on all speaker line configurations
    • Load Change monitor line load change
    • Ground Fault monitor line ground fault
  • Manual Monitoring Options (only available when Monitor Mode is Manual)
    • Remove LET Faults when enabled LET faults will be removed when manual monitoring is finished
    • Remove SLM Faults when enabled SLM faults will be removed when manual monitoring is finished
  • Fault Report Options
    • Report Faults Severity selects how are line faults reported on device GUI as critical (red exclamation sign) or warnings (yellow exclamation sign)
  • Suspend Monitoring Options (only available when Monitor Mode is Continuous)
    • When Suspended Monitoring is enabled, the amplifier will suspend the monitoring signal when there is a call on the channel to avoid false alerts and maintain audio quality.
  • LET (only available when LET Monitoring is enabled)
    • 10 LETs per channel can be added
    • Failed Counter How many times LET should fail before error is reported
  • Calibration Info (only available when channel monitoring is enabled, configured and saved)
    • Calibrate command (35 seconds timeout) will attempt channel calibration
    • Reset Calibration (3 seconds timeout) will reset channel calibration
    • Measure (60 second timeout, only available if Monitor Mode is Manual and channel is successfully calibrated) will manual monitor channel for 60 seconds and report any faults detected

Line In:

  • Pilot Tone Sensing (only available when Advanced Alphacom → Lines → ln1 → Line In Type is Line Input)
  • Phantom Microphone Monitoring (only available when Advanced Alphacom → Lines → ln1 → Line In Type is Microphone Input and Phantom Microphone is enabled)
    • When enabled, a fault is reported when a phantom powered microphone is disconnected. Default values are tested to work well detecting an ECM3000 phantom powered microphone.
  • Current Connected Minimum (only available when Phantom Microphone Monitoring is enabled). Sets the minimum amount of current in microamperes passing through the microphone connection before the alert is triggered.
  • Voltage Connected Minimum (only available when Phantom Microphone Monitoring is enabled).

RCO/RCI Config

Advanced Config

Configuration of the AlphaCom server

AlphaPro configuration

The amplifier is defined in Users & Stations window, General tab. For minimum configuration you need to enter these fields:

  • Directory Number - must match the directory number configured in the amplifier itself
  • Display Text - Any free text. Used as Caller ID.
  • Station Type - Set to Substation
  • CCoIP Station - Tick this checkbox
  • Reg. w/Directory Number - Tick this checkbox
Users & Stations window


AlphaWeb configuration

Filter settings

Log on to the web interface of the AlphaCom server, and select System Configuration > Filters.

Enable "IP Stations" on TCP port 50001 and "VoIP Audio" on UDP ports 61000-61150 on the ethernet port used for the IP stations. By default these ports are enabled on ethernet port 1.

Enable ports for IP Stations


Licenses

The amplifier require licenses