Line 1: Line 1:
{{APS}}[[File:IP-LCM 1.jpg|thumb|350px|IP Line Connection Module ( 1008095201)]]
+
{{AEIPS}}
 +
The '''IP-LCM module''' is an expansion to the [[TKIS-2]], and adds high power relays and robust control inputs to the kit without extra wiring.
  
The IP-LCM module is an expansion to the TKIS-2 that adds high power relays and robust control inputs to the kit without extra wiring. <br/>
+
DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems.
DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems. <br/>
+
<table style="float:right; max-width:80%; border-style: double; border-color: #c7c7c7;">
The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems.<br/>
+
<tr style="rowspan:2;">
 +
<td style="display: block; vertical-align: bottom;">[[Image:IP-LCM v1.1.png|500px]]</td>
 +
</tr>
 +
<tr>
 +
<td style='background-color:#efefef;'>IP Line Connection Module (1008095201)</td>
 +
</tr>
 +
</table>
  
 +
The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems.
 
* 8 relay outputs
 
* 8 relay outputs
 
* 8 control inputs
 
* 8 control inputs
 
* Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG
 
* Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG
 
* Device powered via the TKIS-2 kit using PoE or local power
 
* Device powered via the TKIS-2 kit using PoE or local power
* All TKIS-2 features available
+
* All [[TKIS-2]] features are available, including:
Exigo and AlphaCom are supported.
+
** 1 relay
 +
** 6 inputs
 +
** 0dB Line Out
 +
* As from HW version 1.1 there is also 0dB Line In available.
  
== Getting started ==
+
In general Zenitel offers a number of IP based kits, which can be used for a wide range of applications. See the [[Kits - Comparison chart|kit comparison chart]].
* [[IP-LCM Connections|Connections]]
+
 
 +
==License Requirements==
 +
 
 +
* An [[Licenses_for_ICX-500_and_ICX-AlphaCom_Core#Available_licenses|IP Station License is required for ICX-AlphaCom]].
 +
* An [[Licenses#IP_station_license|IP Station License is required in the AlphaCom]].
 +
 
 +
 
 +
Even if only the I/O part of the IP-LCM is used a license is required.
 +
 
 +
==Getting started==
 
* [[Starting Up Turbine Station|Starting up]]
 
* [[Starting Up Turbine Station|Starting up]]
  
== Configuration ==
+
==Configuration==
The IP-LCM is configured in the same way as for the Turbine in general.
+
General configuration:
[[Turbine Configuration - AlphaCom mode|Turbien configuration]] <br>
+
 
The control inputs on the IP-LCM module is configured to RCI 17-24.<br>
+
* [[IP Station Configuration - ICX-AlphaCom mode|ICX-AlphaCom mode]]
The control outputs are mapped to pins 17-24.
+
* [[Adding station to existing system (Edge)|Edge mode]]
 +
* [[SIP Intercom - Web Interface|SIP mode]]
 +
 
 +
Device specific configuration for the IP-LCM:
 +
 
 +
*[[IP-LCM Configuration (ICX-AlphaCom)|ICX-AlphaCom mode]]
 +
*[[Relay_Settings_(Edge)#Operating the relay of a Remote Device|Edge mode]]
 +
*[[Relay_Settings_(SIP)|SIP mode]]
 +
 
 +
==Restore Factory Defaults and Software Upgrade==
  
== Restore Factory Defaults and Software Upgrade ==
+
*[[TKIS Restore Factory Defaults|Restore Factory Defaults]]
* [[TKIS Restore Factory Defaults|Restore Factory Defaults]]
+
*[[Turbine Software Upgrade|Upgrade via the station web interface]]
* [[Turbine Software Upgrade|Upgrade via the station web interface]]
+
*[[IMT - Discover & Upgrade|Upgrade using the IMT tool]]
 +
* [[:Category:IMX28 Release notes|Software Release Notes]]
  
== Connectors, Indicators and Dimensions ==
+
==Connectors, Indicators and Dimensions==
* [[IP-LCM Compact Board Connectors|Board Connections]]
+
* [[IP-LCM Connections|Device Connections]]
* [[IP-LCM Indication LEDs|IP-LCM Indication LEDs]]
 
 
* [[IP-LCM Dimensions & Mounting Instructions|Dimensions]]
 
* [[IP-LCM Dimensions & Mounting Instructions|Dimensions]]
  
== Additional Documentation on Zenitel.com ==
+
==Software Requirements==
* [http://www.zenitel.com/product/ip-lcm Additional Documentation on Zenitel.com]
+
The IP-LCM is fully supported from device version 4.11.x.x
 +
 
 +
When used in AlphaCom mode, this device is fully supported as from AlphaCom version 11.2.3.7
 +
 
 +
==Related Information==
 +
*[[VoIP kit as PA Interface]]
 +
*[http://www.zenitel.com/product/ip-lcm Additional Documentation on Zenitel.com]
 +
 
  
[[Category:Additional equipment]]
+
[[Category: Turbine]]
[[Category:Public Address - Interfaces]]
+
[[Category: Additional equipment]]
 +
[[Category: Public Address - Interfaces]]

Latest revision as of 14:47, 22 April 2024

AEIPS.png

The IP-LCM module is an expansion to the TKIS-2, and adds high power relays and robust control inputs to the kit without extra wiring.

DIN-rail mounting allows for a flexible I/O device that reduces the amount of wiring for I/O inside racks and other systems.

IP-LCM v1.1.png
IP Line Connection Module (1008095201)

The large robust connectors allow for connections to external cabling without adding extra terminals and have been especially chosen to enable quick and easy connection of such systems.

  • 8 relay outputs
  • 8 control inputs
  • Robust push-in connectors for cables up to 1.5 mm2 / 16 AWG
  • Device powered via the TKIS-2 kit using PoE or local power
  • All TKIS-2 features are available, including:
    • 1 relay
    • 6 inputs
    • 0dB Line Out
  • As from HW version 1.1 there is also 0dB Line In available.

In general Zenitel offers a number of IP based kits, which can be used for a wide range of applications. See the kit comparison chart.

License Requirements


Even if only the I/O part of the IP-LCM is used a license is required.

Getting started

Configuration

General configuration:

Device specific configuration for the IP-LCM:

Restore Factory Defaults and Software Upgrade

Connectors, Indicators and Dimensions

Software Requirements

The IP-LCM is fully supported from device version 4.11.x.x

When used in AlphaCom mode, this device is fully supported as from AlphaCom version 11.2.3.7