  • ...utput''': 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver. These connections are used as relay contacts for door lock control and external I/O devices.
    2 KB (243 words) - 15:13, 10 May 2023
  • ...telecom world, the standard audio level is much higher, headroom as small as 3dB is normal. Therefore AlphaCom audio needs to be amplified when sent to Values: 0 (zero) means use default values as described above. Non-zero value: the specified value is used for the matchi
    3 KB (521 words) - 14:46, 5 February 2018
  • *'''Name:''' The name that will be shown on the display, and used as Caller ID. ...ly if the Edge Controller requires authentication and is normally the same as the Number (SIP ID).
    2 KB (322 words) - 17:01, 11 January 2024
  • ...| "owner" station reference for event 38-Group Dynamic Include event. Sent as response when including stations, sub events for faults. (Default LV = empt ...st be sent to all nodes involving the new members. Trick: Send the message as node broadcast.
    2 KB (274 words) - 11:02, 2 January 2024
  • ...general purpose audio interface which is used for multiple purposes, such as Audio Program feed, Station port with analog 0dB in/out, or communication b ...There can be up to 6 "AGA Stations" per AGA board. An AGA Station will act as a regular station, i.e. you can call it by its directory number, it can be
    5 KB (814 words) - 15:53, 2 May 2023
  • The value 0xF1 is used as a frame termination and as a EndOfTransmit message. This value cannot be present in the rest of the fr
    2 KB (319 words) - 14:54, 7 September 2017
  • ...ed the device to reboot without notifying the user. This is now fixed, and as in earlier software releases, the user is redirected to a new page with an === MTN-4181 Report DAK and Report station call events as Digital Input in ONVIF options are now working for Hanwha VMS===
    3 KB (484 words) - 10:06, 21 June 2024
  • * Use AlphaWeb to upload a wav-file as alarm message 3, dir no 8193 (wav file is found on the memory stick)
    570 bytes (82 words) - 12:43, 1 October 2013
  • |align=center|2||UINT(0..n)||colspan="3"|Search string as stored in AlphaCom<br />
    605 bytes (82 words) - 14:26, 6 July 2022
  • {{AS}}[[File:ENA2400-AC.png|thumb|alt=ENA2400-DC.|500px|ENA2400-AC amplifier]] ...y on the [[ENA User Interface|amplifier display]] and fault relay, as well as reported to the AlphaCom server which can raise an event or forward the rep
    3 KB (486 words) - 12:31, 27 June 2024
  • ...from the [[Audio Program|audio program inputs]] out via the FBSAR, as well as [[Voice Alarm Messages|alarm messages]] from the [[ASVP]] board. ...rt''' to create an event with the following parameters (here RCO 1 is used as an example):
    3 KB (428 words) - 11:01, 1 June 2022
  • *Outbound Proxy: Same as the Primary SIP Server *User ID: The Directory Number as configured in the ICX or IC-EDGE Controller
    3 KB (501 words) - 12:22, 23 February 2023
  • ...ecting over '''TCP port 502'''. It does not require a checksum calculation as lower layers already provide checksum protection. {{Note|'''Modbus TCP''' is not the same as Modbus over TCP/IP, which includes a checksum in the payload.}}
    8 KB (1,365 words) - 11:11, 4 December 2023
  • The audio to and from IP devices is transmitted as RTP over UDP. Audio encoding is G.722 or G.711 A- or u-law. The IP device i ICX-AlphaCom uses UDP ports from the same pool as AlphaNet and SIP (61000 - 62000) for audio to and from IP device.
    5 KB (776 words) - 15:44, 25 October 2023
  • ...way communication. The "HD Audio" option is intended for Turbine kits used as PA Interfaces''.}} === TKIE-2 as Audio Source===
    7 KB (1,160 words) - 15:10, 27 October 2023
  • ...col controlling wireless pagers. It uses ISO 1745, point-to-point on RS232 as data link layer. The AlphaCom can use this in two ways: Same message, written as hex-values:
    1 KB (219 words) - 10:36, 20 June 2018
  • ...ed the device to reboot without notifying the user. This is now fixed, and as in earlier software releases, the user is redirected to a new page with an === MTN-4181 Report DAK and Report station call events as Digital Input in ONVIF options are now working for Hanwha VMS===
    4 KB (547 words) - 10:19, 21 June 2024
  • {{AS}}[[File:ENA2400-DC.jpg|thumb|alt=ENA2400-DC.|500px|ENA2400-DC amplifier]] ...y on the [[ENA User Interface|amplifier display]] and fault relay, as well as reported to the AlphaCom server which can raise an event or forward the rep
    3 KB (496 words) - 12:30, 27 June 2024
  • ...the actual [http://en.wikipedia.org/wiki/Syslog syslog] protocol, as well as the application or library sending syslog messages.
    2 KB (296 words) - 09:38, 26 June 2024
  • ...ment Studio'''’ (freely available from Microsoft) to set the selected user as database owner, this is either: ...ection of the dialog, select '''db_owner''' and leave all other selections as they were
    2 KB (354 words) - 10:39, 29 June 2023

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)