Actions

Difference between revisions of "AlphaCom XE7"

From Zenitel Wiki

(Connections)
(Analogue Intercom Stations)
 
(108 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
[[Image:XE7.PNG|thumb|250px|AlphaCom XE7 Audio Server with HD Voice]]
 
[[Image:XE7.PNG|thumb|250px|AlphaCom XE7 Audio Server with HD Voice]]
  
=Highlights=
+
==Highlights==
 
* Made to provide critical communication in any environment
 
* Made to provide critical communication in any environment
* Supports 552 IP stations and 36 analog intercom stations
+
* Supports 552 stations, of which 36 stations can be analog intercom stations
 
* SIM card based software configuration and disaster recovery
 
* SIM card based software configuration and disaster recovery
 
* Fully compatible with any AlphaCom system
 
* Fully compatible with any AlphaCom system
  
=Mounting & Dimensions=
+
==Mounting & Dimensions==
The cabinet can be wall or shelf mounted or mounted in a 19” rack. It has room for installation of one AMC-IP processor board and up to 6 feature boards. The server also includes a power board and a cooling fan.  
+
The XE7 cabinet can be wall or shelf mounted, or mounted in a 19” rack. It has room for installation of one [[AMC-IP|AMC-IP processor board]] and up to 6 [[:category:Feature boards|feature boards]]. The server includes a power board and a cooling fan.  
  
[[File:XE7FrontView.PNG|300px|left|thumb|Front View]]
+
[[File:XE7 Dim.png|1200px|left|thumb|XE7 dimensions]]
<br style="clear:both;" />
 
[[File:XE7SideView.PNG|300px|left|thumb|Side View]]
 
<br style="clear:both;" />
 
[[File:XE7TopView.PNG|300px|left|thumb|Top View]]
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
=Board positions=
+
<br><br>
 +
 
 +
== Installation ==
 +
* Remove the front cover of the XE7 cabinet
 +
* Prepare the AMC-IP board with the STIC according to [[AMC-IP - AlphaCom Processor Board (Black)|this article]], then insert the AMC-IP board into board position 7.
 +
{{obs|
 +
* ''Turn '''power off''' before inserting or removing any boards''
 +
* ''Give the board a final firm push to make sure it goes all the way into position''.}}
 +
 
 +
* Insert the remaining feature boards ([[ASLT]], [[ATLB-12]] or [[AGA]] boards) in position 1 to 6. Normally you would start from board position 1 and upwards.
 
[[Image:XE7 backplane2.png|thumb|500px|left|Board positions and physical numbers in AlphaCom XE7]]
 
[[Image:XE7 backplane2.png|thumb|500px|left|Board positions and physical numbers in AlphaCom XE7]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
=Connections=
+
* Power up the XE7 server by connecting the output from the 24VAC transformer to the "24VAC In" connector.
[[File:XE7 backplane1.png|thumb|left|500px]]
+
** Alternatively connect a 24VDC power source to the "24VDC In" connector.
 +
* Watch the LEDs of the AMC-IP board. The system uses approx. 70 seconds to start up. When running the green status LED of the AMC-IP board should be flashing.
 +
* Connect a laptop to Eth 0 port, open a web browser (e.g. Firefox or Chrome), and log on to the embedded web server using IP address 169.254.1.5. (Default Username/Password = admin/alphaadmin)
 +
* [[AMC-IP software upgrade (Black AMC-IP board)|Upgrade the software]] of the server to the latest version. Upgrade is done from the web interface of the server. This will ensure that the system has the latest features, bug fixes and security updates.
 +
* Replace the front cover of the XE7 cabinet
 +
 
 +
<br> <br>
 +
 
 +
== Configuration==
 +
* [[AlphaPro]] is the Windows application used for configuring the AlphaCom XE system. Configuration of user data, such as Directory Numbers, Direct Access Keys, Group Calls etc. is done from AlphaPro.
 +
* [[AlphaWeb]] is the embedded web server running on AlphaCom XE. The AlphaWeb server provides functions for system monitoring, system configuration, and system upgrade. Initial connection is done by connecting a laptop to Eth 0 port, open a web broswer (e.g. Firefox or Chrome), and log on to the web server using IP address 169.254.1.5. (Default Username/Password = admin/alphaadmin).
 +
 
 +
<br><br>
 +
 
 +
==Connection details==
 +
[[File:XE7 backplane1.png|thumb|left|500px|Connections on the XE7 backplane]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
 
===Power===
 
===Power===
 
The server is normally powered from the mains via a 24VAC transformer. Battery backup power can be connected to the 24VDC input plug.
 
The server is normally powered from the mains via a 24VAC transformer. Battery backup power can be connected to the 24VDC input plug.
 +
{{note|For redundancy purposes it possible to connect both the 24VAC and the 24VDC at the same time. Under normal operation the server will use the 24VAC source. If the 24VAC drops out, the server will switch without any interruptions to the 24VDC source. }}
  
 
===Network===
 
===Network===
Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming
+
The XE7 server has two RJ-45 ethernet ports for IP communication. Ethernet port 0 (Eth 0) is by default configured as a Management port, allowing connection to the embedded web server ([[AlphaWeb]]) and connection of the PC configuration tool [[AlphaPro]].
 +
Default IP addresses:
 +
* Eth0 has IP address 169.254.1.5
 +
* Eth1 gets IP address from DHCP by default
  
 
===Analogue Intercom Stations===
 
===Analogue Intercom Stations===
All cables are terminated to connectors on the backplane. The two-pair star wired intercom cables and single-pair telephone cables are connected using pluggable screw connectors
+
There are [[Physical_number#AlphaCom_E7|36 physical ports]] for analog stations on the XE7 server. Station cables are terminated to these physical ports by means of [[Connection Kit ASLT/AGA/AE1/ATLB|plugable screw connectors]] on the backplane.
 
 
===Program Input===
 
[[Physical number 5 and 6 (AlphaCom E7)|Connectors 5 and 6]] on the first ASLT line board are enabled for program distribution. Additional programs can be connected by substituting line boards with AGA boards with 6 programs per board
 
  
===Remote Control Input (RCI)===
+
===Audio Program Inputs ===
There are two inputs for clean contacts on the [[RCI]] connectors which can execute programmable functions.  
+
[[Physical number 5 and 6 (AlphaCom E7)|Physical number 5 and 6]] on the first ASLT line board are by default enabled for [[Audio_Program#Audio_Programs_in_XE7|audio program distribution]]. If more program inputs are required, one can use the [[AGA|AGA board]] (6 programs per board), or use the [[Audio_Program#Audio_Programs_in_XE1|TKIE-2 kit as Audio Program interface]].
  
===Remote Control Outputs (RCO)===
+
If you want to use the physical ports 5 & 6 for regular analog stations instead, see article [[Physical number 5 and 6 (AlphaCom E7)]]
There are 12 RCOs that must be connected to optional [[MRBD]] relay boards, and can be programmed to execute functions such as door control.
 
  
 
===Serial Ports===
 
===Serial Ports===
The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
+
[[File:Serial ports XE1.PNG|thumb|right|400px|XE7 Serial ports pinout]]
 +
Serial ports can be used for communication with external equipment. There are two serial ports:
 +
* '''Serial Port 0''': R232 on an 9-Pin D-sub connector
 +
* '''Serial Port 1''': RS232, RS422 or RS485 on an RJ45 connector:
 +
** '''RS232:''':  [[AMC-IP_-_AlphaCom_Processor_Board_(Black)#Switches_and_Jumpers|Switch 8 on S601]] on the AMC-IP board must be set to OFF (default).
 +
** '''RS422''': [[AMC-IP_-_AlphaCom_Processor_Board_(Black)#Switches_and_Jumpers|Switch 8 on S601]] on the AMC-IP board must be set to ON. Jumpers on backplane in '''RS422''' position.
 +
** '''RS485''': [[AMC-IP_-_AlphaCom_Processor_Board_(Black)#Switches_and_Jumpers|Switch 8 on S601]] on the AMC-IP board must be set to ON. Jumpers on backplane in '''RS485''' position.
  
[[File:XEsmallConnections.png|thumb|left|500px|XE1 IP and serial connections]]
 
<br style="clear:both;" />
 
  
====Serial Port 0====
 
9-Pin D-sub (RS232 Only)
 
:No additional settings necessary
 
  
====Serial Port 1====
+
[[File:422 485 XE7.png|thumb|left|500px|Jumpers for RS422/485 selection for Serial Port 1 on the XE7 backplane]]
RJ45 (RS232/422/485)
+
<br style="clear:both;" />
:Additional settings:
 
:'''RS232:'''
 
:* [[AMC-IP_-_AlphaCom_Processor_Board_(Red)#Switches_and_jumpers|Switch 8 on S601]] on the AMC-IP board must be set to OFF.
 
  
:'''RS422/485:'''
+
<br><br>
:* [[AMC-IP_-_AlphaCom_Processor_Board_(Red)#Switches_and_jumpers|Switch 8 on S601]] on the AMC-IP board must be set to ON.
 
:* Use the two jumpers on the backplane to select between RS422 and RS485
 
[[File:SerialPortJumpers XE7.png|thumb|left|500px|RS422/485 selector for Serial Port 1 on the XE7 backplane]]
 
<br style="clear:both;" />
 
  
 
===Remote Control Inputs (RCI)===
 
===Remote Control Inputs (RCI)===
* There are two inputs for clean contacts on the [[RCI - Remote Contol Input|RCI connectors]] which can execute programmable functions.  
+
There are two remote control inputs available at the backplane of the XE7 server, called RCI 1 and RCI 2. The inputs are triggered by dry contacts. What actions to trigger when an input is activated is configured from AlphaPro in the [[Exchange_%26_System_(AlphaPro)#RCI|RCI table]]. For more information on usage and configuration, see [[RCI - Remote Contol Input]].
 
[[File:RCI XE7.png|left|thumb|500px|RCI inputs in an AlphaCom XE7]]
 
[[File:RCI XE7.png|left|thumb|500px|RCI inputs in an AlphaCom XE7]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
=Factory Reset (coldstart)=
+
<br><br>
Performing a '''cold start''' of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.
+
 
 +
===Remote Control Outputs (RCO)===
 +
There are 12 Remote Control Outputs (RCO) available from the XE7 server.
 +
* RCO 1 to 6 are operated by the [[ASLT]] or [[ATLB-12]] board in board postion 1
 +
* RCO 7 to 12 are operated by the ASLT or ATLB-12 board in board postion 2
 +
 
 +
The outputs are designed to drive the relays on a [[MRBD]] relay board.
  
[[File:AMC-IP ColdStartButton.png|thumb|left|200px|Cold start button on AMC-IP board]]
+
{{note|When the [[ATLB-12]] board is used, there will be [[ATLB in AlphaCom E7 - RCO's|only four RCOs]] available (not six) }}
 +
 
 +
Connection of MRBD Relay Board:
 +
[[File:RCOinXE7.png|thumb|left|300px|MRBD board connected to RCO 1-6]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
===Cold start procedure===
+
The operation of the outputs are configured in the [[Event Handler]]. By default the outputs from the XE7 server are mapped to logical RCO number 1 - 12, and are controlled by the [[RCO - Set Remote Control Output|RCO command]].
[[Image:Cold Start of AMC-IP.jpg|right|200px|thumb|Cold start to load default factory settings]]
+
 
*Press the reset button on the power card briefly while keeping the cold start button pressed.
+
Here are some examples:
*Keep the cold start button pressed at least 2 sec. after power on. The AMC status LED will blink green when the boot is ready.
+
* [[1-4h. Door Opening, Code Lock (practice)|Door opening and Code lock]]
 +
* [[2-2a. Call indication - Event Handler (practice)|Call indication]]
 +
 
 +
==Factory Reset (coldstart)==
 +
[[File:AMC-IP ColdStartButton.png|thumb|left|300px|Cold start button on AMC-IP board]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
=== Cold-start of AMC application only, keep IP setting ===
+
===Cold start procedure===
[[Image:Cold Start of AMC-IP.2.jpg|right|200px|thumb|Cold-start of AMC application]]
+
This procedure will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.
*Press the reset button on the power card briefly.
+
* Press and hold the cold start button of the AMC-IP board
*After 10 seconds, press the cold start button on the AMC-IP board.
+
* Press the reset button on the power card briefly
*Keep the cold start button pressed until the AMC status LED is blinking green.
+
* Keep the cold start button pressed for at least 2 seconds more. The status LED of the AMC-IP board will flash green when the system is up and running.
<br style="clear:both;" />
 
  
===Modify Factory Default Settings===
+
=== Cold-start of intercom application only, keep the IP settings ===
After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the [[AlphaPro]] programming tool must be used.
+
* Press the reset button on the power card briefly.
 +
* After 10 seconds, press the "cold start" button on the AMC-IP board.
 +
* Keep the "cold start" button pressed until the AMC-IP status LED is flashing green.
  
 
===Other methods of factory default===
 
===Other methods of factory default===
Line 97: Line 125:
 
* '''From [[AlphaPro]]:''' Upload a default AlphaPro database to the exchange
 
* '''From [[AlphaPro]]:''' Upload a default AlphaPro database to the exchange
  
=Upgrade=
+
==Software upgrade==
===Software upgrade===
+
* It is highly recommended to [[AMC-IP software upgrade (Black AMC-IP board)|upgrade the software]] of the server to the latest version. Upgrade is done from the web interface of the server. This will ensure that the system has the latest features, bug fixes and security updates.
See [[AMC-IP software upgrade]]
 
 
 
===Hardware Upgrade===
 
See [[AlphaCom Exchange Upgrade]]
 
 
 
=[http://www.zenitel.com/product/alphacom-xe7 Additional Documentation on Zenitel.com]=
 
  
=Related article=
+
==Related articles==
 
* [[Physical number 5 and 6 (AlphaCom E7)|Physical number 5 and 6]]
 
* [[Physical number 5 and 6 (AlphaCom E7)|Physical number 5 and 6]]
 +
* [http://www.zenitel.com/product/alphacom-xe7 Additional Documentation on Zenitel.com]
  
 
[[Category:AlphaCom Servers]]
 
[[Category:AlphaCom Servers]]

Latest revision as of 17:43, 4 March 2019

AlphaCom XE7 Audio Server with HD Voice

Highlights

  • Made to provide critical communication in any environment
  • Supports 552 stations, of which 36 stations can be analog intercom stations
  • SIM card based software configuration and disaster recovery
  • Fully compatible with any AlphaCom system

Mounting & Dimensions

The XE7 cabinet can be wall or shelf mounted, or mounted in a 19” rack. It has room for installation of one AMC-IP processor board and up to 6 feature boards. The server includes a power board and a cooling fan.

XE7 dimensions




Installation

  • Remove the front cover of the XE7 cabinet
  • Prepare the AMC-IP board with the STIC according to this article, then insert the AMC-IP board into board position 7.
OBS icon
  • Turn power off before inserting or removing any boards
  • Give the board a final firm push to make sure it goes all the way into position.


  • Insert the remaining feature boards (ASLT, ATLB-12 or AGA boards) in position 1 to 6. Normally you would start from board position 1 and upwards.
Board positions and physical numbers in AlphaCom XE7


  • Power up the XE7 server by connecting the output from the 24VAC transformer to the "24VAC In" connector.
    • Alternatively connect a 24VDC power source to the "24VDC In" connector.
  • Watch the LEDs of the AMC-IP board. The system uses approx. 70 seconds to start up. When running the green status LED of the AMC-IP board should be flashing.
  • Connect a laptop to Eth 0 port, open a web browser (e.g. Firefox or Chrome), and log on to the embedded web server using IP address 169.254.1.5. (Default Username/Password = admin/alphaadmin)
  • Upgrade the software of the server to the latest version. Upgrade is done from the web interface of the server. This will ensure that the system has the latest features, bug fixes and security updates.
  • Replace the front cover of the XE7 cabinet



Configuration

  • AlphaPro is the Windows application used for configuring the AlphaCom XE system. Configuration of user data, such as Directory Numbers, Direct Access Keys, Group Calls etc. is done from AlphaPro.
  • AlphaWeb is the embedded web server running on AlphaCom XE. The AlphaWeb server provides functions for system monitoring, system configuration, and system upgrade. Initial connection is done by connecting a laptop to Eth 0 port, open a web broswer (e.g. Firefox or Chrome), and log on to the web server using IP address 169.254.1.5. (Default Username/Password = admin/alphaadmin).



Connection details

Connections on the XE7 backplane


Power

The server is normally powered from the mains via a 24VAC transformer. Battery backup power can be connected to the 24VDC input plug.

Note icon For redundancy purposes it possible to connect both the 24VAC and the 24VDC at the same time. Under normal operation the server will use the 24VAC source. If the 24VAC drops out, the server will switch without any interruptions to the 24VDC source.


Network

The XE7 server has two RJ-45 ethernet ports for IP communication. Ethernet port 0 (Eth 0) is by default configured as a Management port, allowing connection to the embedded web server (AlphaWeb) and connection of the PC configuration tool AlphaPro. Default IP addresses:

  • Eth0 has IP address 169.254.1.5
  • Eth1 gets IP address from DHCP by default

Analogue Intercom Stations

There are 36 physical ports for analog stations on the XE7 server. Station cables are terminated to these physical ports by means of plugable screw connectors on the backplane.

Audio Program Inputs

Physical number 5 and 6 on the first ASLT line board are by default enabled for audio program distribution. If more program inputs are required, one can use the AGA board (6 programs per board), or use the TKIE-2 kit as Audio Program interface.

If you want to use the physical ports 5 & 6 for regular analog stations instead, see article Physical number 5 and 6 (AlphaCom E7)

Serial Ports

XE7 Serial ports pinout

Serial ports can be used for communication with external equipment. There are two serial ports:

  • Serial Port 0: R232 on an 9-Pin D-sub connector
  • Serial Port 1: RS232, RS422 or RS485 on an RJ45 connector:
    • RS232:: Switch 8 on S601 on the AMC-IP board must be set to OFF (default).
    • RS422: Switch 8 on S601 on the AMC-IP board must be set to ON. Jumpers on backplane in RS422 position.
    • RS485: Switch 8 on S601 on the AMC-IP board must be set to ON. Jumpers on backplane in RS485 position.


Jumpers for RS422/485 selection for Serial Port 1 on the XE7 backplane




Remote Control Inputs (RCI)

There are two remote control inputs available at the backplane of the XE7 server, called RCI 1 and RCI 2. The inputs are triggered by dry contacts. What actions to trigger when an input is activated is configured from AlphaPro in the RCI table. For more information on usage and configuration, see RCI - Remote Contol Input.

RCI inputs in an AlphaCom XE7




Remote Control Outputs (RCO)

There are 12 Remote Control Outputs (RCO) available from the XE7 server.

  • RCO 1 to 6 are operated by the ASLT or ATLB-12 board in board postion 1
  • RCO 7 to 12 are operated by the ASLT or ATLB-12 board in board postion 2

The outputs are designed to drive the relays on a MRBD relay board.

Note icon When the ATLB-12 board is used, there will be only four RCOs available (not six)


Connection of MRBD Relay Board:

MRBD board connected to RCO 1-6


The operation of the outputs are configured in the Event Handler. By default the outputs from the XE7 server are mapped to logical RCO number 1 - 12, and are controlled by the RCO command.

Here are some examples:

Factory Reset (coldstart)

Cold start button on AMC-IP board


Cold start procedure

This procedure will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.

  • Press and hold the cold start button of the AMC-IP board
  • Press the reset button on the power card briefly
  • Keep the cold start button pressed for at least 2 seconds more. The status LED of the AMC-IP board will flash green when the system is up and running.

Cold-start of intercom application only, keep the IP settings

  • Press the reset button on the power card briefly.
  • After 10 seconds, press the "cold start" button on the AMC-IP board.
  • Keep the "cold start" button pressed until the AMC-IP status LED is flashing green.

Other methods of factory default

A factory default can also be achieved in other ways:

  • From AlphaWeb: System Maintenance -> System Recovery -> Load Factory Defaults
  • From AlphaPro: Upload a default AlphaPro database to the exchange

Software upgrade

  • It is highly recommended to upgrade the software of the server to the latest version. Upgrade is done from the web interface of the server. This will ensure that the system has the latest features, bug fixes and security updates.

Related articles