Actions

Difference between revisions of "AlphaWeb"

From Zenitel Wiki

(High Availability)
(System Upgrade)
Line 288: Line 288:
  
 
==System Upgrade==
 
==System Upgrade==
[[Image:AW-AMCSystemStorageStatus.PNG|thumb|350px|AMC System Storage Status]]
+
[[Image:AW-SystemUpgradeInfoStatus11.PNG|thumb|350px|Package Info]]
[[Image:AW-PackageInfo.PNG|thumb|350px|Package Info]]
 
 
[[Image:AW-UploadFile.PNG|thumb|350px|Upload File]]
 
[[Image:AW-UploadFile.PNG|thumb|350px|Upload File]]
 
[[Image:AW-PackageInfo2.PNG|thumb|350px|Package Info after Uploading New File]]
 
[[Image:AW-PackageInfo2.PNG|thumb|350px|Package Info after Uploading New File]]

Revision as of 14:17, 1 March 2012

AlphaWeb - Monitoring and configuration interface

This article describes the web interface (AlphaWeb) of the AlphaCom XE series.

AlphaWeb XE is an embedded web server running on AlphaCom XE. It allows the users to log in using a standard web browser such as Internet Explorer or Firefox to operate and manage the AlphaCom XE system. The AlphaWeb server provides functions for system monitoring, system configuration, and system upgrade.

AlphaWeb Login

Connect the PC to Eth0, and enter 169.254.1.5 in the web browser
  • Connect the PC Ethernet port to the LAN port (Eth0) on the AlphaCom XE.
  • Open your web browser to access AlphaWeb.
    • The factory default IP address of the AlphaCom server is 169.254.1.5.
    • In order for your PC to communicate with the server, it is necessary to change its Internet Protocol Properties to use an IP address that is in the same range as 169.254.1.5.
  • Enter http://169.254.1.5 in the address field. The Login page should now appear.
The Login page

Press Login, and you will be prompted for a user name and password.

To log in as a user with reading rights only, do as follows:

  • Default user name: alpha
  • Default password: com

To be able to change the configuration, the user must log in as an administrator. The default login will then be:

  • User name: admin
  • Password: alphaadmin

A window with server configuration information will be displayed.

Changing Default User Name and Password

It is recommended to change the default user names and passwords for security reasons.

  • Select System Configuration > User Management
  • Enter the old passwords for both Read access and Read/Write access (defaults: com and alphaadmin)
  • Enter new user names and passwords
  • Re-enter the new passwords to confirm
  • Verify by clicking Update User 1 and Update User 2
  • Write down the selected passwords and keep them in a secure place.

Saving and Applying changes

When new configuration parameters are entered, they should be saved to the configuration file by clicking Save. The configuration data is then only saved to the AlphaCom configuration file and not applied to the running configuration. To get the new configuration data applied to the running configuration, click Apply.

System Monitoring

Node Information

Shows general information about the system such as Node Name and Node Number. It also shows state information; different times and memory usage. Information about the Software Configuration, and the Hardware Configuration (the different boards and versions), and also the state of the different processes running in the system.

Information

Node information
  • Node name: The name of the exchange, as per entered in AlphaPro, Exchange & System > System menu.
  • Node number: Default node number is 1. The node number is used for communication between exchanges connected in a network (AlphaNet). The node number can be changed from AlphaPro, Exchange & System > System menu.
  • Operational: Enabled: The intercom application (AMCd) is running. Disabled: The intercom application (AMCd) is not running.
  • Usage: Shows the number of currently active calls. E.g. Active (2/250) means that there are two active calls in the system. You need to refresh the web page to see current status. If there is a need to restart the system, one can wait until the Usage is Idle (0/250) not to interrupt any ongoing calls.
  • Current System Time: Shows the current time in the AlphaCom XE, as presented in display stations.
  • System Uptime: The time elapsed since last time the system (Linux) started
  • AMC Uptime: The time elapsed since last time the intercom application (AMCd) started
  • MAC Address: Shows the MAC address of the AlphaCom XE.
  • Total Space (FLASH / DATA FLASH / RAMS): Total memory space.
    • FLASH: Memory space for program files, such as Linux and all program modules (AMCd, SIPd, RMd, AlphaWeb etc.)
    • DATA FLASH: Memory space for storing of data, such as log files, voice messages and billing data (Not program files)
    • RAMFS: RAM File System for storing of temporary data, such as package uploads, web work files, RM- M100- and Billing configuration, various status data.
  • Free Space (FLASH / DATA FLASH / RAMS): Available memory space.
  • Battery Valid: The state data is stored in RAM memory on the AMC-IP, which is backed up by a battery. Yes means the battery is good, No means the battery must be replaced.


SW Configuration

Shows the version number of the different software modules.

  • AMC System Package: All AMC related software, including AlphaWeb and Billing
  • AMC Board Support Package: Linux system files, libraries, webserver etc.
  • Customer Database: The NVRAM version.


HW Configuration

Shows which boards are currently installed, their status and software revision.

Processes

Running software processes

Shows which software processes are currently running, and the version number of each process.

Stations

Stations - Configured
View Stations - Unconfigured

The table can be sorted by clicking on the relevant header. In the Search field you can search for any free text, e.g. directory number, display text or IP address.

  • Physical Numbers: The physical number is the physical port where an analog station is connected, or a virtual port when using IP station or SIP station.
  • Directory Number: The directory number is the number you must dial to reach the station.
  • Display Text: The caller ID of the station as programmed in AlphaPro, Users & Stations.
  • IP Address: The IP address of the IP Station or SIP Station. Clicking on the IP address will open a new tab in your browser and connect to that IP address.
  • MAC Address: This field is relevant for IP stations and SIP stations only.
    • (0013cb00c7e9): The MAC address of the IP station. When the MAC address is displayed in brackets with lowercase letters, the station is registered with Directory Number. The MAC address will only show when the station is registered, else it will show DIP free MAC.
    • 0013CB00C7E9: The MAC address of the IP station. When the MAC address is displayed without brackets in uppercase letters, the station is configured in AlphaPro to register with its MAC address. The MAC address will show regardless if the station is registered or not.
    • DIP free MAC: The IP station is configured in AlphaPro to register with Directory Number, but is not registered.
    • SIP Station: The station is configured as a SIP Station in AlphaPro.
  • Status
    • Station OK: The station is connected and reported OK in the AlphaCom system.
    • No Station: An ASLT line card is present, but no station is found.
    • Station Failure: The station has been registered to the Alphacom, but connection is now lost.
    • Not Registered: The IP station or SIP station is configured in the system, but has not been able to register to the AlphaCom.
    • Registered: The IP station or SIP station has successfully registered to the AlphaCom.
    • No License: The registration was rejected due to missing licenses.
  • Type: Shows what type of equipment which is connected/registered.
    • Analog stations is shown as 0
    • IP Stations - Shows which type of IP station
      • 8020 - Dual Display Stations
      • 8022 - Sub Stations
      • 8023 - Flush Master Stations
      • 8024 - Desk Master Stations
      • 8026 - IP ARIO
      • 100 - SIP Phone/Station
  • SW Ver: Software Version. Shows the IP station software version. Applicable to IP stations only.
  • HW Rev: Hardware Revision. Shows the IP station hardware version. Applicable to IP stations only.
  • Reg Time: Registration Time. Shows the last time the station registered to the AlphaCom.
  • Reg Count: Registration Counter. Shows the number of times a station has registered to the Alphacom since last reset.
  • MC: MultiCast. Status information about Group Audio configuration (Groupcall, Audio Program, Simplex Conference) and status of the IP station.
    • UC: Unicast
    • M0 or M1: Direct multicast on ethernet ports 0 or 1
    • R0 to R4: Relayed multicast to Group 0 to 4
See Multicast in AlphaCom for more details.



AlphaNet

AlphaNet

This tab gives an overview over the AlphaNet. The list is ascending according to the Node number. The list will show:

  • The Node Number
  • The Node Name
  • The Node Type
    • 2 = AlphaCom E
    • 3 = SIP node
  • Software Version (AMC sowftare version on the nodes AMC-IP card).
  • The Node IP Address
  • Status (Shows the communication state to the other Nodes in the AlphaNet.


Audio Statistics

Audio Connections

RTP statistics in Alphanet


Logging

Log Monitoring Window

Logging can be setup to:

  • Serial ports
  • Local file on AMC-IP
  • Syslog
  • E-mail
  • SNMP trap (MIB II)
  • Or to all above simultaneously

Three different log types are available:

-Low level DP messages (like in TST error buffer)<br\>-Messages from amcd, rtpd, amc_initd, amc_netconfig, kern, daemons
-RCI activations, error reports, log port, AlphaPro IP login<br\>-Amcd user, log and events
-All logins and authentications of users, stations, admin’s...<br\>-All converstations (start - end)

No log-streams are default. It must be configured in System configuration/Logging. Deletion is also done here.

”Pri Level” is only available for the technical log (info = all).

Syslog is a standard for sending log-information over Ethernet.

On-board logs are viewed in System Monitoring/logging.


System Configuration

Interfaces

IP settings
IP System Status
Apply

Program the ethernet interfaces and the subnet mask

After ”Save”, press ”Apply” to activate changes


Routes

When is IP routing required? The IP Routing table of the AlphaCom must be configured if there is a need to communicate with a device outside its own subnet. A “device” could be another AlphaCom, a PC (AlphaPro, AlphaWeb, SysLog), SIP equipment, Ethernet to Serial device etc. If the AlphaCom and the device do belong to the same subnet, it is no need to specify any routing information


Filters

Firewall Settings
Add a new protocol

The Filter is the AlphaCom's own firewall and must be configured when adding equioment that is supposed to communicate with the AlphaCom. Applications port number can be enabled on both ethernet ports. All ports except port 80 and 443 (AlphaWeb) can be deleted

And new application port numbers can be added. Remember to enable it after adding!


Logging

Log Configurations
Log Test
AMC System File Storage

There are three different log types:

  • System Log
    • RCI activations, error reports, log port, AlphaPro IP login
    • Amcd user, log and events
  • Call Statistics Log
    • All logins and authentications of users, stations, administrators...
    • All conversations (start - end)
  • Debug Log
    • Low level messages (like in TST error buffer)
    • Messages from amcd, rtpd, amc_initd, amc_netconfig, kern, daemons. For debugging purposes for software engineers.

The log information can be sent to:

  • Serial ports
  • Local file on AMC-IP
  • SysLog
  • Email
  • SNMP trap (MIB II)
  • Or to all above simultaneously


Storage:
The log files can total up to about 2MB. When the log is getting full, it will automatically start to delete the oldest file entries to make necessary room for new entries. A low traffic system, with no or little system messages can sustain log messages for many years.


License Key

License Configuration
License Key
New License Key

Licences for IP AlphaNet, IP stations and SIP audio links are added in System configuration/License Key. License Key is linked to the unique MAC address of the AMC

From AMC10.0.5 it is not necessary to configure audio routing because dynamic is default.

  • The exception is 2 line static license

AlphaNet, Multi-module and SIP licenses is in a pool.

  • All links without Net-Audio and Net-Routing are assumed to be Multi-module
  • If a static audio route is configured, it is taken out of the pool

”Currently used” shows links in use at the moment. ”Rejections” count up how many operations that are rejected due to no more available licenses.


User Management

User Management Form

It is highly recommended to change username and password. This is done in System configuration/User management


Time and Date

Current Time And Zone
Set New Timezone
Set Local Time
Configure Network Time Protocol (NTP) Server

The real-time clock in AlphaCom can be synchronised to a Network Time Protocol (NTP) server. This is set up in System configuration -> Time manager.

The button "Get Time" will read the NTP time and set the AMC realtime clock.

The clock is automatically syncronized once an hour (20 minutes past hour).



Hostnames

Configure Host Names
Add A New Host Name
Config File


Messaging

Only for black (AMC11) AMC-IP boards.

Messaging


High Availability

Only for black (AMC11) AMC-IP boards.

High Availability
High Availability Configuration
High Availability Status


System Upgrade

Package Info
Upload File
Package Info after Uploading New File

AMC software is upgraded in System upgrade.

Browse for the new software and do an upload to AMC-IP.

Then do a ”Select” and ”Install Selected”

For details se AMC-IP software upgrade

See also AlphaCom E Software packages


IP Station Upgrade

IP Station Upgrade Parameters
IP Stations List
IP Station Discover Parameters

IP Station Discovery:
To search for IP Stations in the range 10.5.101.100 to 10.5.101.200, enter:

  • Class C Network: 10.5.101
  • Subnet Start: 100
  • Subnet End: 200

A list of stations will appear when the search is finnished. By clicking on the IP address in the list you will be connected to the web server of that station.


Custom Scripts

Upload and Test Scripts:

Custom Scripts Configuration
Repository Custom Scripts
Upload File

The Custom Scripts allows end users to make and upload their own web pages and php scripts. These scripts will typically implement 'Click to Call' applications.

See the AlphaWeb Custom Scripts page for details.


Script Security Configuration:

User Access
Host Access
Config File

The Custom Scripts allows end users to make and upload their own web pages and php scripts. These scripts will typically implement 'Click to Call' applications.

See the AlphaWeb Custom Scripts page for details.


System Maintenance

Config Backup

AMC Backup File
Upload File

This is performed in System Maintenance/config backup

”Backup” in the Action-field will update backup.bin in AMC.

Click on the backup.bin to save the file to PC/server.

Browse for backup.bin and do upload and restore for restoring the backup.

See also: Backup


System Recovery

System Recovery


External Systems

RingMaster

RMD Config Pages


General Parameters:

General Parameters


Trunks:

Trunks


Call Numbers:

Call Numbers


Global Groups:

Global Groups


Privacy Links:

Privacy Links


Call Request Groups:

Call Request Groups


Help

About

About



AlphaWeb Technical

AlphaWeb uses an Apache/PHP Server. For more information about Apache visit Apache.org. For more information about PHP visit PHP.net.

  • XML Configuration file
  • Supports any standard WEB-browser with JavaScript enabled: Internet Explorer, Mozilla Firefox etc.
  • Recommended screen resolution 1024x768 or more. Lesser resolution will work, but layout may be affected.

AlphaWeb2.jpg

From AlphaSystem package alpha_sys_10_22 secure http transfer (https) are added. The https port 443 has to be opened in AlphaWeb before https is activated.

When activated you will get two options from the main login page in AlphaWeb:

[Login] Secure AlphaWeb (https)
[Login] Unsecure AlphaWeb (http)

Zenitel are not registered on any server as a 'Certifcate Authority' and thus you will get a warning from the browser. The process of accepting the Certificate is a bit different for different browsers, but in general you need to say you trust Zenitel Root CA as Cerificate isssuer.

IE7:

You will get the warning:
There is a problem with this website's security certificate.
* Choose Continue to this website (not recommended). * Give the standard login credentials. * Click on the 'Certificate Error' button on the top line in the explorer window. * View Certificates * Install Certificate??? - Note! Can't find entry for accepring Certifcate Authority again!?

Firefox:

You get a warning box:
* Choose 'Accept this certificate permanently' * Login