Actions

IP-LCM

From Zenitel Wiki

Revision as of 10:26, 20 June 2024 by Asle (talk | contribs) (IP-LCM hardware versions)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
AEIPS.png

The IP-LCM module is an expansion to the TKIS-2, and adds high power relays and robust control inputs to the kit without extra wiring.

DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems.

IP-LCM v1.1.png
IP Line Connection Module (1008095201)

The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems.

  • 8 relay outputs
  • 8 control inputs
  • Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG
  • Device powered via the TKIS-2 kit using PoE or local power
  • All TKIS-2 features are available in addition, including:
    • 1 relay
    • 6 I/Os
    • Analog 0dB Line Out
    • Analog 0dB Line In (as from hardware version 1008131020.0200)

In general Zenitel offers a number of IP based kits, which can be used for a wide range of applications. See the kit comparison chart.

License Requirements


Even if only the I/O part (no audio) of the IP-LCM is used a license is required.

IP-LCM hardware versions

There are two hardware versions:

  • Version 1008131020.01xx: Original version
  • Version 1008131020.0200: Added support for analog Line In

Hardware version 1008131020.0200 can be visually identified by:

    • The TKIS-2 kit assembled with the text in same orientation as circuit board text
    • Zenitel logo with V1.1 print
    • Line-in connector - J104
    • Item number ending with .0200

Getting started

Configuration

General configuration:

Device specific configuration for the IP-LCM:

Restore Factory Defaults and Software Upgrade

Connectors, Indicators and Dimensions

Software Requirements

The IP-LCM is fully supported from device version 4.11.x.x

When used in AlphaCom mode, this device is fully supported as from AlphaCom version 11.2.3.7

Related Information