=== Create events ===
+
=== Events ===
 +
 
 +
==== Create Generic Events ====
 
[[Image:Milestone Add new event.png|thumb|A event which is triggered when receiving the string "Cam101" from the AlphaCom]]
 
[[Image:Milestone Add new event.png|thumb|A event which is triggered when receiving the string "Cam101" from the AlphaCom]]
 
We want to use EDO strings from the AlphaCom to control the pictures in the monitor. When a string sent from the AlphaCom is recognized by the Milestone, we want the correct camera to show up in the monitor. We need to decide what string to use for each camera. Here is a suggestion:
 
We want to use EDO strings from the AlphaCom to control the pictures in the monitor. When a string sent from the AlphaCom is recognized by the Milestone, we want the correct camera to show up in the monitor. We need to decide what string to use for each camera. Here is a suggestion:
Line 41: Line 43:
 
Create generic events in Milestone by selecting '''Administrator''' -> '''Generic Events''', and 'Add new event'. Add a new event for each camera.
 
Create generic events in Milestone by selecting '''Administrator''' -> '''Generic Events''', and 'Add new event'. Add a new event for each camera.
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
 +
==== Assosiate cameras with events ====
 +
In the Administrator window, highlight a camera and press "Settings", then "Event notifications".
  
 
==AlphaCom configuration==
 
==AlphaCom configuration==

Revision as of 16:09, 18 August 2009

Situation

When a master station is receiving Call Requests from a substation, an event can be activated to control the Milestone IP Video surveillance system. Using the AlphaCom's EDO port the system allows for a few simple events to control cameras located in association with a station. When scrolling the queue, the event handler transmits commands related to the selected station. In this way the picture on the monitor will follow the queue navigation on the master station.

If any new call requests are received while in conversation, this will not influence on the active image. When the conversation is cancelled, and there are still calls in the queue, the image assosiated to the first station in queue will be displayed.


Configuration of Milestone XProtect

Matrix function

Matrix configuration on server

It is assumed that a Milestone XProtect system is already up and running, with some cameras defined and a Smart Client for picture viewing.

The Matrix configuration is required in order to have live images automatically presented on the required monitor when defined events occur. The Matrix function allows distributed viewing of live video from any camera on any monitor on a network operating with XProtect Professional. A computer on which Matrix-triggered video can be displayed is known as a Matrix recipient. Being able to view Matrix-triggered video requires that either a Smart Client or the dedicated Matrix Monitor software is installed on the user’s computer.

In the Administrator window select the Matrix button. The Config tab lets you define individual computers on which it should be possible to view Matrix-triggered content. Enable 'Milestone XProtect Matrix', and enter name, IP address of the matrix recepient, the port number (default 12345) and a password.

Smart Client setup as Matrix recepient

To make the Smart Client work as a matrix recepient, start the Smart Client application and select the tab Setup. In the System Overview selection drag the Matrix icon over to the main window. While the main window is in focus, click the button Connection Settings in the Properties selection, and enter port numer 12345 and the same password as you entered in the Matrix setup in the Administrator program.

Events

Create Generic Events

A event which is triggered when receiving the string "Cam101" from the AlphaCom

We want to use EDO strings from the AlphaCom to control the pictures in the monitor. When a string sent from the AlphaCom is recognized by the Milestone, we want the correct camera to show up in the monitor. We need to decide what string to use for each camera. Here is a suggestion:

EDO string/Event message Camera Event name Station dir.no
Cam101 Entrance EntranceEvent 101
Cam102 Backdoor BackdoorEvent 102
Cam103 Corridor CorridorEvent 103

Create generic events in Milestone by selecting Administrator -> Generic Events, and 'Add new event'. Add a new event for each camera.

Assosiate cameras with events

In the Administrator window, highlight a camera and press "Settings", then "Event notifications".

AlphaCom configuration

The master station should use the 763x codes for queue navigation. These directory numbers should be assigned to DAK keys. A number of station types can be used for call queuing. The station should be prepared for call queue operation, how to do this depends on the station type used:

Communication setup

EDO setup

EDO setup. Select 'TCP/IP Client' mode, and specify the IP Address of the Milestone server, and the TCP port number

The MileStone XProtect is by default using TCP port 1234 for generic events. If required this port number can be modified from Milestone XProtect Administrator, I/O Setup -> Advanced -> Alert port.

From AlphaPro, Exchange & System -> Serial Ports, the EDO port must be configured to communiate with the computer running the Milestone XProtect server.


TCP/IP disconnection after data is sent

Event which causes TCP disconnection on EDO port 1 after transmission

The Milestone XProtect server requires that the TCP/IP connection is disconnected after every transmission. The AlphaCom has an option to tear down the TCP connection after data is sent. To set this option an event must be used which writes to the relevant parameter into the AMC-IP memory at exchange startup. Create an event 27, subevent 65, When Change To: ON, Action: $SNV Q48 W5 W3 W6 W1 W0 W6 W4.

Include all substations with cameras in UDP group 2.

The Event Handler is used to transmit commands through the EDO port to the Milestone IP Video system.

A UDD is used to store the conversation status of the master station. 0 = no conversation, 1 = conversation. The index of the UDD is equal to the physical nymber of the master station. The UDD is checked when call requests are received or deleted. If there is a conversation active no commands should be transmitted. In addition UDD 600 is set if there is any priority mails in the queue at all.


In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events:


Event 1 - When a conversation is made from the master station to the substation, set the conversation status in the UDD, and transmit camera commands to the IP Video system. Also check if the camera is not already active due to other events.

Event Owner: The Master Station (or a UDP group of master stations)
Event type: 08 - Conversation Outgoing
Subevent: 0
When change to: ON or OFF
When related to: Stations w. UDP, Id: 2
Action: WUDD %1.phy 1
  IF %udd(%2.phy)
  STOP
  ENDIF
  EDO 1 "cam %2.phy on"

Event 2 - When the conversation between the master and substation cancels, reset the conversation status (UDD), switch off the camera, and activate the MAILQ_NAVIG command. This command will step to the first in the queue, and re-trigger the '23 - New Current Mail' event.

Event Owner: The Master Station (or a UDP group of master stations)
Event type: 08 - Conversation Outgoing
Subevent: 0
When change to: OFF
When related to: Stations w. UDP: Id 2
Action: WUDD %1.phy 0
  WUDD %2.phy 0
  $MAILQ_NAVIG L%1.dir 2
  EDO 1 "cam off"

Event 3 - When receiving a Call Request or scrolling the queue, and the master station is not in conversation, activate the camera assosiated with the selected substation. Also set a UDD for the substation with the active camera.

Event Owner: The Master Station (or a UDP group of master stations)
Event type: 23 - New Current Mail
Subevent: 0
When change to: ON
When related to: Stations w. UDP, Id: 2
Action: IF %udd(%1.phy)
  STOP
  ENDIF
  EDO 1 "cam %2.phy on"
  WUDD %2.phy 1

Event 4 - When a queue entry is deleted or scrolled away from, and the master station is not in conversation, switch off the camera:

Event Owner: The Master Station (or a UDP group of master stations)
Event type: 23 - New Current Mail
Subevent: 0
When change to: OFF
When related to: Stations w. UDP, Id: 2
Action: IF %udd(%1.phy)
  STOP
  ENDIF
  IF %udd(%2.phy)
  STOP
  ENDIF
  EDO 1 "cam off"