Difference between revisions of "Dynamic group call"
From Zenitel Wiki
(→Programming) |
m (→Operation (CRM IV and CRM V)) |
||
Line 2: | Line 2: | ||
*Press a dedicated "Group Config." [[DAK]] key. The red led in key starts flashing | *Press a dedicated "Group Config." [[DAK]] key. The red led in key starts flashing | ||
*Select subscribers to be included/excluded (toggle function) by pressing the assosiated [[DAK]] keys. A flashing green led in the keys indicates that the stations are included | *Select subscribers to be included/excluded (toggle function) by pressing the assosiated [[DAK]] keys. A flashing green led in the keys indicates that the stations are included | ||
− | *Press the "Group Config." button again, the [[Groups#Group_Call.2FAnnouncements|group call]] is now activated. The red led in the [[DAK]] key stops flashing | + | *Press the "Group Config." button again, the [[Groups#Group_Call.2FAnnouncements|group call]] is now activated. The red led in the [[DAK]] key stops flashing. Now the group call is activated and pressing the `M`-key opens the microphone. |
*The green leds continue to flash during the [[Groups#Group_Call.2FAnnouncements|group call]] | *The green leds continue to flash during the [[Groups#Group_Call.2FAnnouncements|group call]] | ||
− | *Cancel the [[Groups#Group_Call.2FAnnouncements|group call]]. All members will be removed, and the green leds stop flashing | + | *Cancel the [[Groups#Group_Call.2FAnnouncements|group call]] by pressing the `C`-key. All members will be removed from the group, and the green leds stop flashing. |
It is not neccessary to use [[Control Room Master IV|CRM-IV]] or [[IP Flush Master - 1008031000|CRM V]] stations, but with regular stations you will not get LED feedback on [[Groups#Group_Call.2FAnnouncements|group call]] inclusion/exclusion. | It is not neccessary to use [[Control Room Master IV|CRM-IV]] or [[IP Flush Master - 1008031000|CRM V]] stations, but with regular stations you will not get LED feedback on [[Groups#Group_Call.2FAnnouncements|group call]] inclusion/exclusion. |
Revision as of 05:32, 18 February 2010
Operation (CRM IV and CRM V)
- Press a dedicated "Group Config." DAK key. The red led in key starts flashing
- Select subscribers to be included/excluded (toggle function) by pressing the assosiated DAK keys. A flashing green led in the keys indicates that the stations are included
- Press the "Group Config." button again, the group call is now activated. The red led in the DAK key stops flashing. Now the group call is activated and pressing the `M`-key opens the microphone.
- The green leds continue to flash during the group call
- Cancel the group call by pressing the `C`-key. All members will be removed from the group, and the green leds stop flashing.
It is not neccessary to use CRM-IV or CRM V stations, but with regular stations you will not get LED feedback on group call inclusion/exclusion.
LIMITATION: You can only include subscribers, you cannot include groups!
Programming
- Software requirement: AMC 8.26 or later
- In AlphaPro, Directory & Features, create a directory number, feature 95/0. Directory number 9535 is included by default. Program the "Group Config." DAK button to 9535.
- Each CRM station must “own” a group call that nobody else uses. The directory number of the group call must be changed so that the two last digits are identical to the group index number. Example:
- Group 2 = 8502
- Group 10 = 8510
- Enter the group call directory number in the User Defined Parameter (%1.EXP) field of the CRM-IV. In AlphaPro, Users & Stations -> UDP -> User Defined Parameter (%1.EXP).
- Put all CRM’s that should have Dynamic group call feature in UDP group 1.
Event Handler configuration
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events:
Event 1
Event Owner: | Stations w/ UDP Id: 1 (The CRM stations) |
Event type: | 15 – Event Trigger |
Subevent: | 0 |
When change to: | ON or OFF |
When related to: | Directory Number, Id: 9535 |
Action: | IND %1.phy %1.dak(I%2.dir) 1 3 |
Event 2
Event Owner: | Stations w/ UDP, Id: 1 (The CRM stations) |
Event type: | 25 – Event trigger with parameter |
Subevent: | 0 |
When change to: | ON or OFF |
When related to: | All |
Action: | IF %sgm(%2.phy,%1.exp(2)) |
IND %1.phy %1.dak(I%2.dir) 2 3 OFF | |
ENDIF | |
IF %op(%sgm(%2.phy,%1.exp(2)),=,0) | |
IND %1.phy %1.dak(I%2.dir) 2 3 ON | |
ENDIF | |
$GRM L%2.dir NG%1.exp(2) U2 | |
IF %op(%2.dir,=,9535) | |
$DISCON_ST L%1.dir 0 | |
IND %1.phy %1.dak(I%2.dir) 2 3 OFF | |
PAUSE | |
PAUSE | |
PAUSE | |
$DD L%1.dir L%1.exp | |
ENDIF |
Event 3
Event Owner: | Stations w/ UDP, Id: 1 (The CRM stations) |
Event type: | 08 – Conversation - Outgoing |
Subevent: | 0 |
When change to: | OFF |
When related to: | All |
Action: | IF %op(%2.dir,=,%1.exp) |
IF %gns(%1.exp(2),0) | |
$ER U15 U1 U1 U1 N%gns(%1.exp(2),0) U3 %1.ref | |
ENDIF | |
ENDIF |
Event 4
Event Owner: | Stations w/ UDP, Id: 8 (All stations) |
Event type: | 15 – Event Trigger |
Subevent: | 1 (NOTE: Subtype 1, NOT 0) |
When change to: | ON |
When related to: | All |
Action: | $GRM N%gns(%2.exp(2),0) NG %2.exp(2) U0 |
IND %2.phy %2.dak(I%1.dir) 2 3 OFF | |
PAUSE | |
IF %gns(%2.exp(2),0) | |
$ER U15 U1 U1 U1 N%gns(%2.exp(2),0) U3 %2.ref | |
ENDIF |